I want to search for...
Permit #2015100163
Permit Details
Status: COED
| Parcel Id: 07-11-31-7011-RP A -0020 |
| Block: RP A |
| Subdivision: - |
| Job Phone: (386) 547-0409 |
| Location Address: 1490 PALM COAST PKWY NW |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 11/02/2015 |
| NOC: RECORDED |
| Applicant name: BOHDAN HAWRYLUK |
| Owner: MATUSZCZAK MICHAEL E |
|
Address 15 CHICKASAW COURT PALM COAST, FL 32137 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤7,200.00 |
| Job Description: UNIT #3 - INTERIOR ALTERATION FOR "EMERALD DAY SPA" |
| Type: CN |
Contractor
INTERCOASTAL CONSTRUCTION CO.
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
14 SLIPPER ORCHID TRAIL EAST PALM COAST, FL 32164 |
CBC035048 (Exp: 08/31/2024) | (386) 547-0409 | 386-673-8868 |
Sub Contractors
GREGORY ALLEN HENRY
| Status | Location Address | State License Number | Phone |
| CANCEL |
1332 SUNSET BLVD DAYTONA BEACH, FL 32117 |
ER13015005 (Exp: 08/31/2020) | 386-679-6908 |
JOHN ROBERT LONGFRITZ
| Status | Location Address | State License Number | Phone |
| CANCEL |
1323 10TH ST HOLLY HILL, FL 32117 |
CFC057901 (Exp: 08/31/2022) | 386-258-7316 |
Inspection History
| Type | Request Date | Result | Inspector |
| BUILDING FINAL | 12/21/2015 | FINAL APPROVED | CMINI |
| FIRE FINAL | 12/21/2015 | APPROVED | JHINDMAN |
| U - UTILITY COMMERCIAL FINAL | 12/21/2015 | FINAL APPROVED | MBACON |
| ABOVE CEILING | 12/18/2015 | APPROVED | CMINI |
| PLUMBING FINAL | 12/18/2015 | APPROVED | CMINI |
| ELECTRIC FINAL | 12/18/2015 | FINAL APPROVED | RMARTIN |
| FRAMING | 11/20/2015 | APPROVED | CMINI |
| ELECTRIC 2ND ROUGH | 11/20/2015 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 11/20/2015 2:53:21 PM ELECTRIC REVISIONS NEEDED BY FINAL | |||
| PLUMBING 2ND ROUGH | 11/20/2015 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 11/20/2015 2:53:21 PM PLUMBING REVISION NEEDED BY FINAL |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 12/16/2015 | 12/17/2015 |
| BLD | COMPLETE | 12/04/2015 | 12/08/2015 |
| Note: Revision- Added metal stud wall 42 inch high between hair drying area and styling station. | |||
| ELEC | HOLD | 12/04/2015 | 12/07/2015 |
| Note: Please provide a disconnect for water heater per NEC 2011 Article 440.14. -DC. Rewis 986-4736 | |||
| FI1 | COMPLETE | 12/04/2015 | 12/14/2015 |
| PLUM | COMPLETE | 12/04/2015 | 12/08/2015 |
| Note: Not applicable | |||
| ZON | COMPLETE | 12/04/2015 | 12/04/2015 |
| BLD | COMPLETE | 10/29/2015 | 10/29/2015 |
| PLUM | COMPLETE | 10/29/2015 | 10/29/2015 |
| MECH | COMPLETE | 10/29/2015 | 10/29/2015 |
| BLD | HOLD | 10/22/2015 | 10/22/2015 |
| Note: 1. Provide plan design code is not the currently adopted code. 5th edition of the Florida Building code. (2014). J. Hindman. 986-3784. | |||
| ELEC | COMPLETE | 10/22/2015 | 10/22/2015 |
| PLUM | HOLD | 10/22/2015 | 10/23/2015 |
| Note: Previous comment shall be addressed. Provide sanitary line tie-in connection of the new sinks shown on sanitary riser diagram for continuity flow per FBC 5th ed. 107.2.1. F.N. Reodica -386-986-4734. Please note the sanitary drain shows closed loop (no connection to any existing pipe). | |||
| MECH | HOLD | 10/22/2015 | 10/23/2015 |
| Note: 1. Provide hvac plan showing supply and return air for tanning room and kitchen as both spaces have full height partition based on revised plan per FBCM 5th edition 601. 2. Provide updated reference code to FBCM 5th edition (2014) as previously requested. F.N. Reodica- 386-986-4734. - | |||
| MECH | HOLD | 10/13/2015 | 10/13/2015 |
| Note: Previous comment shall be addressed. 1. Provide hvac plan to determine if the proposed space conversion from hair salon to hair and nail salon complies with the ventilation requirement and source capture system per FBCM 5th ed. 403.2.1(3). 2. Provide updated reference code to FBCM 5th edition (2014). F.N. Reodica- 386-986-4734. | |||
| PLUM | HOLD | 10/12/2015 | 10/13/2015 |
| Note: Provide sanitary line tie-in connection of the new sinks shown on sanitary riser diagram for continuity flow per FBC 5th ed. 107.2.1. F.N. Reodica -386-986-4734. | |||
| MECH | HOLD | 10/07/2015 | 10/07/2015 |
| Note: 1. Provide hvac plan to determine if the proposed space conversion from hair salon to hair and nail salon complies with the ventilation requirement and source capture system per FBCM 5th ed. 403.2.1(3). 2. Provide updated reference code to FBCM 5th edition (2014). F.N. Reodica- 386-986-4734. | |||
| PLUM | HOLD | 10/07/2015 | 10/07/2015 |
| Note: Provide plumbing plan, sanitary and domestic water riser diagrams, and equipment and piping material specifications per FBC 5th ed. 107.3.5. F.N. Reodica -386-986-4734. | |||
| UD1 | COMPLETE | 10/07/2015 | 10/07/2015 |
| ZON | COMPLETE | 10/07/2015 | 10/07/2015 |
| BLD | HOLD | 10/07/2015 | 10/08/2015 |
| Note: 1. Provide a typical wall section. 5th ed. FBC 107.3.5. J. Hindman 986-3784. | |||
| ELEC | HOLD | 10/07/2015 | 10/08/2015 |
| Note: Please provide panel clearance from door opening in massage room per NEC 2011 Article 110.26. Please provide disconnect for water heater per NEC 2011 Article 422.30. -DC. Rewis 986-4736 | |||
| FI1 | COMPLETE | 10/07/2015 | 10/07/2015 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 12/17/2015 |
| SITE PLAN 20 | ¤20.00 | 11/02/2015 |
| SURCHARGE FS 533.721 | ¤4.34 | 11/02/2015 |
| SURCHARGE - FS 468.631 | ¤4.34 | 11/02/2015 |
| ADMIN COMMERCIAL | ¤60.00 | 11/02/2015 |
| INSPECTION - COMMERCIAL ADD | ¤56.00 | 11/02/2015 |
| ELECTRIC FEE | ¤64.80 | 11/02/2015 |
| FIRE PLANS REVIEW | ¤25.00 | 11/02/2015 |
| PLAN CHECK FEE | ¤100.00 | 11/02/2015 |
| PLUMBING FEE | ¤64.80 | 11/02/2015 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤439.28 |