I want to search for...
Permit #2015100843
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-00440-0040 |
| CONDITIONED SPACE: 2427 sqft |
| GARAGE: 575 sqft |
| OPENED PORCH (WITH ROOF) : 180 sqft |
| OPENED PORCH (WITH ROOF) : 19 sqft |
| Total Square Footage: 3201 sqft |
| Block: 00440 |
| Subdivision: 2176 - SECTION 37-LAKEVIEW |
| Job Phone: 904-268-7730 |
| Location Address: 22 LANCASTER LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/19/2016 |
| NOC: RECORDED |
| Applicant name: KENNETH WAYNE CAMPBELL JR |
| Owner: MARONDA HOMES, INC OF FLORIDA |
|
Address 9700 PHILIPS HIGHWAY JACKSONVILLE, FL 32256 |
|
Address SUITE 102 JACKSONVILLE, FL 32256 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤121,026.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MARONDA HOMES INC. OF FLORIDA
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
6800 SOUTHPOINT PKWAY SUITE 300 JACKSONVILLE, FL 32216 |
CBC058803 (Exp: 08/31/2018) | 904-268-7730 | 904-268-7740 |
Sub Contractors
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
DEBORAH MAXINE JACKSON
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
9474 OLD PLANK RD JACKSONVILLE , FL 32220 |
CCC1328530 (Exp: 08/31/2016) | 904-435-7663 | 904-404-8406 |
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 07/22/2016 | FINAL APPROVED | JNICHOLS |
| ROW FINAL | 07/21/2016 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION. APPROVED | |||
| BLD - BUILDING FINAL | 07/21/2016 | FINAL APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 07/15/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: need address on house.....need to fix grass damaged by dumpster......need to adjust self closing door.....need city stamped final survey on site at time of inspection. not ready. | |||
| ROW FINAL | 07/15/2016 | Disapproved -FEE REQUIRED | CTROHA |
| Note: GERNERAL CLEAN UP: CLEAN UP ALL TRASH ALONG LSPL IN ADJ LOT ALSO SWALE OF ADJ LOT CLEAN OUT CULVERT ENDS | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | 07/07/2016 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION. CORRECTIONS MADE. APPROVED | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | 07/06/2016 | Disapproved -FEE REQUIRED | CTROHA |
| Note: THIS IS A REINSPECTION MISSING DOCUMENTS: FINAL SURVEY REQUIRED | |||
| FINAL SURVEY (OFFICE USE ONLY) | 07/06/2016 | APPROVED | DREWIS |
| ELECTRIC - EARLY POWER | 07/05/2016 | APPROVED | JCOLASANTI |
| Note: Inspection Resulted at 7/5/2016 3:14:47 PM SPOKE WITH SUSAN AT FPL TO RELEASE POWER | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | 07/05/2016 | Disapproved -FEE REQUIRED | RGROSS |
| Note: CLEAN OUT CULVERT ENDS, INCUDING DRIED CONCRETE. | |||
| U - SEWER TIE IN | 06/17/2016 | APPROVED | JNICHOLS |
| PRE-APRON (PRE-POUR/DRIVEWAY) | 06/03/2016 | APPROVED - AS NOTED | GLALIMA |
| Note: WORKING ON THE CENTER LINE OF CULVERT PIPE 10' ON RIGHT AND 2' ON LEFT READY TO POUR | |||
| LATH/BRICK/ WATER BARRIER | 05/09/2016 | APPROVED | JCOLASANTI |
| INSULATION | 05/02/2016 | APPROVED | JCOLASANTI |
| ALL ROUGH | 04/27/2016 | APPROVED - AS NOTED | JCOLASANTI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/27/2016 10:18:20 AM NEED NAIL PLATES ON SECURITY WIRE. CODE READS ALL WIRE NAIL PLATES ON ELECTRIC NEC.300.4 | |||
| GRAVITY SEWER TEST | 04/27/2016 | APPROVED | JCOLASANTI |
| ALL ROUGH | 04/26/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 4/26/2016 3:30:30 PM NEED TO ADD OUTLET 3`` AT KITCHEN ADJACENT TO BEDROOM, NEED MORE WATERIN 10`` PIPE TO PROPERLY TEST DWV. NEED NAIL PLATE ON SECURITY WIRE. NEED TO MAKE SURE FLOOR OUTLET CONDUCTOR IS RATED FOR UNDERGROUND USAGE. (MOST TIMES GREY WIRE, NO INDENTIFICATION ON INSTALLED WIRE. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/06/2016 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 4/6/2016 11:49:24 AM ALL OK, STRAP THAT IS NOT NAILED ON FRONT RIGHT EXTERIOR WALL IS REPLACED BY A MTS 20 ON THE INSIDE, PLEASE NAIL STRAP ANYWAY | |||
| TIE BEAM / LINTEL | 03/22/2016 | APPROVED | JCOLASANTI |
| MONOLITHIC SLAB | 03/14/2016 | APPROVED | JCOLASANTI |
| FOUND SURVEY APPROVED (OFFICE) | 03/09/2016 | APPROVED | DREWIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 03/07/2016 | APPROVED | JCOLASANTI |
| FOOTER | 02/16/2016 | APPROVED | JCOLASANTI |
| Note: per contractor |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 07/06/2016 | 07/06/2016 |
| Note: Released By: DREWIS final s | |||
| ZON | COMPLETE | 01/07/2016 | 01/08/2016 |
| ELEC | COMPLETE | 12/14/2015 | 12/14/2015 |
| ZON | HOLD | 12/14/2015 | 12/15/2015 |
| Note: 1. Site plan must depict A/C pad and include its dimensions and setbacks. 2. Unable to verify that exterior house color is an earty tone with the information provided on Color and Material Sheet. Please provide paint color sample.T. Childs 986-2473 | |||
| UD1 | COMPLETE | 12/14/2015 | 12/14/2015 |
| Note: see the notes | |||
| ELEC | HOLD | 11/30/2015 | 12/01/2015 |
| Note: Please provide a disconnect for condensing unit per NEC 2011 Article 440.14 -DC. Rewis 986-4736 | |||
| BLD | COMPLETE | 11/30/2015 | 12/03/2015 |
| PLUM | COMPLETE | 11/30/2015 | 12/02/2015 |
| ZON | HOLD | 11/30/2015 | 12/02/2015 |
| Note: REPEAT COMMENTS: 1. Site plan must depict A/C pad and include its dimensions and setbacks. 2. Color sheet must depict paint manufacturer and color #. (Email has been sent to campbellke@maronda.com that includes the updated Color and Material Sheet for single family residential permit submittals). T. Childs 986-2473 | |||
| ENGIN1 | COMPLETE | 11/30/2015 | 12/01/2015 |
| SW1 | COMPLETE | 11/30/2015 | 12/01/2015 |
| UD1 | HOLD | 11/30/2015 | 12/03/2015 |
| Note: PEP Panel is not shown in the electrical plan. Submit a new electrical plan showing PEP Panel on the building on the same side of the building as indicated in the Utility marked site plan. | |||
| URB | COMPLETE | 11/30/2015 | 12/01/2015 |
| BLD | HOLD | 11/02/2015 | 11/02/2015 |
| Note: 1. Provide a roof underlayment that complies with 5th ed. FBC R 905.2.7. J. Hindman 986-3784. | |||
| ELEC | HOLD | 11/02/2015 | 11/02/2015 |
| Note: Please provide load calculations and electrical riser diagram. Please add or move receptacles in all bedrooms, great room and flex space to meet NEC 2011 Article 210.52. Please provide a disconnect for outside A/C unit per NEC 2011 Article 440.14. -DC. Rewis 9864736 | |||
| ENGIN1 | COMPLETE | 11/02/2015 | 11/10/2015 |
| MECH | COMPLETE | 11/02/2015 | 11/02/2015 |
| PLUM | HOLD | 11/02/2015 | 11/02/2015 |
| Note: Provide sanitary riser diagram either prepared by design professional or plumbing contractor with signature and license number per FBC 5th edition 107.2.1. | |||
| SW1 | COMPLETE | 11/02/2015 | 11/02/2015 |
| UD1 | COMPLETE | 11/02/2015 | 11/06/2015 |
| Note: See Notes | |||
| ZON | HOLD | 11/02/2015 | 11/03/2015 |
| Note: 1. Site plan must depict A/C pad and include its dimensions and setbacks. 2. Landscape plan must depict A/C equipment and show that it is properly screened. 3. Landscape plan must depict that irrigation is being installed since St. Augustine sod is being used. 4. Color sheet must depict paint manufacturer and color #. (Email has been sent to campbellke@maronda.com that includes the updated Color and Material Sheet for single family residential permit submittals). T. Childs 986-2473 | |||
| URB | COMPLETE | 11/02/2015 | 11/02/2015 |
| SW1 | COMPLETE | 03/09/2016 | |
| Note: Released By: DREWIS |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 07/21/2016 |
| REINSPECTION FEE | ¤40.00 | 07/21/2016 |
| REINSPECTION FEE | ¤40.00 | 07/19/2016 |
| REINSPECTION FEE | ¤40.00 | 07/19/2016 |
| REINSPECTION FEE | ¤40.00 | 07/19/2016 |
| NEW RESIDENTIAL INSPECTIONS | ¤602.00 | 01/19/2016 |
| SITE PLAN 20 | ¤20.00 | 01/19/2016 |
| SURCHARGE FS 533.721 | ¤21.96 | 01/19/2016 |
| SURCHARGE - FS 468.631 | ¤21.96 | 01/19/2016 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/19/2016 |
| 3% TRANS IMPACT FEE CREDIT | (¤91.51) | 01/19/2016 |
| ADMIN FEE | ¤20.00 | 01/19/2016 |
| ELECTRIC FEE | ¤240.60 | 01/19/2016 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.38) | 01/19/2016 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤212.80 | 01/19/2016 |
| IMPACT FEE PARKS | ¤849.24 | 01/19/2016 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 01/19/2016 |
| IMPACT FEE TRANSPORTATION | ¤3,050.24 | 01/19/2016 |
| MECHANICAL FEE | ¤240.60 | 01/19/2016 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 01/19/2016 |
| PLAN CHECK FEE | ¤120.40 | 01/19/2016 |
| PLUMBING FEE | ¤240.60 | 01/19/2016 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,397.03 |