I want to search for...

Permit #2015110499

Permit Details

Status: COED

Parcel Id: 07-11-31-7027-00470-0070
CONDITIONED SPACE: 2427 sqft
GARAGE: 575 sqft
OPENED PORCH (WITH ROOF) : 180 sqft
OPENED PORCH (WITH ROOF) : 19 sqft
Total Square Footage: 3201 sqft
Block: 00470
Subdivision: 2128 - SECTION 27-WYNNFIELD
Job Phone: 904-268-7730
Location Address: 23 WOOD CLIFT LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/21/2016
NOC: RECORDED
Applicant name: KENNETH WAYNE CAMPBELL JR
Owner: MARONDA HOMES INC

Address

9700 PHILIPS HWY

JACKSONVILLE,, FL 32256

Address

SUITE 102

JACKSONVILLE,, FL 32256

Lot: 0070
Contracted Stated Job Value: ¤121,426.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MARONDA HOMES INC. OF FLORIDA
Status Location Address State License Number Phone Fax
CANCEL

6800 SOUTHPOINT PKWAY SUITE 300

JACKSONVILLE, FL 32216

CBC058803 (Exp: 08/31/2018) 904-268-7730 904-268-7740

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
ROBERT G DELLO RUSSO
Status Location Address State License Number Phone Fax
DECEASED

531 CODISCO WAY

SANFORD, FL 32771

CAC032448 (Exp: 08/31/2022) (407)831-2665 (407)333-3853
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
DEBORAH MAXINE JACKSON
Status Location Address State License Number Phone Fax
CANCEL

9474 OLD PLANK RD

JACKSONVILLE , FL 32220

CCC1328530 (Exp: 08/31/2016) 904-435-7663 904-404-8406
JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 07/22/2016 FINAL APPROVED JNICHOLS
BLD - BUILDING FINAL 07/21/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: THIS IS A REINSPECTION Inspection Resulted at 7/21/2016 11:47:41 AM NEED TO ADJUST SELFCLOSING DOOR.....NEED LIGHT IN BEDROOMS OR SWITH OUTLET......MASTER BEDROOM BATHROOM RIGHT AND LAV HOT COLD NEED TO BE REVERSED.
BLD - BUILDING FINAL 07/21/2016 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 07/20/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: THIS IS A REINSPECTION doors locked need access to house to complete inspection
ROW FINAL 07/20/2016 APPROVED RGROSS
Note: THIS IS A REINSPECTION
ROW FINAL 07/15/2016 Disapproved -FEE REQUIRED CTROHA
Note: REMOVE DUMPSTER FROM SWALE AND SOD AREA
BLD - BUILDING FINAL 07/15/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: no paperwok on site
FINAL APRON (AFTER POUR/DRIVEWAY) 07/07/2016 APPROVED RGROSS
Note: THIS IS A REINSPECTION. APPROVED
FINAL APRON (AFTER POUR/DRIVEWAY) 07/06/2016 Disapproved -FEE REQUIRED CTROHA
Note: THIS IS A REINSPECTION MISSING DOCUMENTS: FINAL SURVEY IS REQUIRED
FINAL SURVEY (OFFICE USE ONLY) 07/06/2016 APPROVED DREWIS
ELECTRIC - EARLY POWER 07/06/2016 APPROVED JCOLASANTI
Note: Inspection Resulted at 7/6/2016 2:39:26 PM SPOKE WITH SUSAN AT FPL TO RELEASE POWER.
FINAL APRON (AFTER POUR/DRIVEWAY) 07/05/2016 Disapproved -FEE REQUIRED RGROSS
Note: CLEAN CULVERT ENDS.
U - SEWER TIE IN 06/17/2016 APPROVED MBACON
PRE-APRON (PRE-POUR/DRIVEWAY) 06/08/2016 APPROVED - AS NOTED CTROHA
Note: THIS IS A REINSPECTION IT IS THE BUILDERS RESPONIBILITY TO RECHECK ELEVATIONS PRIOR TO PLACEMENT OF CONCRETE
PRE-APRON (PRE-POUR/DRIVEWAY) 06/06/2016 Disapproved -FEE REQUIRED CTROHA
Note: THIS IS A REINSPECTION FULL OF WATER UNABLE TO DETERMINE GRADE OR COMPACTION PLEASE HAVE PORT-O-LET MOVED FROM SWALE IN CASE OF HEAVE RAINS TODAY THANK YOU
PRE-APRON (PRE-POUR/DRIVEWAY) 06/03/2016 Disapproved -FEE REQUIRED CTROHA
Note: NO BENCH MARK ON POLE ACCROSS THE STREET SEE PINK PAINT CULVERT PIPE NOT CENTERED IN DRIVEWAY SEE PINK PAINT AND PHOTOS
LATH/BRICK/ WATER BARRIER 05/09/2016 APPROVED JCOLASANTI
GRAVITY SEWER TEST 05/03/2016 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
GRAVITY SEWER TEST 05/02/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 5/2/2016 10:24:39 AM CONNECTION TO HOUSE IS COVERED, CANNOT REMOVE CAP ON CLEANOUT NEED TO SEE WATER IN PIPE.
INSULATION 04/29/2016 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
INSULATION 04/27/2016 Disapproved -FEE REQUIRED LMILLER
Note: Inspection Resulted at 4/27/2016 12:26:29 PM BAFFLES REQUIRED… IN ACCORDANCE WITH FBC ENERGY CONSERVATION R303.2.1 AND MANUFACTURER SPECS.(EXTERIOR WALLS, MASTER BEDROOM AS WELL AS MIDDLE AND BACK BEDROOMS
ALL ROUGH 04/20/2016 APPROVED - AS NOTED JCOLASANTI
Note: Inspection Resulted at 4/20/2016 1:10:27 PM NEED 10`` OF HEAD PRESURE(NOT ENOUGH WATER IN PIPE)....FIX FURING STRIPS, TWO PLACES GUEST BEDROOMS FOR CORRECT FIREBLOCK....MUST RIMOVE WIRES IN CONTACT WITH RECESS CAN LIGHTS NEC 310.10.. CHECK TO MAKE SURE SERVICE MAST IS 18" FROM LOOP TO ROOF...WILL CHECK AT INSULATION.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/11/2016 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/06/2016 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION Inspection Resulted at 4/6/2016 9:57:40 AM POUR DOWN CELL MARKED ON PLANS. DOWN CELLS R609.1.4, ALL CELLS CONTAINING REINFORCEMENT SHALL BE GROUTED SOLID
ROOF SHEATHING 03/31/2016 APPROVED JCOLASANTI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/31/2016 CANCELLED BY APPLICANT JCOLASANTI
TIE BEAM / LINTEL 03/22/2016 APPROVED JCOLASANTI
TIE BEAM / LINTEL 03/17/2016 CANCELLED BY APPLICANT AIRS WEB
FOUND SURVEY APPROVED (OFFICE) 03/09/2016 APPROVED DREWIS
MONOLITHIC SLAB 03/08/2016 APPROVED JCOLASANTI
PLUMBING 1ST ROUGH UNDERGROUND 03/03/2016 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 03/02/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 3/2/2016 9:53:00 AM TEST ON DWV AND WATER PIPPING TEST PIPE SHALL BE FILLED WITH WATER TO A POINT NOT LESS THAN 10’AND HELD UNDER TEST FOR A PERIOD OF 15 MIN. FPC .312 FBC 2503.5.1 (WATER LINE NEEDS TO BE TESTED WITH WATER, AIR NOT ALLOWED WITH PLASTIC PIPE, NEED WATER IN DWV PIPE.)
FOOTER 02/16/2016 APPROVED JCOLASANTI

Review History

Department Status Date In Date Out
SW1 HOLD 06/30/2016 07/01/2016
Note: Held By: DREWIS Swale stormwater flow does not match approved swale diagram. -DC. Rewis 986-4736
SW1 COMPLETE 03/09/2016 03/09/2016
Note: Released By: DREWIS foundation survey
ZON COMPLETE 01/13/2016 01/14/2016
ELEC COMPLETE 01/07/2016 01/08/2016
ZON HOLD 01/07/2016 01/08/2016
Note: Verify rear setback dimensions depicted on site plan.
ZON HOLD 12/11/2015 12/14/2015
Note: No color sample provided. Landscape site plan still shows different orientation than the other site plans.
ELEC HOLD 12/11/2015 12/11/2015
Note: Please provide load calculations for residence. -DC. Rewis 986-4736
BLD COMPLETE 11/19/2015 11/20/2015
ELEC HOLD 11/19/2015 11/19/2015
Note: Please provide load calculations for the residence. -DC. Rewis 9864736
ENGIN1 COMPLETE 11/19/2015 11/30/2015
MECH COMPLETE 11/19/2015 11/20/2015
PLUM COMPLETE 11/19/2015 11/20/2015
SW1 COMPLETE 11/19/2015 11/19/2015
UD1 COMPLETE 11/19/2015 11/23/2015
Note: see notes
ZON HOLD 11/19/2015 11/19/2015
Note: 1. Provide sample of exterior color. Unable to determine if it is an earth tone. 2. Site plan has different garage-side orientation than the landscape plan and the blueprints. Resubmit whichever is incorrect so that all are consistent with the proposed structure. T. Childs 986-2473
URB COMPLETE 11/19/2015 11/20/2015
SW1 COMPLETE 07/06/2016
Note: Released By: DREWIS

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 07/21/2016
REINSPECTION FEE ¤40.00 07/21/2016
REINSPECTION FEE ¤40.00 07/21/2016
REINSPECTION FEE ¤40.00 07/21/2016
REINSPECTION FEE ¤40.00 07/21/2016
REINSPECTION FEE ¤40.00 07/21/2016
REINSPECTION FEE ¤40.00 07/21/2016
REINSPECTION FEE ¤40.00 07/21/2016
REINSPECTION FEE ¤40.00 07/21/2016
REINSPECTION FEE ¤40.00 07/21/2016
REINSPECTION FEE ¤40.00 07/21/2016
REINSPECTION FEE ¤40.00 07/21/2016
ADDITIONAL FEE ¤200.00 07/21/2016
ADMIN FEE ¤20.00 01/21/2016
ELECTRIC FEE ¤240.60 01/21/2016
3% FIRE IMPACT FEE CREDIT (¤6.38) 01/21/2016
IMPACT FEE FIRE NONRESIDENTIAL ¤212.80 01/21/2016
IMPACT FEE PARKS ¤849.24 01/21/2016
IMPACT FEE SCHOOL ¤3,600.00 01/21/2016
IMPACT FEE TRANSPORTATION ¤3,124.67 01/21/2016
MECHANICAL FEE ¤240.60 01/21/2016
3% PARKS IMPACT FEE CREDIT (¤25.48) 01/21/2016
PLAN CHECK FEE ¤120.40 01/21/2016
PLUMBING FEE ¤240.60 01/21/2016
NEW RESIDENTIAL INSPECTIONS ¤602.00 01/21/2016
SITE PLAN 20 ¤20.00 01/21/2016
SURCHARGE FS 533.721 ¤21.96 01/21/2016
SURCHARGE - FS 468.631 ¤21.96 01/21/2016
STORM WATER PERMIT FEES ¤80.00 01/21/2016
3% TRANS IMPACT FEE CREDIT (¤93.74) 01/21/2016