Permit #2015120261

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7008-00050-0100
CONDITIONED SPACE: 68 sqft
Total Square Footage: 68 sqft
Block: 00050
Subdivision: 2204 - SECTION 8-COUNTRY CLUB COVE
Job Phone: 386-447-1402
Location Address: 27 COOPER LN
Type: BA - BUILDING ADDITION
Issue Date: 01/19/2016
NOC: RECORDED
Applicant name: RONALD ERIC PHILLIPS
Owner: SUNBLISS PROPERTIES LLC

Address

226 A ST JOE PLAZA DRIVE

PALM COAST, FL 32164

Address

SUITE #104

PALM COAST, FL 32164

Lot: 0100
Contracted Stated Job Value: ¤28,000.00
Job Description: PORCH REPAIR
Type: CN

Contractor

PHILLIPS COASTAL CONSTRUCTION, INC
Status Location Address State License Number Phone
CANCEL

58 BUTTERFIELD DRIVE

PALM COAST, FL 32137

CGC1506412 (Exp: 08/31/2024) 386-447-1402

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
PAUL S AIELLO
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 351926

PALM COAST, FL 32137

CAC1815808 (Exp: 08/31/2016) (386)239-0053 (386)323-1955
BARRY D MARTIN
Status Location Address State License Number Phone Fax
CANCEL

1650 N STATE STREET

Bunnell, FL 32110

CCC033728 (Exp: 08/31/2020) (386) 437-7700 (386)437-7701
HEATH EDWARD SANFORD
Status Location Address State License Number Phone Fax
ACTIVE

1351 HAZELNUT ST

BUNNELL, FL 32110

CFC1427527 (Exp: 08/31/2026) 386-445-2532 386-445-5575

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 06/27/2016 FINAL APPROVED JNICHOLS
BLD - BUILDING FINAL 06/24/2016 FINAL APPROVED CMINI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 06/07/2016 Disapproved -FEE REQUIRED LMILLER
Note: Inspection Resulted at 6/7/2016 3:31:14 PM HOLES IN CEILING MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 BUILDING THERMAL ENVELOPE, R402.4 1.1 AIR LEAKAGE (MANDATORY). INSTALLATION, R402.4, OPENINGS AND PENETRATIONS THROUGH WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL NOT BE PERMITTED FBC. R302.5 (SEAL BUILDING ENVELOPE).... GARAGE DOOR BUCKS NOT ATTACHED PER APPROVED PLANS.... EXTERIOR DOOR LIGHTS…. EACH EXTERIOR DOOR SHALL HAVE A LIGHT AND SWITCH R 3903.3.... (LASO MISSING EXTERIOR DOOR TRIM ON REAR DOOR).... GFCI OUTLET WALL OUTLET LEFT OF THE KITCHEN WILL NOT TRIP.... GFCI``S IN THE GARAGE DO NOT HAVE POWER AND ARE NOT SAFED OFF WITH OUTLET COVERS.
LATH/BRICK/ WATER BARRIER 03/03/2016 APPROVED DROCKWELL
ALL ROUGH 03/02/2016 APPROVED LMILLER
Note: THIS IS A REINSPECTION
INSULATION 03/02/2016 APPROVED LMILLER
ALL ROUGH 03/01/2016 Disapproved - NO FEE LMILLER
Note: THIS IS A REINSPECTION Inspection Resulted at 3/1/2016 1:51:26 PM NEED TO ADD A PLUMBING CONTRACTOR TO PERMIT PRIOR TO THIS INSPECTION (PAPERWORK PROVING ADDED PLUMBER MUST BE ON SITE AT TIME OF ALL ROUGH)
ALL ROUGH 02/26/2016 Disapproved - NO FEE LMILLER
Note: Inspection Resulted at 2/26/2016 1:49:20 PM NEED TO ADD A PLUMBING CONTRACTOR TO PERMIT PRIOR TO THIS INSPECTION
FRAMING 02/25/2016 APPROVED - AS NOTED LMILLER
Note: THIS IS A REINSPECTION Inspection Resulted at 2/25/2016 1:49:56 PM ADD AN ALL ROUGH INSPETCTION TO PERMIT AND CALL IT IN PRIOR TO INSULATION.
WALL SHEATHING 02/15/2016 APPROVED DROCKWELL
FRAMING 02/15/2016 PARTIALLY APPROVED DROCKWELL
Note: Inspection Resulted at 2/15/2016 9:34:49 AM GARAGE DOOR FRAMING SEPARATE
MONOLITHIC SLAB 01/21/2016 APPROVED CMINI

Review History

Department Status Date In Date Out
BLD COMPLETE 06/17/2016 06/17/2016
PLUM COMPLETE 02/22/2016 02/24/2016
Note: Revision - replace all plumbing fixtures in 2 bathrooms.
BLD COMPLETE 02/15/2016 02/17/2016
ELEC COMPLETE 02/15/2016 02/17/2016
PLUM HOLD 02/15/2016 02/15/2016
Note: Clarify the plumbing scope of work as description shows ALL plumbing fixtures to be replaced but plan shows water closets are not included. Coordinate for clarity per FBC 5th ed. 107.2.1. F.N. Reodica.-386-986-4734.
BLD COMPLETE 01/13/2016 01/14/2016
ELEC COMPLETE 01/13/2016 01/14/2016
ZON COMPLETE 01/13/2016 01/14/2016
ELEC COMPLETE 12/31/2015 01/04/2016
SW1 COMPLETE 12/31/2015 01/04/2016
BLD HOLD 12/31/2015 01/04/2016
Note: 1. On page 3/5 typical wall section Provide the correct ceiling insulation R value and provide the minimum roof underlayment (30 lb.) per the energy and roofing worksheets. 5th ed. FBC R 107.2.1. J. Hindman 986-3784.2nd request.
BLD HOLD 12/10/2015 12/16/2015
Note: 1. On page 3/5 typical wall section Provide the correct ceiling insulation R value and provide the minimum roof underlayment (30 lb.) per the energy and roofing worksheets. 5th ed. FBC R 107.2.1. J. Hindman 986-3784.
SW1 HOLD 12/10/2015 12/10/2015
Note: Please provide a site plan depicting positive storm water flow to easements in addition to set back measurements. -DC. Rewis 986-4736
ZON COMPLETE 12/10/2015 12/11/2015
ELEC HOLD 12/10/2015 12/10/2015
Note: Please up date to current code reference. Please provide a floor plan depicting receptacle locations. -DC. Rewis 986-4736
MECH COMPLETE 12/10/2015 12/16/2015

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REVISION ¤40.00 06/17/2016
REINSPECTION FEE ¤40.00 06/17/2016
CONTRACTOR CHANGE ¤40.00 06/06/2016
REVISION ¤40.00 02/24/2016
REVISION ¤40.00 02/24/2016
REVISION ¤40.00 01/19/2016
SITE PLAN 20 ¤20.00 01/19/2016
SURCHARGE FS 533.721 ¤3.80 01/19/2016
SURCHARGE - FS 468.631 ¤3.80 01/19/2016
STORM WATER PERMIT FEES ¤80.00 01/19/2016
ELECTRIC FEE ¤76.80 01/19/2016
MECHANICAL FEE ¤76.80 01/19/2016
PLAN CHECK FEE ¤40.00 01/19/2016
REMODEL/ADDITION/ACCES INSPECT ¤40.00 01/19/2016
ADMIN FEE ¤20.00 01/19/2016
Fees Total Due: ¤0.00 Total Paid: ¤601.20