I want to search for...
Permit #2016010313
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7016-00040-1920 |
| Block: 00040 |
| Subdivision: 2201 - SECTION 16-COUNTRY CLUB COVE |
| Job Phone: 386-206-3150 |
| Location Address: 6 COLLEGE CT |
| Type: BH - BOATHOUSE |
| Issue Date: 01/29/2016 |
| NOC: RECORDED |
| Applicant name: CHARLES M BURGAN III |
| Owner: DANIELS, ROBERT G & DIXIE L |
|
Address 6 COLLEGE COURT PALM COAST, FL 32137 |
| Lot: 1920 |
| Contracted Stated Job Value: ¤10,000.00 |
| Job Description: BOATHOUSE WITH LIFT |
| Type: CN |
Contractor
CHARLES BURGAN, LLC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1132 HARDY ST BUNNELL, FL 32110 |
CGC1512729 (Exp: 08/31/2026) | 386-206-3150 | 386-206-3150 |
Sub Contractors
JOSEPH PAUL BERNHARD
| Status | Location Address | State License Number | Phone |
| CANCEL |
5 RYECORN PLACE PALM COAST, FL 32164 |
EC13004556 (Exp: 08/31/2026) | 386-793-1358 |
JONATHAN P DUCEY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
505 WEST COURT STREET BUNNELL, FL 32110 |
CFC1427093 (Exp: 08/31/2026) | 386-503-6092 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL - BUILDING MISC | 05/12/2016 | FINAL APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| FINAL - BUILDING MISC | 04/22/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/22/2016 2:53:12 PM PERMIT NOT ON SITE, ALSO: BOX-BEAM BOAT LIFT CONSTRUCTION WAS NOT ADDRESSED IN THE REVISION. OBTAIN REVISION SHOWING BOX-BEAM CONSTRUCTION FOR BOAT LIFT OR MAKE CONDITIONS AT SITE MATCH THE PLANS. ALSO YOU DID NOT ADDRESS HOW THE BEAMS WERE TO BE FASTENED TOGETHER (THE HAVE VERY FEW NAILS JOINING THEM) YOU NEED TO GET A REVISION THAT SHOWS FASTENER SCHEDULE FOR NAILING THE BEAMS TOGETHER (I.E. 3- 2.5 INCH NAILS EACH SIDE OF 2X12 BEAM MAX. 18-INCH OC, ETC. ETC. ETC.) | |||
| FINAL - BUILDING MISC | 03/17/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: Inspection Resulted at 3/17/2016 1:09:07 PM PLANS APPEAR TO BE INCOMPLETE (NEED DETAILS FOR HOW 12 INCH HEADER BEAM CORNERS ARE TO BE JOINED,( I.E. BRACKETS/NAILS,HOW MANY NAILS ETC.) PLANS SHOW I-BEAM CONSTRUCTION FOR BOAT LIFT (BOX BEAM WAS INSTSALLED). PLANS SHOW CANTILEAVER OVER OPPOSITE END OF BOAT HOUS. OBTAIN REVISION AND ADD DETAILS. NEED DEPTH GAUGE ADDED TO ELECTRIC AND WATER LINES (INDICATE WHICH ARE FOR WATER LINES AND WHICH ARE FOR ELECTRIC LINES |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/11/2016 | 04/11/2016 |
| ZON | COMPLETE | 04/11/2016 | 04/12/2016 |
| Note: No change to zoning. | |||
| BLD | COMPLETE | 01/26/2016 | 01/26/2016 |
| ZON | COMPLETE | 01/26/2016 | 01/27/2016 |
| BLD | HOLD | 01/15/2016 | 01/15/2016 |
| Note: 1. Provide 30 lb. roofing underlayment per 5th ed. FBC 1507.2.8. 2. Provide Florida product approval for the shingles. J. Hindman 986-3784. | |||
| ZON | HOLD | 01/15/2016 | 01/20/2016 |
| Note: City Legal Dept. preparing Amendment to License Agreement because total area of Agreement will increase with this new structure. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 05/05/2016 |
| REVISION | ¤40.00 | 04/13/2016 |
| REINSPECTION FEE | ¤40.00 | 04/08/2016 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 01/29/2016 |
| ADMIN FEE | ¤20.00 | 01/29/2016 |
| RECORDING FEE REIMBURSE DOC | ¤78.00 | 01/29/2016 |
| PLAN CHECK FEE | ¤40.00 | 01/29/2016 |
| SURCHARGE FS 533.721 | ¤2.00 | 01/29/2016 |
| SURCHARGE - FS 468.631 | ¤2.00 | 01/29/2016 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/29/2016 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤382.00 |