I want to search for...
Permit #2016010721
Permit Details
Status: COED
| Parcel Id: 07-11-31-7022-00050-0160 |
| CONDITIONED SPACE: 2854 sqft |
| GARAGE: 490 sqft |
| OPENED PORCH (WITH ROOF) : 593 sqft |
| OPENED PORCH (WITH ROOF) : 38 sqft |
| Total Square Footage: 3975 sqft |
| Block: 00050 |
| Subdivision: 2217 - SECTION 22-WYNNFIELD |
| Job Phone: 386-236-4133 |
| Location Address: 102 WESTCHESTER LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/08/2016 |
| NOC: RECORDED |
| Applicant name: FRANCIS D MORSE |
| Owner: GOURDINE, PACHELE R & ASHLEY L ALVAREZ |
|
Address 900 CO OP CITY BLVD BRONX, NY 10475 |
|
Address APRT 24E BRONX, NY 10475 |
| Lot: 0160 |
| Contracted Stated Job Value: ¤363,020.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
INTERVEST CONSTRUCTION INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2379 BEVILLE RD DAYTONA BEACH, FL 32119 |
CRC1329858 (Exp: 08/31/2018) | 386-236-4133 | 386-763-7833 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
PAUL S AIELLO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 351926 PALM COAST, FL 32137 |
CAC1815808 (Exp: 08/31/2016) | (386)239-0053 | (386)323-1955 |
GARY WAYNE EVERS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 740106 ORANGE CITY, FL 32763 |
CFC050566 (Exp: 08/31/2026) | 386-775-0909 | 386-775-0918 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 10/27/2016 | FINAL APPROVED | JCOLASANTI |
| ROW FINAL | 10/27/2016 | FINAL APPROVED | GLALIMA |
| Note: $ 460.00 DUE FOE ROAD REPAIR . GARY LA LIMA | |||
| U -UTILITY RESIDENTIAL FINAL | 10/27/2016 | FINAL APPROVED | DSPENCER |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 10/26/2016 | APPROVED - AS NOTED | GLALIMA |
| Note: WORKING ON SOD IN FRONT SWALE | |||
| FINAL SURVEY (OFFICE USE ONLY) | 10/25/2016 | Disapproved - NO FEE | DREWIS |
| Note: South(right) end inverts are too low per the approved swale diagram. -DC. Rewis 986-4736 | |||
| FINAL SURVEY (OFFICE USE ONLY) | 10/25/2016 | APPROVED | DREWIS |
| Note: THIS IS A REINSPECTION | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 09/29/2016 | APPROVED - AS NOTED | GLALIMA |
| Note: IN FIELD ELEVATION CHANGE BY STOMEWATER BECAUSE OF WET SWALE . WILL UP DATE SWALE SHEET | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 09/28/2016 | PARTIALLY APPROVED | GLALIMA |
| Note: READY TO POUR APRON | |||
| ELECTRIC - EARLY POWER | 09/14/2016 | APPROVED - AS NOTED | RMARTIN |
| Note: THIS IS A REINSPECTION spoke to dell fpl released early power 2:30 | |||
| ELECTRIC - EARLY POWER | 09/13/2016 | CANCELLED BY APPLICANT | RMARTIN |
| LATH/BRICK/ WATER BARRIER | 08/08/2016 | APPROVED | LMILLER |
| INSULATION | 08/02/2016 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 08/01/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: THIS IS A REINSPECTIONno paperwork on site | |||
| INSULATION | 07/29/2016 | CANCELLED BY APPLICANT | JCOLASANTI |
| ALL ROUGH | 07/22/2016 | APPROVED - AS NOTED | JCOLASANTI |
| Note: Inspection Resulted at 7/22/2016 11:40:10 AM NEED NAIL PLATES AT BEDROOM, LAUNDRY ROOM WALL....CHECK FIRELOCK KITCHEN VENT. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/30/2016 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/29/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 6/29/2016 12:04:43 PM CONTINUOUS LOAD PATH FOR UPLIFT RESISTANCE FBC.. 802.1.9 AREAS MARKED ON ROOF PLAN..LOOSE SHEETING MARKED ON PLAN....VERIFY STRAPS AT BACK PORCH/HOUSE WALL MARKED ON PLANS (COULD NOT SEE.) | |||
| WALL SHEATHING | 06/27/2016 | APPROVED | JCOLASANTI |
| U - SEWER TIE IN | 06/16/2016 | APPROVED | JNICHOLS |
| Note: all good | |||
| U - SEWER TIE IN | 06/14/2016 | CANCELLED BY APPLICANT | MBACON |
| GRAVITY SEWER TEST | 06/14/2016 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| GRAVITY SEWER TEST | 06/10/2016 | CANCELLED BY APPLICANT | JMONTARULI |
| Note: THIS IS A REINSPECTION William called to cancel this inspection | |||
| U - SEWER TIE IN | 06/10/2016 | CANCELLED BY APPLICANT | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| U - SEWER TIE IN | 05/27/2016 | Disapproved - NO FEE | MBACON |
| Note: Sewer tie in is not visible water in hole. Also sanitary tee is vertical must be horizontal before 45 elbow going down to sewer connection. | |||
| GRAVITY SEWER TEST | 05/27/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: Inspection Resulted at 5/27/2016 9:44:51 AM UNCOVER WORK TO BE INSPECTED..FBC...P2503.2 UNCOVER BELL HUB FOR INSPECTION | |||
| ELECTRIC-TUG | 05/12/2016 | APPROVED - AS NOTED | JCOLASANTI |
| Note: Inspection Resulted at 5/12/2016 3:00:42 PM SPOKE TO DALE AT FPL TO RELEASE POWER FOR TUG. | |||
| TIE BEAM / LINTEL | 05/12/2016 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| TIE BEAM / LINTEL | 05/11/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: Inspection Resulted at 5/11/2016 12:44:46 PM DOWN CELLS R609.1.4, ALL CELLS CONTAINING REINFORCEMENT SHALL BE GROUTED SOLID (CLEAN OUT DEBRIS ALL AREAS, ALSOREMOVE DEBRIS FROM LOWER LENTIL AT PORCH AREA).... CLEARANCE FROM MASONRY R606.13.4 MINIMUM WALL REINFORCING STEEL COVERAGE NOT MET (MAERKED ON STRUCTURAL SHEET) | |||
| TIE BEAM / LINTEL | 05/10/2016 | APPROVED | JCOLASANTI |
| FOUND SURVEY APPROVED (OFFICE) | 05/09/2016 | APPROVED | DREWIS |
| MONOLITHIC SLAB | 04/26/2016 | APPROVED - AS NOTED | JCOLASANTI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/26/2016 3:30:27 PM MAKE SURE STEEL LOCATED FRONT RIGHT GARAGE HAS 3" OF COVERAGE AT TIME OF PLACEMENT OF CONCRETE. | |||
| MONOLITHIC SLAB | 04/25/2016 | Disapproved - NO FEE | JCOLASANTI |
| Note: Inspection Resulted at 4/25/2016 11:15:01 AM FOOTINGS REAR OF HOUSE NEED TO BE 16" DEEP ALONG PERIMETER.....FRONT CORNER OF GARAGE, STEEL NEEDS TO HAVE 3" OF CLEARANCE | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/13/2016 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/08/2016 | CANCELLED BY APPLICANT | JCOLASANTI |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 10/25/2016 | 10/25/2016 |
| Note: Released By: DREWIS | |||
| SW1 | HOLD | 10/24/2016 | 10/25/2016 |
| Note: Held By: DREWIS FINAL S Both invert measurements on the south(right) end of driveway are too low per the approved swale diagram. -DC.Rewis 986-4736 | |||
| ZON | COMPLETE | 08/19/2016 | 08/22/2016 |
| ENGIN1 | COMPLETE | 08/10/2016 | 08/10/2016 |
| Note: A new swale plan has been created to reflect the revised paver circular driveway. | |||
| SW1 | COMPLETE | 08/10/2016 | 08/11/2016 |
| UD1 | COMPLETE | 08/10/2016 | 08/11/2016 |
| Note: All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. | |||
| ZON | HOLD | 08/10/2016 | 08/11/2016 |
| Note: Right-of-Way Utilization Agreement for paver driveway is required. This form must be signed by ALL persons on deed to property, witnessed and notarized. City staff will prepare the Exhibits. | |||
| SW1 | COMPLETE | 05/06/2016 | 05/09/2016 |
| Note: Released By: DREWIS foundation s | |||
| ENGIN1 | COMPLETE | 04/06/2016 | 04/06/2016 |
| SW1 | COMPLETE | 04/06/2016 | 04/07/2016 |
| ZON | COMPLETE | 04/06/2016 | 04/07/2016 |
| SW1 | COMPLETE | 03/02/2016 | 03/07/2016 |
| UD1 | COMPLETE | 03/02/2016 | 03/03/2016 |
| Note: See Notes | |||
| ZON | COMPLETE | 03/02/2016 | 03/03/2016 |
| URB | COMPLETE | 02/15/2016 | 02/15/2016 |
| ELEC | COMPLETE | 02/15/2016 | 02/17/2016 |
| SW1 | HOLD | 02/15/2016 | 02/17/2016 |
| Note: Please provide proposed survey measurements on site plan depicting positive storm water flow. 2nd request. J. Hindman 986-3784 | |||
| ZON | COMPLETE | 02/15/2016 | 02/16/2016 |
| BLD | COMPLETE | 02/01/2016 | 02/01/2016 |
| ELEC | HOLD | 02/01/2016 | 02/01/2016 |
| Note: Please provide a receptacle in hallway from kitchen to bedrooms, NEC 2011 210.52 H. Please provide GFCIs on ends of island countertop, NEC 2011 210.52 C2 -DC. Rewis 986-4736 | |||
| ENGIN1 | COMPLETE | 02/01/2016 | 02/03/2016 |
| MECH | COMPLETE | 02/01/2016 | 02/01/2016 |
| PLUM | COMPLETE | 02/01/2016 | 02/01/2016 |
| SW1 | HOLD | 02/01/2016 | 02/01/2016 |
| Note: Please provide proposed survey measurements on site plan depicting positive storm water flow. -DC. Rewis 986-4736 | |||
| UD1 | COMPLETE | 02/01/2016 | 02/02/2016 |
| Note: See Notes | |||
| ZON | HOLD | 02/01/2016 | 02/02/2016 |
| Note: Proposed pool not allowed to be on SFR permit. Site plan must depict the left side setback from the residence to the closest point of the property line. | |||
| URB | HOLD | 02/01/2016 | 02/01/2016 |
| Note: Need 3 gal shrubbery the full length left side foundation pool and lanai facing the right of way also rear of pool |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤460.00 | 10/28/2016 |
| RECORDING FEE REIMBURSE DOC | ¤52.50 | 09/13/2016 |
| REINSPECTION FEE | ¤40.00 | 09/13/2016 |
| REINSPECTION FEE | ¤40.00 | 09/13/2016 |
| REINSPECTION FEE | ¤40.00 | 09/13/2016 |
| REINSPECTION FEE | ¤40.00 | 09/13/2016 |
| REVISION | ¤40.00 | 09/13/2016 |
| SITE PLAN 20 | ¤20.00 | 03/08/2016 |
| SURCHARGE FS 533.721 | ¤26.33 | 03/08/2016 |
| SURCHARGE - FS 468.631 | ¤26.33 | 03/08/2016 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/08/2016 |
| 3% TRANS IMPACT FEE CREDIT | (¤93.74) | 03/08/2016 |
| NEW RESIDENTIAL INSPECTIONS | ¤728.00 | 03/08/2016 |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | 03/08/2016 |
| MECHANICAL FEE | ¤278.40 | 03/08/2016 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 03/08/2016 |
| PLAN CHECK FEE | ¤145.60 | 03/08/2016 |
| PLUMBING FEE | ¤278.40 | 03/08/2016 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.38) | 03/08/2016 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤212.80 | 03/08/2016 |
| IMPACT FEE PARKS | ¤849.24 | 03/08/2016 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 03/08/2016 |
| ADMIN FEE | ¤20.00 | 03/08/2016 |
| ELECTRIC FEE | ¤278.40 | 03/08/2016 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,255.07 |