I want to search for...
Permit #2016020151
Permit Details
Status: CANCEL
| Parcel Id: 48-11-31-1710-00000-0410 |
| CONDITIONED SPACE: 3100 sqft |
| GARAGE: 1275 sqft |
| OPENED PORCH (WITH ROOF) : 729 sqft |
| OPENED PORCH (WITH ROOF) : 44 sqft |
| Total Square Footage: 5148 sqft |
| Block: 00000 |
| Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II |
| Job Phone: 386-236-4133 |
| Location Address: 3 SCARLET OAK CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/24/2016 |
| NOC: Unknown |
| Applicant name: FRANCIS D MORSE |
| Owner: WILLIAMS, ROBERT & KATHLEEN |
|
Address PO BOX 369 ALLOWAY, NJ 08001 |
| Lot: 0410 |
| Contracted Stated Job Value: ¤428,038.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
INTERVEST CONSTRUCTION INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2379 BEVILLE RD DAYTONA BEACH, FL 32119 |
CRC1329858 (Exp: 08/31/2018) | 386-236-4133 | 386-763-7833 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
PAUL S AIELLO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 351926 PALM COAST, FL 32137 |
CAC1815808 (Exp: 08/31/2016) | (386)239-0053 | (386)323-1955 |
GARY WAYNE EVERS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 740106 ORANGE CITY, FL 32763 |
CFC050566 (Exp: 08/31/2026) | 386-775-0909 | 386-775-0918 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
Inspection History
| Type | Request Date | Result | Inspector |
| LATH/BRICK/ WATER BARRIER | 08/02/2016 | APPROVED | LMILLER |
| GAS ROUGH | 07/27/2016 | Disapproved - NO FEE | LMILLER |
| Note: THIS IS A REINSPECTION FIRE PLACE GAS ROUGH APPROVED, (GRILL, POOL EQUIPMENT AND GAS TANK ROUGH MUST BE CALLED IN PRIOR TO GAS FINAL) | |||
| GAS ROUGH | 07/26/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: STRAPS: SUPPORT OF PIPING EVERY 4 19 REQUIRED FOR SMOOTH WALL PIPING OR EVERY 6 19 FOR STEEL PIPE. FBCG 2424 | |||
| INSULATION | 07/21/2016 | APPROVED | CMINI |
| ALL ROUGH | 07/01/2016 | APPROVED - AS NOTED | LMILLER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/1/2016 3:35:01 PM NEED TO PHASE OUT HOT CONDUCTORS IN BOXES. NEC.210.5(C).. (WILL LOOK FOR THIS AT INSULATION) | |||
| ALL ROUGH | 06/30/2016 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/30/2016 3:13:31 PM MISSING TWO OUTLATS PER PLANNOOK ANDFRONT LIVING ROOM/PROVIDE 19FT HEAD ON SANITARY LINES | |||
| ALL ROUGH | 06/29/2016 | CANCELLED BY APPLICANT | CMINI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/23/2016 | APPROVED | LMILLER |
| WALL SHEATHING | 06/21/2016 | Disapproved - NO FEE | LMILLER |
| Note: Inspection Resulted at 6/21/2016 11:19:08 AM NOT READY | |||
| TIE BEAM / LINTEL | 05/05/2016 | APPROVED | CMINI |
| ELEV CERT-FOUNDATION APPROVAL | 05/04/2016 | APPROVED | DBEVAN |
| ELECTRIC-TUG | 05/02/2016 | APPROVED - AS NOTED | RMARTIN |
| Note: Inspection Resulted at 5/2/2016 2:31:21 PM SPOKE TO DELL FPL RELEASED TUG 2:25 | |||
| FOUND SURVEY APPROVED (OFFICE) | 04/28/2016 | APPROVED | JHINDMAN |
| MONOLITHIC SLAB | 04/12/2016 | APPROVED | CMINI |
| PLUMBING 1ST ROUGH UNDERGROUND | 04/08/2016 | APPROVED | LMILLER |
| GRAVITY SEWER TEST | 04/08/2016 | APPROVED | LMILLER |
| U - SEWER TIE IN | 04/08/2016 | APPROVED | MBACON |
| U -UTILITY RESIDENTIAL FINAL | |||
| BLD - BUILDING FINAL | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | |||
| ROW FINAL | |||
| ELECTRIC - EARLY POWER | |||
| FINAL SURVEY (OFFICE USE ONLY) | |||
| GAS ROUGH | |||
| Note: THIS IS A REINSPECTION | |||
| GAS FINAL | |||
| WALL SHEATHING | |||
| Note: THIS IS A REINSPECTION |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 07/26/2016 | 07/26/2016 |
| PLUM | COMPLETE | 07/25/2016 | 07/25/2016 |
| Note: Revision: added gas riser diagram. Refer to permit 2016030777 for gas tank location. | |||
| PLUM | HOLD | 07/19/2016 | 07/21/2016 |
| Note: Held By: FREODICA Revision : added gas riser diagram. Gas riser diagram shall show the source of gas supply, gas consumption in btu/hr and signature and license number of gas contractor per FBCFG 5th ed. 402/FBC 5th ed. 107.2.1. F.Reodica-386-986-4734. | |||
| PLFM | COMPLETE | 05/04/2016 | 05/04/2016 |
| PLFM | HOLD | 04/28/2016 | 04/29/2016 |
| Note: For Section C2.e, no data is provided. During a previous submittal for a “Construction Drawings”, a proposed elevation was noted as “12.5”. An elevation is required for the “Air Conditioning Pad” as noted in Section D of the previously submitted elevation certificate. Provide the proposed elevation of the AC unit pad per previous submittal. | |||
| SW1 | COMPLETE | 04/26/2016 | 04/28/2016 |
| Note: Released By: JHINDMAN foundation s | |||
| PLFM | COMPLETE | 02/16/2016 | 02/16/2016 |
| BLD | COMPLETE | 02/16/2016 | 02/18/2016 |
| PLFM | HOLD | 02/08/2016 | 02/08/2016 |
| Note: Revise Section B9 to be in tenths. | |||
| BLD | HOLD | 02/05/2016 | 02/05/2016 |
| Note: Provide Florida product approval for garage doors per FBC 5th ed. 107.2.1. F.N.Reodica- 386-986-4734. | |||
| ELEC | COMPLETE | 02/05/2016 | 02/05/2016 |
| ENGIN1 | COMPLETE | 02/05/2016 | 02/05/2016 |
| MECH | COMPLETE | 02/05/2016 | 02/05/2016 |
| PLUM | COMPLETE | 02/05/2016 | 02/05/2016 |
| SW1 | COMPLETE | 02/05/2016 | 02/05/2016 |
| UD1 | COMPLETE | 02/05/2016 | 02/08/2016 |
| Note: See Notes | |||
| ZON | COMPLETE | 02/05/2016 | 02/08/2016 |
| URB | COMPLETE | 02/05/2016 | 02/05/2016 |
| PLUM | HOLD | 07/21/2016 | |
| Note: Gas riser diagram shall show the source of gas supply, gas consumption in btu/hr and signature and license number of gas contractor per FBCFG 5th ed. 402/FBC 5th ed. 107.2.1. F.Reodica-386-986-4734. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| 3% FIRE IMPACT FEE CREDIT | (¤6.38) | 02/24/2016 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤212.80 | 02/24/2016 |
| IMPACT FEE PARKS | ¤849.24 | 02/24/2016 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 02/24/2016 |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | 02/24/2016 |
| MECHANICAL FEE | ¤317.40 | 02/24/2016 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 02/24/2016 |
| PLAN CHECK FEE | ¤171.60 | 02/24/2016 |
| PLUMBING FEE | ¤317.40 | 02/24/2016 |
| ADMIN FEE | ¤20.00 | 02/24/2016 |
| ELECTRIC FEE | ¤317.40 | 02/24/2016 |
| NEW RESIDENTIAL INSPECTIONS | ¤858.00 | 02/24/2016 |
| SITE PLAN 20 | ¤20.00 | 02/24/2016 |
| SURCHARGE FS 533.721 | ¤30.48 | 02/24/2016 |
| SURCHARGE - FS 468.631 | ¤30.48 | 02/24/2016 |
| STORM WATER PERMIT FEES | ¤80.00 | 02/24/2016 |
| 3% TRANS IMPACT FEE CREDIT | (¤93.74) | 02/24/2016 |
| REVISION | ¤40.00 | |
| EXTENSION | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| Fees | Total Due: ¤160.00 | Total Paid: ¤9,823.87 |