I want to search for...

Permit #2016020397

Permit Details

Status: COED

CONDITIONED SPACE: 1900 sqft
GARAGE: 447 sqft
OPENED PORCH (WITH ROOF) : 445 sqft
OPENED PORCH (WITH ROOF) : 68 sqft
Total Square Footage: 2860 sqft
Block: 0RP0C
Subdivision: 2280 - LONGS VIEW CREEK SUBDIVISION
Job Phone: (386)931-1917
Location Address: 66 COLECHESTER LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/25/2016
NOC: RECORDED
Applicant name: BRAD MICHAEL THOMAS
Owner: MCKEON, JAMES R & JANE M

Address

39 FOREST HILL DR

PALM COAST, FL 32137

Lot: 0010
Contracted Stated Job Value: ¤145,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

AUBURN HOMES INC.
Status Location Address State License Number Phone
HOLD

1 HARGROVE GRADE STE 1E

PALM COAST, FL 32137

CGC1506292 (Exp: 08/31/2020) (386)931-1917

Sub Contractors

STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
JOHN ROBERT BLEVINS JR
Status Location Address State License Number Phone Fax
ACTIVE

17 PORWYN LANE

PALM COAST, FL 32164

CAC1816125 (Exp: 08/31/2026) 386-585-8283 386-263-2096
HEATH EDWARD SANFORD
Status Location Address State License Number Phone Fax
ACTIVE

1351 HAZELNUT ST

BUNNELL, FL 32110

CFC1427527 (Exp: 08/31/2026) 386-445-2532 386-445-5575
YORDANIS GONZALEZ
Status Location Address State License Number Phone
ACTIVE

33 RICKENBACKER DRIVE

PALM COAST, FL 32164

CCC1328730 (Exp: 08/31/2026) 386-804-4109

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 09/28/2016 FINAL APPROVED DSPENCER
BLD - BUILDING FINAL 09/27/2016 FINAL APPROVED CMINI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 09/26/2016 CANCELLED BY APPLICANT CMINI
FINAL APRON (AFTER POUR/DRIVEWAY) 09/23/2016 APPROVED RGROSS
Note: APPROVED
ROW FINAL 09/23/2016 APPROVED RGROSS
Note: APPROVED
FINAL SURVEY (OFFICE USE ONLY) 09/22/2016 Disapproved - NO FEE DREWIS
Note: Left culvert invert is too low per approved swale diagram measurement. -DC. Rewis 986-4736
FINAL SURVEY (OFFICE USE ONLY) 09/22/2016 APPROVED DREWIS
Note: THIS IS A REINSPECTION
ELECTRIC - EARLY POWER 09/02/2016 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 3:00
ELECTRIC - EARLY POWER 09/01/2016 CANCELLED BY APPLICANT RMARTIN
PRE-APRON (PRE-POUR/DRIVEWAY) 09/01/2016 APPROVED - AS NOTED RGROSS
Note: BENCHMARK ON CATCH BASIN ISSUE CLEARED UP BY CHUCK AND JEFF ON SITE. WILL NEED REVISED SWALE PLAN SHOWING FLOW IN THE RIGHT DIRECTION. CULVERT ELEVATION ALSO CHECKED BY CHUCK AND JEFF. READY TO POUR. HEAVY RAINS IN THE FORCAST. RECHECK ELEVATIONS BEFORE POURING. CONTRACTOR NOTIFIED VIA PHONE THAT PORT O LET NEEDS REMOVED FROM CENTER OF SWALE AND CATCH BASIN NEEDS PROTECTED FROM LOOSE MATERIAL WASHOUT.
LATH/BRICK/ WATER BARRIER 07/07/2016 APPROVED CMINI
INSULATION 07/01/2016 APPROVED LMILLER
Note: THIS IS A REINSPECTION
INSULATION 06/30/2016 Disapproved -FEE REQUIRED LMILLER
Note: Inspection Resulted at 6/30/2016 11:27:08 AM MISSING INSULATION IN KNEE WALL OVER GARAGE / RESIDENCE SEPARATION WALL. PROVIDE FIRE CAULKING AT FEERED HEADER OVER SLIDER
U - SEWER TIE IN 06/30/2016 APPROVED JNICHOLS
GRAVITY SEWER TEST 06/30/2016 APPROVED LMILLER
ALL ROUGH 06/16/2016 APPROVED CMINI
Note: THIS IS A REINSPECTION
ALL ROUGH 06/15/2016 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 6/15/2016 11:55:01 AM NEED NAIL PLATES ON ELECTRIC BACK BD.RM AND MASTER BATH, CHECK ALL NEC 300.4. MISSING RECEPTICLE NEXT TO SLIDER PER PLAN, TO ACHIEVE 6`` WALL SPACING. STAP ROMEX IN MASTER BD.RM NEC 334.30 FIREBLOCKING NEEDED WHERE WALLS WERE FURRED OUT FBC 302. .MISSING WINDOW ANCHORING SCHEDULE.GAS PIPE NEEDS TO BE SUPPORTED EVERY 6`` VERTICAL FBC.G. 2424.1 NEED TO OVERLAP TOP PLATE OF MITERED WINDOW
ELECTRIC-TUG 06/14/2016 APPROVED - AS NOTED RMARTIN
Note: Inspection Resulted at 6/14/2016 2:22:13 PM SPOKE TO SUSAN FPL RELEASED TUG 2:10
ALL ROUGH 06/09/2016 CANCELLED BY APPLICANT LMILLER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/27/2016 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/26/2016 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 5/26/2016 10:52:06 AM MISSING NUMEROUS STRAPS ON TRUSSESCIRCLED ON PLAN. CHECK ALL. MISSING NAILS ON X-BRACING PER PLAN. MISSING ANCHORING ON BEARING WALL AT REAR BATH.
TIE BEAM / LINTEL 05/03/2016 APPROVED LMILLER
ELEV CERT-FOUNDATION APPROVAL 05/02/2016 APPROVED DBEVAN
Note: Approved by Denise Bevan
FOUND SURVEY APPROVED (OFFICE) 04/18/2016 APPROVED DREWIS
MONOLITHIC SLAB 04/05/2016 APPROVED LMILLER
PLUMBING 1ST ROUGH UNDERGROUND 04/04/2016 APPROVED LMILLER
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 04/01/2016 CANCELLED BY APPLICANT LMILLER
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 03/23/2016 Disapproved -FEE REQUIRED LMILLER
Note: Inspection Resulted at 3/23/2016 12:01:57 PM 10’ HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.4, AND OR FBC CHAPTER 25 SECTION P2503.5.1 BUILDING SEWER TESTING. TESTING WITH NOT LESS THAN 10-FOOT (3048MM) OF HEAD WATER AND BE ABLE TO MAINTAIN SUCH PRESSURE FOR 15 MINUTES MUST USE WATER FOR TESTING PLASTIC PIPE...... PRESSURE TEST FOR SUPPLY LINES P2503.7 WATER SUPPLY-SYSTEM TESTING. MUST USE WATER FOR PLASTIC PIPE NOT LESS THAN THE WORKING PRESSURE OF THE SYSTEM OR 50 PSI… FOR NOT LESS THAN 15 MINUTES

Review History

Department Status Date In Date Out
ELEC COMPLETE 09/22/2016 09/26/2016
PLFM COMPLETE 09/22/2016 09/23/2016
SW1 COMPLETE 09/22/2016 09/26/2016
SW1 COMPLETE 09/22/2016 09/22/2016
Note: Released By: DREWIS FINAL S
SW1 HOLD 09/21/2016 09/22/2016
Note: Held By: DREWIS Left culvert invert is too low per approved swale diagram measurement. -DC. Rewis 986-4736
ELEC COMPLETE 08/03/2016 08/04/2016
PLFM COMPLETE 04/29/2016 04/29/2016
PLFM HOLD 04/28/2016 04/28/2016
Note: Section C2.e The provided elevation certificate for “Building Under Construction” notes a N/A. During a previous submittal for “Construction Drawings”, a proposed elevation was noted as “10.44”. An elevation is required for the “Air Conditioning Pad” as noted in Section D of the previously submitted elevation certificate. In Building Street Address section A2, indicate the unit number. There will be additional lots improved with the same address "66 Colechester Lane"; a unit # is critical to ensure that the EC is not confused with contigous properties.
SW1 COMPLETE 04/15/2016 04/18/2016
Note: Released By: DREWIS foundation s
URB COMPLETE 03/03/2016 03/03/2016
ZON COMPLETE 03/03/2016 03/04/2016
URB COMPLETE 02/23/2016 02/24/2016
ZON COMPLETE 02/19/2016 02/22/2016
PLFM COMPLETE 02/19/2016 02/19/2016
URB HOLD 02/19/2016 02/19/2016
Note: Need to install 3 gallon shrubbery left side of garage.
PLFM HOLD 02/12/2016 02/12/2016
Note: 1. The property is within the AE special flood hazard area. Provide an elevation certificate.
BLD COMPLETE 02/12/2016 02/12/2016
ELEC COMPLETE 02/12/2016 02/12/2016
Note: Add GFCIs to kitchen counter top per NEC 2011 210.52 C. -DC. Rewis 986-4736
ENGIN1 COMPLETE 02/12/2016 02/15/2016
MECH COMPLETE 02/12/2016 02/12/2016
PLUM COMPLETE 02/12/2016 02/12/2016
SW1 COMPLETE 02/12/2016 02/12/2016
UD1 COMPLETE 02/12/2016 02/16/2016
Note: See Notes
ZON HOLD 02/12/2016 02/12/2016
Note: Foundation plantings are required to wrap the corners of the house.
URB HOLD 02/12/2016 02/15/2016
Note: Need to install 3 gal shrubbery left side of garage and wrap all corners of house and porch with 3 gal shrubs.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 09/28/2016
REINSPECTION FEE ¤40.00 09/28/2016
REINSPECTION FEE ¤40.00 09/28/2016
REINSPECTION FEE ¤40.00 09/28/2016
REVISION ¤40.00 09/28/2016
REVISION ¤40.00 09/28/2016
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 02/25/2016
SURCHARGE FS 533.721 ¤19.04 02/25/2016
SURCHARGE - FS 468.631 ¤19.04 02/25/2016
TRANSPORTATION IMPACT FEE3/RES ¤3,124.67 02/25/2016
3% TRANS IMPACT FEE CREDIT (¤93.74) 02/25/2016
3% FIRE IMPACT FEE CREDIT (¤6.38) 02/25/2016
FIRE RESIDENTIAL IMPACT FEE ¤212.80 02/25/2016
PARKS IMPACT FEE ¤849.24 02/25/2016
3% PARKS IMPACT FEE CREDIT (¤25.48) 02/25/2016
Fees Total Due: ¤0.00 Total Paid: ¤7,939.19