I want to search for...
Permit #2016020552
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7007-00410-0080 |
| CONDITIONED SPACE: 2275 sqft |
| GARAGE: 560 sqft |
| GARAGE: 169 sqft |
| OPENED PORCH (WITH ROOF) : 388 sqft |
| OPENED PORCH (WITH ROOF) : 128 sqft |
| Total Square Footage: 3520 sqft |
| Block: 00410 |
| Subdivision: 2185 - SECTION 7-FLORIDA PARK |
| Job Phone: (386)445-9055 |
| Location Address: 23 FURNESS PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/21/2016 |
| NOC: Unknown |
| Applicant name: LUIS JORGE MEDEIROS |
| Owner: DESOUSA, FERNANDO A & LUISA B |
|
Address 191 PRITCHARD DRIVE PALM COAST, FL 32164 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤235,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
NEW COASTAL HOMES INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
399 SW PALM COAST PKWY PALM COAST, FL 32137 |
STE5 PALM COAST, FL 32137 |
CRC1327024 (Exp: 08/31/2018) | (386)445-9055 | (386)445-9056 |
Sub Contractors
CHARLES K DAVIS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3000 E MOODY BLVD BLDG 2 BUNNELL , FL 32110 |
EC13004270 (Exp: 08/31/2026) | 386-931-6614 |
PAUL S AIELLO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 351926 PALM COAST, FL 32137 |
CAC1815808 (Exp: 08/31/2016) | (386)239-0053 | (386)323-1955 |
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
Inspection History
| Type | Request Date | Result | Inspector |
| TIE BEAM / LINTEL | 07/07/2016 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| TIE BEAM / LINTEL | 07/06/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: Inspection Resulted at 7/6/2016 10:57:37 AM AT FRONT ENTRY 2 DOWNRODS ARE CONNECTED TO ONE FOUNDATION ROD, DOWN CELLS R609.1.4, ALL CELLS CONTAINING REINFORCEMENT SHALL BE GROUTED SOLIDN (CLEAN OUT DEBRIS). OVERBEND DOWEL BAR FBC R606.13.3 (DRILL AND EPOXY). CLEARANCE FROM MASONRY R606.13.4 MINIMUM WALL REINFORCING STEEL COVERAGE NOT MET. (ALL MARKED WITH GREEN PAIN) WASHER WITH TUB ADJACENT REQUIRES 2 INCH VTR (NOT COMPLETED THROUGH WALL), TYPICAL BOND BEAM REQUIRES TWO COURSES AS WELL AS STEP DOWN BOND BEAM (MISSING AT LEFT SIDE OF FRONT DOOR NEAR BAY AREA. SPLICE LENGTH MINIMUM 25 INCHES R606.13.2 SPLICES MUST OVERLAP A MINIMUM OF 25 INCHES FOR NUMBER 5 BARS (CHECK ALL) | |||
| FOUND SURVEY APPROVED (OFFICE) | 06/28/2016 | APPROVED | FREODICA |
| MONOLITHIC SLAB | 05/27/2016 | APPROVED | CMINI |
| PLUMBING 1ST ROUGH UNDERGROUND | 05/25/2016 | APPROVED | CMINI |
| GRAVITY SEWER TEST | |||
| ELECTRIC - EARLY POWER | |||
| FINAL SURVEY (OFFICE USE ONLY) | |||
| LATH/BRICK/ WATER BARRIER | |||
| ALL ROUGH | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | |||
| INSULATION | |||
| BLD - BUILDING FINAL | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | |||
| ROW FINAL | |||
| U - SEWER TIE IN | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 02/22/2017 | 02/24/2017 |
| SW1 | COMPLETE | 06/27/2016 | 06/28/2016 |
| Note: Released By: FREODICA foundation s | |||
| ZON | COMPLETE | 04/05/2016 | 04/07/2016 |
| ZON | HOLD | 03/21/2016 | 03/22/2016 |
| Note: REPEAT COMMENT: 3. Right of Way Utilization Agreement for paver driveway is required. Note that the form must be signed by ALL persons on property deed, witnessed and notarized. | |||
| ELEC | COMPLETE | 03/21/2016 | 03/21/2016 |
| SW1 | COMPLETE | 03/21/2016 | 03/21/2016 |
| UD1 | COMPLETE | 03/21/2016 | 03/23/2016 |
| URB | COMPLETE | 03/21/2016 | 03/22/2016 |
| PLUM | COMPLETE | 03/21/2016 | 03/21/2016 |
| BLD | COMPLETE | 03/21/2016 | 03/21/2016 |
| PLLA | COMPLETE | 03/21/2016 | 03/21/2016 |
| Note: Released By: WBUTLER | |||
| PLLA | HOLD | 02/19/2016 | 02/19/2016 |
| Note: Held By: WBUTLER Bill Butler has folder for review - done manually. 1) This home will require stemwall construction for the foundation due to the extreme change in grade at the rear of the property and the proximity to the floodway. If access to the rear porch is needed, an elevated deck or steps can be provided with the re-submittal or in the future by separate permit. 2) Need to indicate on the survey that there will be no change of grade in the rear and to save the existing trees located in that area. 3) Do not plant the magnolia tree in the location shown in the right rear corner of the lot as this is in the floodway. | |||
| BLD | HOLD | 02/17/2016 | 02/18/2016 |
| Note: Provide Florida product approval for garage door and roofing material to be used per FBC 5th ed. 107.2.1. Provide a stemwall at the rear per Bill Butlers note due to Floodway.F.N. Reodica - 386-986-4734. | |||
| ELEC | HOLD | 02/17/2016 | 02/22/2016 |
| Note: 1. Provide electrical load calculations 2011 NEC art 220. J. Hindman 986-3784. | |||
| ENGIN1 | COMPLETE | 02/17/2016 | 02/29/2016 |
| MECH | COMPLETE | 02/17/2016 | 02/18/2016 |
| PLUM | HOLD | 02/17/2016 | 02/18/2016 |
| Note: 1.Sanitary riser diagram does not match with floor plan and also shall have signature and license number of plumbing contractor per FBC 5th ed. 107.2.1. 2. The vent size for master bathroom group fixtures shall comply with FBCR 5th ed. Table P3108.3. F.N.Reodica - 386-986-4734. | |||
| SW1 | HOLD | 02/17/2016 | 02/22/2016 |
| Note: 1. Provide a stemwall for the rear of house due to Floodway. See Bill Butlers comments. J. hindman 986-3784. | |||
| UD1 | HOLD | 02/17/2016 | 02/18/2016 |
| Note: Gravity sewer location is not marked on utility site plan. Please mark sewer and resubmit. | |||
| ZON | HOLD | 02/17/2016 | 02/19/2016 |
| Note: 1. Lots 7 & 8 are legally bound together. Provide a site plan depicting the entire property. 2. Landscape plan required depicting entire property (refer to #1 above). 3. Right of Way Utilization Agreement for paver driveway is required. Note that the form must be signed by ALL persons on property deed, witnessed and notarized. | |||
| PLFM | COMPLETE | 02/17/2016 | 02/19/2016 |
| URB | HOLD | 02/17/2016 | 02/18/2016 |
| Note: Need to submit a landscape plan |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ELECTRIC FEE | ¤242.40 | 04/21/2016 |
| ADMIN FEE | ¤20.00 | 04/21/2016 |
| RECORDING FEE REIMBURSE DOC | ¤52.50 | 04/21/2016 |
| MECHANICAL FEE | ¤242.40 | 04/21/2016 |
| PLAN CHECK FEE | ¤121.60 | 04/21/2016 |
| PLUMBING FEE | ¤242.40 | 04/21/2016 |
| NEW RESIDENTIAL INSPECTIONS | ¤608.00 | 04/21/2016 |
| SITE PLAN 20 | ¤20.00 | 04/21/2016 |
| SURCHARGE FS 533.721 | ¤22.79 | 04/21/2016 |
| SURCHARGE - FS 468.631 | ¤22.79 | 04/21/2016 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/21/2016 |
| REINSPECTION FEE | ¤40.00 | |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | |
| CONTRACTOR CHANGE | ¤40.00 | |
| EXTENSION | ¤40.00 | |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤212.80 | |
| IMPACT FEE PARKS | ¤849.24 | |
| IMPACT FEE SCHOOL | ¤3,600.00 | |
| Fees | Total Due: ¤7,906.71 | Total Paid: ¤1,674.88 |