I want to search for...
Permit #2016020733
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7026-00700-0160 |
| Block: 00700 |
| Subdivision: 2153 - SECTION 26-PINE GROVE |
| Job Phone: 386-449-9413 |
| Location Address: 40 PITTMAN DR |
| Type: WA - WALL - MASONRY |
| Issue Date: 03/24/2016 |
| NOC: RECORDED |
| Applicant name: STEVE HARKINS |
| Owner: SCAVETTA, JOSEPH V & PATRICIA J |
|
Address 47-04 21ST AVENUE ASTORIA, NY 11105 |
| Lot: 0160 |
| Contracted Stated Job Value: ¤8,000.00 |
| Job Description: CONCRETE FOOTING W/BLOCK RETAINING WALL |
| Type: CN |
Contractor
HARKINS CUSTOM CONSTRUCTION INC.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
665 STREET TRAIL BUNNELL, FL 32110 |
CBC1253997 (Exp: 08/31/2026) | 386-449-9413 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL - BUILDING MISC | 07/15/2016 | FINAL APPROVED | LMILLER |
| RETAINING WALL | 04/11/2016 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| RETAINING WALL | 04/08/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: Inspection Resulted at 4/8/2016 1:22:59 PM NOT BUILT PER APPROVED PLANS. NEED PVC WEEP HOLES AT 10FT INTERVALS, NEED VIRTICAL RODS AT 32IN. OC. (DRILL AND EPOXY). NEED TO TIE VERTICLE RODS INTO HORIZONTAL STEEL IN BOND BEAM. SLEEVES… PIPES PASSING THROUGH FOUNDATION WALLS P2603.4 SLEEVES… (SLEEVES MUST BE 2 PIPE SIZES GREATER THAN THE PIPE PASSING THROUGH THE WALL | |||
| RETAINING WALL FOUNDATION | 03/29/2016 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION per contractor | |||
| RETAINING WALL FOUNDATION | 03/28/2016 | CANCELLED BY APPLICANT | JCOLASANTI |
Review History
| Department | Status | Date In | Date Out |
| URB | COMPLETE | 03/01/2016 | 03/02/2016 |
| ZON | COMPLETE | 03/01/2016 | 03/02/2016 |
| BLD | COMPLETE | 02/24/2016 | 02/29/2016 |
| SW1 | COMPLETE | 02/24/2016 | 02/29/2016 |
| URB | HOLD | 02/24/2016 | 02/24/2016 |
| Note: Need to submit a landscape plan showing 3 gallon shrubbery type placed 3' on center for any wall greater then 36" tall. | |||
| ZON | HOLD | 02/24/2016 | 02/25/2016 |
| Note: Per LDC 4.02.01.3.d.(2) - Split-faced block walls must be finished so that the block seams are not visible. Provide height of proposed retaining wall to demonstrate that it will not be higher than 6' from finished grade. Any retaining wall three (3) feet tall or higher shall have shrubbery installed along its length. Shrub species shall be selected such that the mature height shall be proportionate to the height of the wall with fifty (50) percent of the wall height being covered. (LDC, Subsection 11.03.01.L) |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 07/14/2016 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 03/24/2016 |
| SITE PLAN 20 | ¤20.00 | 03/24/2016 |
| SURCHARGE FS 533.721 | ¤2.00 | 03/24/2016 |
| SURCHARGE - FS 468.631 | ¤2.00 | 03/24/2016 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/24/2016 |
| ADMIN FEE | ¤20.00 | 03/24/2016 |
| PLAN CHECK FEE | ¤40.00 | 03/24/2016 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤244.00 |