I want to search for...
Permit #2016020853
Permit Details
Status: COED
| Parcel Id: 07-11-31-7035-00420-0110 |
| CONDITIONED SPACE: 2472 sqft |
| GARAGE: 627 sqft |
| OPENED PORCH (WITH ROOF) : 120 sqft |
| OPENED PORCH (WITH ROOF) : 191 sqft |
| Total Square Footage: 3410 sqft |
| Block: 00420 |
| Subdivision: 2172 - SECTION 35-BELLE TERRE |
| Job Phone: 904-268-7730 |
| Location Address: 5 BUTTERMILL DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/08/2016 |
| NOC: RECORDED |
| Applicant name: KENNETH WAYNE CAMPBELL JR |
| Owner: MARONDA HOMES, INC |
|
Address 9700 PHILLIPS HWY STE 102 JACKSONVILLE, FL 32256 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤116,072.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MARONDA HOMES INC. OF FLORIDA
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
6800 SOUTHPOINT PKWAY SUITE 300 JACKSONVILLE, FL 32216 |
CBC058803 (Exp: 08/31/2018) | 904-268-7730 | 904-268-7740 |
Sub Contractors
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
DEBORAH MAXINE JACKSON
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
9474 OLD PLANK RD JACKSONVILLE , FL 32220 |
CCC1328530 (Exp: 08/31/2016) | 904-435-7663 | 904-404-8406 |
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 10/28/2016 | FINAL APPROVED | JNICHOLS |
| BLD - BUILDING FINAL | 10/27/2016 | FINAL APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 10/26/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: LOCKING CAPS, 30 AMP BREAKER IN PANEL, CITY STAMPED FINAL SURVEY, SWITCH FOR GARBAGE DISPOSAL | |||
| ROW FINAL | 10/21/2016 | APPROVED | RGROSS |
| Note: APPROVED | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | 10/19/2016 | APPROVED | RGROSS |
| Note: APPROVED | |||
| FINAL SURVEY (OFFICE USE ONLY) | 10/18/2016 | APPROVED | JHINDMAN |
| ELECTRIC - EARLY POWER | 10/14/2016 | APPROVED - AS NOTED | RMARTIN |
| Note: WILL CONTINUE TO CALL FPL TO RELEASE POWER, PHONE LINE IS STILL DOWN DUE TO STORM | |||
| TUB SET | 09/30/2016 | APPROVED | LMILLER |
| PRE-APRON (PRE-POUR/DRIVEWAY) | 09/21/2016 | APPROVED | RGROSS |
| Note: READY TO POUR | |||
| LATH/BRICK/ WATER BARRIER | 09/07/2016 | APPROVED | JCOLASANTI |
| U - SEWER TIE IN | 08/30/2016 | APPROVED | JNICHOLS |
| INSULATION | 08/23/2016 | CANCELLED BY APPLICANT | AIRS WEB |
| INSULATION | 08/18/2016 | APPROVED | JCOLASANTI |
| ALL ROUGH | 08/12/2016 | APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 08/11/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: THIS IS A REINSPECTION NAIL PLATES ON ELECTRIC FBC E3802.1 WIRING, AND LOW VOLTAGE, AND AC (MARKED WITH RED MARKER). STRAPPING OF SER NEC.334 NEEDS TO BE STRAPPED PER NEC 334 ADD TUB SET INSPECTON WHEN GARDEN TUB IS SET | |||
| ALL ROUGH | 08/08/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: TO MANY DEFICIENT ITEMS, INSPECTION STOPPED, INCOMPLETE LIST, PARTIAL LIST ASS FOLLOWS; OUTLETS WITHIN 6 feet OF DOORS 26 NEC 210.52 smoke detectors need to be 3' from ducts or vents and ceiling fan blade tips: NFPA 72 29.8.3.4(5) from the 2010. NAIL PLATES ON ELECTRIC FBC E3802.1 (check all) missing exhaust fans per plans (all) | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/08/2016 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/07/2016 | Disapproved - NO FEE | JCOLASANTI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/7/2016 11:59:32 AM NEED TO INSTALL STRAP ON TRUSS T01 PLAN CALLS FOR TWO STRAPS, CLIPS ON GABLE OK AS INSTALLED EXTERIOR. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/06/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/6/2016 12:09:27 PM WORK NOT COMPLETED, COMPLETE WORK PER PLAN OR OBTAIN REVISION TO EXCLUDE WORK. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/05/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 7/5/2016 3:14:47 PM MISSING STRAP TRUSS T01 GARAGE EXT. WALL....NEED MTS12 AT OUTLOOKERS DETAIL GE21 | |||
| TIE BEAM / LINTEL | 06/22/2016 | APPROVED | JCOLASANTI |
| MONOLITHIC SLAB | 06/14/2016 | APPROVED | JCOLASANTI |
| FOUND SURVEY APPROVED (OFFICE) | 06/07/2016 | APPROVED | DREWIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 06/03/2016 | APPROVED | JCOLASANTI |
| GRAVITY SEWER TEST | 06/03/2016 | APPROVED | JCOLASANTI |
| STEM WALL FOUNDATION | 05/25/2016 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| STEM WALL FOUNDATION | 05/24/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/24/2016 12:00:39 PM CLEARANCE ON REBAR FROM EARTH 3†FBC 403 (VARIOUS AREAS AROUND FOOTING HAS DIRT UNDER STEEL FROM WASHOUT THAT NEEDS TO BE REMOVED. ) | |||
| STEM WALL FOUNDATION | 05/20/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 5/20/2016 10:47:09 AM NEED TO ACHIEVE 95% COMPACTION FOR PAD AND FOOTINGS. |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 10/17/2016 | 10/18/2016 |
| Note: Released By: JHINDMAN FINAL S | |||
| SW1 | COMPLETE | 06/06/2016 | 06/07/2016 |
| Note: Released By: DREWIS foundation s | |||
| PLUM | COMPLETE | 03/29/2016 | 03/29/2016 |
| PLUM | HOLD | 03/21/2016 | 03/21/2016 |
| Note: Repeat comment: Sanitary riser diagram does not match with floor plan. Coordinate and submit correction per FBC 5th ed. 107.2.1. F.N.Reodica -386-986-4734. Please note the tub is still missing at the master bathroom on sanitary riser diagram. | |||
| ZON | COMPLETE | 03/21/2016 | 03/21/2016 |
| ELEC | COMPLETE | 03/21/2016 | 03/21/2016 |
| UD1 | COMPLETE | 03/21/2016 | 03/23/2016 |
| BLD | COMPLETE | 02/29/2016 | 02/29/2016 |
| ELEC | HOLD | 02/29/2016 | 03/01/2016 |
| Note: Please provide per NEC 2011: Receptacles, bedrooms 2 & 3, and den(flex room wall) Article 210.52. Receptacles needed in foyer, 210.52i Disconnect for AHU, Article 440.14. -DC. Rewis 986-4736 | |||
| ENGIN1 | COMPLETE | 02/29/2016 | 03/07/2016 |
| MECH | COMPLETE | 02/29/2016 | 02/29/2016 |
| PLUM | HOLD | 02/29/2016 | 02/29/2016 |
| Note: Sanitary riser diagram does not match with floor plan. Coordinate and submit correction per FBC 5th ed. 107.2.1. F.N.Reodica -386-986-4734. | |||
| SW1 | COMPLETE | 02/29/2016 | 03/01/2016 |
| UD1 | HOLD | 02/29/2016 | 03/03/2016 |
| Note: PEP Panel is not shown in the electrical plan. Submit a new electrical plan showing PEP Panel on the building on the same side of the building as indicated in the Utility marked site plan. Also no Pep location on utility marked site plan. | |||
| ZON | HOLD | 02/29/2016 | 03/01/2016 |
| Note: Stucco banding must wrap BOTH front corners of home for a minimum of 2'. | |||
| URB | COMPLETE | 02/29/2016 | 02/29/2016 |
| Note: FYI shade tree front must have 15ft set-back from the service power line. | |||
| ELEC | HOLD | 03/01/2016 | |
| Note: Provide signed and sealed drawings. Please provide per NEC 2011: Receptacles, bedrooms 2 & 3, and den(flex room wall) Article 210.52. Receptacles needed in foyer, 210.52i Disconnect for AHU, Article 440.14. -DC. Rewis 986-4736 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 10/28/2016 |
| REINSPECTION FEE | ¤40.00 | 10/28/2016 |
| REINSPECTION FEE | ¤40.00 | 10/28/2016 |
| REINSPECTION FEE | ¤40.00 | 10/28/2016 |
| REINSPECTION FEE | ¤40.00 | 10/28/2016 |
| REINSPECTION FEE | ¤40.00 | 10/28/2016 |
| REINSPECTION FEE | ¤40.00 | 10/28/2016 |
| NEW RESIDENTIAL INSPECTIONS | ¤626.00 | 04/08/2016 |
| SITE PLAN 20 | ¤20.00 | 04/08/2016 |
| SURCHARGE FS 533.721 | ¤23.06 | 04/08/2016 |
| SURCHARGE - FS 468.631 | ¤23.06 | 04/08/2016 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/08/2016 |
| 3% TRANS IMPACT FEE CREDIT | (¤93.74) | 04/08/2016 |
| ADMIN FEE | ¤20.00 | 04/08/2016 |
| ELECTRIC FEE | ¤247.80 | 04/08/2016 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.38) | 04/08/2016 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤212.80 | 04/08/2016 |
| IMPACT FEE PARKS | ¤849.24 | 04/08/2016 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 04/08/2016 |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | 04/08/2016 |
| MECHANICAL FEE | ¤247.80 | 04/08/2016 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 04/08/2016 |
| PLAN CHECK FEE | ¤125.20 | 04/08/2016 |
| PLUMBING FEE | ¤247.80 | 04/08/2016 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,601.83 |