I want to search for...

Permit #2016030369

Permit Details

Status: COED

Parcel Id: 07-11-31-7027-00450-0230
CONDITIONED SPACE: 2272 sqft
GARAGE: 511 sqft
OPENED PORCH (WITH ROOF) : 449 sqft
OPENED PORCH (WITH ROOF) : 90 sqft
Total Square Footage: 3322 sqft
Block: 00450
Subdivision: 2128 - SECTION 27-WYNNFIELD
Job Phone: (386)405-0323
Location Address: 18 WOOD CENTER LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/29/2016
NOC: RECORDED
Applicant name: SERGE ROMANYSZYN
Owner: SERGE & LINDA ROMANYSZYN

Address

20 ZINNIA LANE

PALM COAST, FL 32164

Lot: 0230
Contracted Stated Job Value: ¤200,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

ROMAN BUILDING CONTRACTORS LLC.
Status Location Address State License Number Phone
CANCEL

PO BOX 1265

PALM COAST, FL 32137

CBC1253753 (Exp: 08/31/2022) (386)405-0323

Sub Contractors

JOSEPH JOHN VERRECHIO
Status Location Address Mailing Address State License Number Phone
CANCEL

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3D

PALM COAST, FL 32137

EC13004254 (Exp: 08/31/2016) 386-793-1811
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
SERGE ROMANYSZYN
Status Location Address State License Number Phone
CANCEL

PO BOX 1265

PALM COAST, FL 32137

CBC1253753 (Exp: 08/31/2022) (386)405-0323
JOHN ROBERT BLEVINS JR
Status Location Address State License Number Phone Fax
ACTIVE

17 PORWYN LANE

PALM COAST, FL 32164

CAC1816125 (Exp: 08/31/2026) 386-585-8283 386-263-2096

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 12/27/2016 APPROVED DSPENCER
BLD - BUILDING FINAL 12/22/2016 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 12/21/2016 CANCELLED BY APPLICANT JCOLASANTI
FINAL APRON (AFTER POUR/DRIVEWAY) 12/16/2016 APPROVED RGROSS
Note: THIS IS A REINSPECTION. CORRECTIONS MADE. APPROVED
ROW FINAL 12/16/2016 APPROVED RGROSS
Note: THIS IS A REINSPECTION
ROW FINAL 12/15/2016 Disapproved - NO FEE RGROSS
Note: THIS IS A REINSPECTION. MISSING DOCUMENTATION. NO FINAL SURVEY ON SITE. SOD BARE EARTH AREAS IN THE ROW AND SEED AND STRAW BARE EARTH AREAS BEYOND THE ROW AND AROUND PROPERTY PERIMETER.
FINAL APRON (AFTER POUR/DRIVEWAY) 12/15/2016 Disapproved -FEE REQUIRED RGROSS
Note: THIS IS A REINSPECTION. MISSING DOCUMENTATION. NO FINAL SURVEY ON SITE. COULD NOT VERIFY FINAL DONCUENTED CULVERT ELEVATIONS.
FINAL APRON (AFTER POUR/DRIVEWAY) 12/08/2016 Disapproved - NO FEE RGROSS
Note: MISSING DOCUMENTATION. NEED TO HAVE FINAL SURVEY AND SWALE PLAN ON SITE.
ROW FINAL 12/08/2016 Disapproved -FEE REQUIRED RGROSS
Note: ROAD EDGE AT THE END OF DRIVEWAY NEEDS TO BE REMOVED AND HOT PATCHED. FINAL SURVEY AND SWALE PLAN MUST BE ON SITE.
FINAL SURVEY (OFFICE USE ONLY) 12/07/2016 APPROVED FREODICA
Note: THIS IS A REINSPECTION
FINAL SURVEY (OFFICE USE ONLY) 12/05/2016 Disapproved - NO FEE FREODICA
Note: Fnal survey does not show positive drainage from the rear to the front at the left side of the property.
PRE-APRON (PRE-POUR/DRIVEWAY) 11/01/2016 APPROVED - AS NOTED CTROHA
Note: MEETS ALL REQUIREMENTS AT TIME OF INSPECTION READY TO POUR It is the BUILDER'S RESPONSIBILITY to recheck elevations and pipe size and to insure that an obstruction does not exist upstream and or downstream PRIOR to placement of concrete. LS OF DRIVEWAY SET AT 7'8" DUE TO CURVE OF ROAD ADJUSTMENT MADE IN THE FIELD BY CONRAD TROHA PIPE TO THE RIGHT SIDE OF THE DRIVEWAY IS OVER THE PROPERTY LINE
ELECTRIC - EARLY POWER 09/30/2016 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 3:15
U - SEWER TIE IN 09/27/2016 APPROVED DSPENCER
Note: THIS IS A REINSPECTION
GRAVITY SEWER TEST 08/18/2016 APPROVED JCOLASANTI
LATH/BRICK/ WATER BARRIER 08/01/2016 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
INSULATION 07/21/2016 APPROVED JCOLASANTI
U - SEWER TIE IN 07/12/2016 CANCELLED BY APPLICANT JNICHOLS
Note: Builder will call in when it is completed. He had a problem with the plumber.
ALL ROUGH 07/12/2016 APPROVED - AS NOTED JCOLASANTI
Note: Inspection Resulted at 7/12/2016 3:51:43 PM CHECK NAIL PLATES AT INSULATION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/21/2016 APPROVED - AS NOTED JCOLASANTI
Note: THIS IS A REINSPECTION PER CONTRACTOR Inspection Resulted at 6/21/2016 10:55:55 AM TRUSS TO1 NEEDS TWO PIECES OF ENGINEERING CHECK NEXT INSPECTION
ROOF VALLEY & METAL 06/21/2016 APPROVED JCOLASANTI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/17/2016 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION BRACES/TIES Inspection Resulted at 6/17/2016 1:56:02 PM ENGINEERING NOT COMPLETE, STRAP AT PORCH NEEDS TO BE TAPCONED. ALL OTHER OK
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/14/2016 PARTIALLY APPROVED JCOLASANTI
Note: Inspection Resulted at 6/14/2016 3:01:58 PM ONLY APPROVED ROOF NAILING, NEED TO CALL BRACING AND TIES.
TIE BEAM / LINTEL 05/27/2016 APPROVED LMILLER
FOUND SURVEY APPROVED (OFFICE) 05/26/2016 APPROVED FREODICA
LATH/BRICK/ WATER BARRIER 05/23/2016 CANCELLED BY APPLICANT JCOLASANTI
MONOLITHIC SLAB 05/06/2016 APPROVED - AS NOTED JCOLASANTI
Note: THIS IS A REINSPECTION Inspection Resulted at 5/6/2016 1:33:33 PM NEED COMPACTION STICKER ON SITE AT TIME OF NEXT INSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 05/03/2016 APPROVED JCOLASANTI
MONOLITHIC SLAB 05/02/2016 Disapproved - NO FEE JCOLASANTI
Note: Inspection Resulted at 5/2/2016 10:24:38 AM NEED TO PASS FIRST ROUGH PLUMBING BEFORE MONOLITHIC SLAB INSPECTION CAN BE CALLED IN FOR INSPECTION.

Review History

Department Status Date In Date Out
SW1 COMPLETE 12/07/2016 12/07/2016
Note: Released By: FREODICA Revised final survey
SW1 HOLD 12/01/2016 12/05/2016
Note: Held By: FREODICA revised final survey Fnal survey does not show positive drainage from the rear to the front at the left side of the property.
SW1 HOLD 11/18/2016 11/22/2016
Note: Held By: JHINDMAN final survey does not show positive drainage from the rear to the front of the property.
ELEC COMPLETE 07/11/2016 07/11/2016
ELEC HOLD 07/08/2016 07/08/2016
Note: Provide a signed and sealed plan or the signature and license number of the electrical contractor, FBC 105.3.1.2. Disconnect is needed for water heater, NEC 2011 422 part three. Disconnect is needed for AHU due to it being enclosed(not readily accessible), NEC 2011 440.14. -DC. Rewis 986-4736
SW1 COMPLETE 05/25/2016 05/26/2016
Note: Released By: FREODICA foundation s
ELEC COMPLETE 03/28/2016 03/28/2016
BLD COMPLETE 03/23/2016 03/28/2016
URB COMPLETE 03/23/2016 03/23/2016
ELEC HOLD 03/23/2016 03/24/2016
Note: Please add additional GFCI to counter top per NEC 2011 210.52 C, be advised Electrical Contractor can add GFCIs to plan along with a signature and license number. -DC. Rewis 986-4736
ZON COMPLETE 03/23/2016 03/24/2016
ELEC HOLD 03/17/2016 03/17/2016
Note: Per hold comment 3/11/2016: Please provide additional GFCIs on kitchen counter tops, NEC 2011 210.52 C. -DC. Rewis 986-4736
URB HOLD 03/17/2016 03/17/2016
Note: Understory trees need to be 30 gal. See LDC 11.03.03 A table 11 - 3.
PLUM COMPLETE 03/17/2016 03/17/2016
MECH COMPLETE 03/17/2016 03/17/2016
BLD HOLD 03/17/2016 03/17/2016
Note: 1. The insulation R-value for concrete wall in energy calculation shows 7.1 but Wall Section 5/4 shows 5. Both must match. Coordinate for clarity per FBC 5th ed. 107.2.1 2nd request J. Hindman 986-3784.
ZON HOLD 03/17/2016 03/18/2016
Note: Revise elevation page of plans to show the banding wrapping the front corners of the home for a minimum of 2'.
BLD HOLD 03/11/2016 03/14/2016
Note: 1. The insulation R-value for concrete wall in energy calculation shows 7.1 but Wall Section 5/4 shows 5. Coordinate for clarity per FBC 5th ed. 107.2.1. 2. Provide Interior Non-load Bearing Wall Section and Garage Wall Section designed per FBC 5th ed. (2014). 3. Provide Florida licensed roofing contractor per FS 489. F.N.Reodica - 386.986-4734.
ELEC HOLD 03/11/2016 03/11/2016
Note: Please provide load calculations and additional GFCIs on kitchen counter tops per NEC 2011.52 C. -DC. Rewis 986-4736
ENGIN1 COMPLETE 03/11/2016 03/16/2016
MECH HOLD 03/11/2016 03/14/2016
Note: 1. Provide heating and cooling load calculations for equipment sizing, manufacturer and model number of outdoor and indoor units and performance data on sensible and total cooling capacities per FBCEC 5th ed. R403.6.1. 2. Provide Energy Performance Level (EPL) display card with signature of the builder per FBCEC 5th ed. R405.4.3. F.N.Reodica -386-986-4734.
PLUM HOLD 03/11/2016 03/14/2016
Note: Provide sanitary riser diagram with signature and license number of plumbing contractor per FBC 5th ed. 107.2.1. F.N.Reodica -386-986-4734.
SW1 COMPLETE 03/11/2016 03/11/2016
UD1 COMPLETE 03/11/2016 03/14/2016
Note: See Notes
ZON HOLD 03/11/2016 03/14/2016
Note: 1. Provide site plan on separate page from landscape plan. 2. Banding on front of home must wrap corner for at least 2'.
URB HOLD 03/11/2016 03/11/2016
Note: 1: Need 3 gallon shrubbery along foundation 3ft on center and wrap corners. 2: Understory trees must be 30 gallon container size per the LDC.11/03.03 A table 11-3 3: If using a site plan for a landscaping must write in BOLD: For Landscape Use Only as a header on the plan.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00 12/28/2016
REINSPECTION FEE ¤40.00 12/28/2016
REINSPECTION FEE ¤40.00 12/28/2016
REINSPECTION FEE ¤40.00 12/28/2016
NEW RESIDENTIAL INSPECTIONS ¤590.00 03/29/2016
SITE PLAN 20 ¤20.00 03/29/2016
SURCHARGE FS 533.721 ¤21.91 03/29/2016
SURCHARGE - FS 468.631 ¤21.91 03/29/2016
STORM WATER PERMIT FEES ¤80.00 03/29/2016
3% TRANS IMPACT FEE CREDIT (¤93.74) 03/29/2016
ELECTRIC FEE ¤237.00 03/29/2016
3% FIRE IMPACT FEE CREDIT (¤6.38) 03/29/2016
IMPACT FEE FIRE NONRESIDENTIAL ¤212.80 03/29/2016
IMPACT FEE PARKS ¤849.24 03/29/2016
IMPACT FEE SCHOOL ¤3,600.00 03/29/2016
IMPACT FEE TRANSPORTATION ¤3,124.67 03/29/2016
MECHANICAL FEE ¤237.00 03/29/2016
3% PARKS IMPACT FEE CREDIT (¤25.48) 03/29/2016
PLAN CHECK FEE ¤118.00 03/29/2016
PLUMBING FEE ¤237.00 03/29/2016
ADMIN FEE ¤20.00 03/29/2016
Fees Total Due: ¤0.00 Total Paid: ¤9,403.93