I want to search for...

Permit #2016030838

Permit Details

Status: COED

Parcel Id: 42-10-30-3210-00000-2710
GARAGE: 765 sqft
OPENED PORCH (WITH ROOF) : 70 sqft
ALUMINUM ENCLOSURE (SCREEN ROOF) : 405 sqft
CONDITIONED SPACE: 2981 sqft
Total Square Footage: 4221 sqft
Block: 00000
Subdivision: 2094 - CONSERVATORY AT HAMMOCK BEACH
Job Phone: 386-947-4481
Location Address: 504 SWEETGUM LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/12/2016
NOC: RECORDED
Applicant name: ERIC CHRISTOPHER OLSEN
Owner: RAUSEO, PAUL & VICTORIA

Address

504 SWEETGUM LANE

PALM COAST, FL 32137

Lot: 2710
Contracted Stated Job Value: ¤416,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

OLSEN CUSTOM HOMES AND CONSULTING INC
Status Location Address State License Number Phone Fax
ACTIVE

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

CGC1508852 (Exp: 08/31/2026) 386-947-4481 (386)947-4484

Sub Contractors

BENJAMIN EDWARD SMITH
Status Location Address State License Number Phone
CANCEL

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

EC13004288 (Exp: 08/31/2016) 386-265-2687
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32136

CAC048127 (Exp: 08/31/2018) 386-445-5023 386-446-4614
JOHN BRADLEY WINFREY JR
Status Location Address State License Number Phone Fax
ACTIVE

1685 S. CLARA AVE

Deland, FL 32720

CFC054901 (Exp: 08/31/2026) 386-734-0154 386-734-2751
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 11/23/2016 FINAL APPROVED MBACON
Note: Per our conversation Carl with Olsen Homes will replace 4 inch clean out cap with flush mount style.
BLD - BUILDING FINAL 11/22/2016 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 11/21/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: THIS IS A REINSPECTION AHU breakers need to be marked correctly....check hot water system....paint needs to be complete...weather stripping needs to be placed....baffles need to be placed in attic access
GAS ROUGH 11/21/2016 APPROVED JCOLASANTI
GAS FINAL 11/21/2016 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
GAS FINAL 11/18/2016 Disapproved - NO FEE JCOLASANTI
Note: need access to residence to complete inspection
FINAL APRON (AFTER POUR/DRIVEWAY) 11/18/2016 APPROVED RGROSS
Note: THIS IS A REINSPECTION. APPROVED
ROW FINAL 11/18/2016 APPROVED RGROSS
Note: APPROVED
BLD - BUILDING FINAL 11/18/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: Doors Locked, need access to residence to complete inspection, checked all doors and slider...(note exterior paint will need to be completed for final inspection)
PRE-APRON (PRE-POUR/DRIVEWAY) 11/17/2016 APPROVED RGROSS
Note: THIS IS A REINSPECTION. READY TO POUR AND PLACE PAVERS.
FINAL APRON (AFTER POUR/DRIVEWAY) 11/08/2016 Disapproved -FEE REQUIRED GLALIMA
Note: NO PRE POUR .ALSO NEED TO SEE LOCATION OF 4" PVC DRAINAGE COMING OUT OF GROUND . IF SITE MEET NEEDED CALL GARY 386-585-0287
PRE-APRON (PRE-POUR/DRIVEWAY) 11/08/2016 Disapproved -FEE REQUIRED GLALIMA
Note: REMOVE 16' FEET FROM ROAD EDGE BACK OF PAVERS AND CONCRETE PAVER RESTRAINTS, NOT TO CODE, NO PRE INSPECTIONS, AND NO CALL BACKS
FINAL SURVEY (OFFICE USE ONLY) 11/07/2016 APPROVED FREODICA
ELECTRIC - EARLY POWER 09/12/2016 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO FPL RELEASED EARLY POWER 1:00 CHECK ENTERTAINMENT CENTRE OUTLETS ON FINAL, CABINET CONTRACTOR TOOK PLATES OFF TO INSTALL CABINETS
GRAVITY SEWER TEST 08/11/2016 APPROVED CMINI
Note: THIS IS A REINSPECTION
GRAVITY SEWER TEST 08/10/2016 CANCELLED BY APPLICANT CMINI
U - SEWER TIE IN 08/10/2016 APPROVED MBACON
Note: THIS IS A REINSPECTION
INSULATION 08/10/2016 APPROVED CMINI
ALL ROUGH 08/03/2016 APPROVED - AS NOTED JCOLASANTI
Note: THIS IS A REINSPECTION will need to call in tub set inspection.......ail plate above switch in garage marked on wall. will check at insulation
ALL ROUGH 08/02/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: screw arch windows, seal chase pipe....NEED TO PHASE OUT HOT CONDUCTORS IN PANEL.210.5(C ....nail plates condensate lineswitch garage, security wires at windows...need to bond gas pipe
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/29/2016 APPROVED - AS NOTED JCOLASANTI
Note: CHECK FOR TIE DOWN AT BEARING OPENING (will check at all rough inspection
LATH/BRICK/ WATER BARRIER 07/27/2016 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 07/25/2016 Disapproved -FEE REQUIRED CMINI
Note: corner bead needs to be 7/8" over wood for correct thickness. per ASTM C926 standards under wood.. 3/8"+3/8"+1/8"
WALL SHEATHING 07/13/2016 APPROVED LMILLER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/12/2016 APPROVED - AS NOTED JCOLASANTI
Note: THIS IS A REINSPECTION Inspection Resulted at 7/12/2016 3:51:44 PM CHECK FOR TIE DOWN AT BEARING OPENING
ELECTRIC-TUG 06/14/2016 APPROVED - AS NOTED RMARTIN
Note: Inspection Resulted at 6/14/2016 2:22:12 PM SPOKE TO SUSAN FPL RELEASED TUG 2:10
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/08/2016 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 6/8/2016 10:28:51 AM BUMPED ROOF, OK TO DRY IN. NOT READY FOR TIE DOWN BRACES AND DOWN CELL, MISSING CONTINUOUS LOAD PATH, A CONTINUOUS LOAD PATH SHALL BE PROVIDED TO TRANSMIT THE APPLICABLE UPLIFT FORCES IN SECTION R802.2 FROM THE ROOF ASSEMBLY TO THE FOUNDATION.CHECK ALL. FBC R301.2.1
TIE BEAM / LINTEL 05/24/2016 APPROVED JCOLASANTI
FOUND SURVEY APPROVED (OFFICE) 05/11/2016 APPROVED DREWIS
MONOLITHIC SLAB 05/05/2016 APPROVED CMINI
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 05/04/2016 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 5/4/2016 9:57:34 AM NOT READY FOR INSPECTION, STILL INSTALLING STEEL, NEED TO CLEAN OUT CAVE IN AT FOOTERS. SHOWER FORMS NOT INSTALLED YET
MONOLITHIC SLAB 05/03/2016 CANCELLED BY APPLICANT AIRS WEB
PLUMBING 1ST ROUGH UNDERGROUND 04/26/2016 FINAL APPROVED CMINI
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 04/25/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 4/25/2016 2:15:01 PM ANY WATER PIPING SYSTEM CONSTRUCTED OF PLASTIC MUST BE TESTED UNDER WATER PRESSURE. WATER SHALL BE HELD FOR A PERIOD OF 15 MINUTES.P2503.7
U - SEWER TIE IN 04/25/2016 Disapproved - NO FEE JNICHOLS
Note: Inspection Resulted at 4/25/2016 10:59:41 AM THE CLEAN-OUT NEEDS TO BE ON THE FLAT PIECE. CANNOT BE ON THE PIECE GOING DOWN. IF SOMEONE DRIVES OVER IT, IT IS EASIER TO REPLACE OR FIX IT IF IT IS 1 TO 2 FEET DEEP.OPPOSED TO BEING 4-5 FEET DEEP OR EVEN A BROKEN WYE.

Review History

Department Status Date In Date Out
SW1 COMPLETE 11/04/2016 11/07/2016
Note: Released By: FREODICA FINAL S
ZON HOLD 08/02/2016 08/02/2016
Note: REPEAT COMMENT: Site plan originally approved by Zoning with the new house submittal did not depict an LP tank. Provide revised survey/site plan locating the proposed tank. Be sure to include its size and setback information.
PLUM COMPLETE 08/02/2016 08/03/2016
Note: Revision: gas riser diagram was previously completed on 7-14-16.
PLUM COMPLETE 07/12/2016 07/14/2016
Note: Revision: added gas piping and 120- gallon, u/g propane gas tank. See gas riser diagram.
ZON HOLD 07/12/2016 07/13/2016
Note: Site plan originally approved by Zoning with the new house submittal did not depict an LP tank. Provide revised survey/site plan locating the proposed tank. Be sure to include its size and setback information.
SW1 COMPLETE 05/11/2016 05/11/2016
Note: Released By: DREWIS Foundation survey
ELEC COMPLETE 04/08/2016 04/08/2016
BLD COMPLETE 04/08/2016 04/08/2016
ELEC HOLD 04/04/2016 04/04/2016
Note: Per hold from 3/29: Provide code reference. Provide a receptacle in hallway to master bathroom, NEC 2011 210.52H. -DC. Rewis 986-4736
MECH COMPLETE 04/04/2016 04/04/2016
BLD COMPLETE 04/04/2016 04/04/2016
ZON COMPLETE 04/04/2016 04/06/2016
BLD HOLD 03/28/2016 03/28/2016
Note: Clarify if fireplace would be installed as it is not shown on floor plan but shown on gas riser diagram. Coordinate and if is needed, provide manufacturer's specifications and installation per FBC 5th ed. 107.2.1. F.N.Reodica -386-986-4734.
ELEC HOLD 03/28/2016 03/28/2016
Note: Please provide the following: Referenced code. GFCI for vanity in bathroom next to bedroom #2, NEC 2011 210.52D. Receptacle within the hallway to master bedroom, NEC 2011 210.52H. -DC. Rewis 986-4736
ENGIN1 COMPLETE 03/28/2016 03/28/2016
Note: Road is designed with curb and gutter. No swale plan is required.
MECH HOLD 03/28/2016 03/28/2016
Note: Hvac plan is flipped (garage on left). Coordinate with floor plan for clarity per FBC 5th ed. 107.2.1. F.N.Reodica -386-986-4734.
PLUM COMPLETE 03/28/2016 03/28/2016
SW1 COMPLETE 03/28/2016 03/28/2016
UD1 COMPLETE 03/28/2016 03/29/2016
Note: See Notes
ZON HOLD 03/28/2016 03/30/2016
Note: Garage Door Color does not meet the LRV of 25 or greater. Revise site plan to show rear setback from house to property line. Revise landscaping plan to show around rear of house not proposed pool.
URB COMPLETE 03/28/2016 03/29/2016
ZON PENDING

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 11/23/2016
REINSPECTION FEE ¤40.00 11/23/2016
REINSPECTION FEE ¤40.00 11/23/2016
REINSPECTION FEE ¤40.00 11/23/2016
REINSPECTION FEE ¤40.00 11/23/2016
REINSPECTION FEE ¤40.00 11/23/2016
REINSPECTION FEE ¤40.00 11/23/2016
REINSPECTION FEE ¤40.00 11/23/2016
REINSPECTION FEE ¤40.00 11/23/2016
REVISION ¤40.00 11/23/2016
SITE PLAN 20 ¤20.00 04/12/2016
SURCHARGE FS 533.721 ¤29.96 04/12/2016
SURCHARGE - FS 468.631 ¤29.96 04/12/2016
STORM WATER PERMIT FEES ¤80.00 04/12/2016
3% TRANS IMPACT FEE CREDIT (¤93.74) 04/12/2016
NEW RESIDENTIAL INSPECTIONS ¤832.00 04/12/2016
ADMIN FEE ¤20.00 04/12/2016
ELECTRIC FEE ¤309.60 04/12/2016
3% FIRE IMPACT FEE CREDIT (¤6.38) 04/12/2016
IMPACT FEE FIRE NONRESIDENTIAL ¤212.80 04/12/2016
IMPACT FEE PARKS ¤849.24 04/12/2016
IMPACT FEE SCHOOL ¤3,600.00 04/12/2016
IMPACT FEE TRANSPORTATION ¤3,124.67 04/12/2016
MECHANICAL FEE ¤309.60 04/12/2016
3% PARKS IMPACT FEE CREDIT (¤25.48) 04/12/2016
PLAN CHECK FEE ¤166.40 04/12/2016
PLUMBING FEE ¤309.60 04/12/2016
Fees Total Due: ¤0.00 Total Paid: ¤10,168.23