Permit #2016030838
Permit Details
Status: COED
| Parcel Id: 42-10-30-3210-00000-2710 |
| GARAGE: 765 sqft |
| OPENED PORCH (WITH ROOF) : 70 sqft |
| ALUMINUM ENCLOSURE (SCREEN ROOF) : 405 sqft |
| CONDITIONED SPACE: 2981 sqft |
| Total Square Footage: 4221 sqft |
| Block: 00000 |
| Subdivision: 2094 - CONSERVATORY AT HAMMOCK BEACH |
| Job Phone: 386-947-4481 |
| Location Address: 504 SWEETGUM LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/12/2016 |
| NOC: RECORDED |
| Applicant name: ERIC CHRISTOPHER OLSEN |
| Owner: RAUSEO, PAUL & VICTORIA |
|
Address 504 SWEETGUM LANE PALM COAST, FL 32137 |
| Lot: 2710 |
| Contracted Stated Job Value: ¤416,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
OLSEN CUSTOM HOMES AND CONSULTING INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
CGC1508852 (Exp: 08/31/2026) | 386-947-4481 | (386)947-4484 |
Sub Contractors
BENJAMIN EDWARD SMITH
| Status | Location Address | State License Number | Phone |
| CANCEL |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
EC13004288 (Exp: 08/31/2016) | 386-265-2687 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32136 |
CAC048127 (Exp: 08/31/2018) | 386-445-5023 | 386-446-4614 |
JOHN BRADLEY WINFREY JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1685 S. CLARA AVE Deland, FL 32720 |
CFC054901 (Exp: 08/31/2026) | 386-734-0154 | 386-734-2751 |
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 11/23/2016 | FINAL APPROVED | MBACON |
| Note: Per our conversation Carl with Olsen Homes will replace 4 inch clean out cap with flush mount style. | |||
| BLD - BUILDING FINAL | 11/22/2016 | FINAL APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 11/21/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: THIS IS A REINSPECTION AHU breakers need to be marked correctly....check hot water system....paint needs to be complete...weather stripping needs to be placed....baffles need to be placed in attic access | |||
| GAS ROUGH | 11/21/2016 | APPROVED | JCOLASANTI |
| GAS FINAL | 11/21/2016 | FINAL APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| GAS FINAL | 11/18/2016 | Disapproved - NO FEE | JCOLASANTI |
| Note: need access to residence to complete inspection | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | 11/18/2016 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION. APPROVED | |||
| ROW FINAL | 11/18/2016 | APPROVED | RGROSS |
| Note: APPROVED | |||
| BLD - BUILDING FINAL | 11/18/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Doors Locked, need access to residence to complete inspection, checked all doors and slider...(note exterior paint will need to be completed for final inspection) | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 11/17/2016 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION. READY TO POUR AND PLACE PAVERS. | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | 11/08/2016 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: NO PRE POUR .ALSO NEED TO SEE LOCATION OF 4" PVC DRAINAGE COMING OUT OF GROUND . IF SITE MEET NEEDED CALL GARY 386-585-0287 | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 11/08/2016 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: REMOVE 16' FEET FROM ROAD EDGE BACK OF PAVERS AND CONCRETE PAVER RESTRAINTS, NOT TO CODE, NO PRE INSPECTIONS, AND NO CALL BACKS | |||
| FINAL SURVEY (OFFICE USE ONLY) | 11/07/2016 | APPROVED | FREODICA |
| ELECTRIC - EARLY POWER | 09/12/2016 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO FPL RELEASED EARLY POWER 1:00 CHECK ENTERTAINMENT CENTRE OUTLETS ON FINAL, CABINET CONTRACTOR TOOK PLATES OFF TO INSTALL CABINETS | |||
| GRAVITY SEWER TEST | 08/11/2016 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| GRAVITY SEWER TEST | 08/10/2016 | CANCELLED BY APPLICANT | CMINI |
| U - SEWER TIE IN | 08/10/2016 | APPROVED | MBACON |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 08/10/2016 | APPROVED | CMINI |
| ALL ROUGH | 08/03/2016 | APPROVED - AS NOTED | JCOLASANTI |
| Note: THIS IS A REINSPECTION will need to call in tub set inspection.......ail plate above switch in garage marked on wall. will check at insulation | |||
| ALL ROUGH | 08/02/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: screw arch windows, seal chase pipe....NEED TO PHASE OUT HOT CONDUCTORS IN PANEL.210.5(C ....nail plates condensate lineswitch garage, security wires at windows...need to bond gas pipe | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/29/2016 | APPROVED - AS NOTED | JCOLASANTI |
| Note: CHECK FOR TIE DOWN AT BEARING OPENING (will check at all rough inspection | |||
| LATH/BRICK/ WATER BARRIER | 07/27/2016 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 07/25/2016 | Disapproved -FEE REQUIRED | CMINI |
| Note: corner bead needs to be 7/8" over wood for correct thickness. per ASTM C926 standards under wood.. 3/8"+3/8"+1/8" | |||
| WALL SHEATHING | 07/13/2016 | APPROVED | LMILLER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/12/2016 | APPROVED - AS NOTED | JCOLASANTI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/12/2016 3:51:44 PM CHECK FOR TIE DOWN AT BEARING OPENING | |||
| ELECTRIC-TUG | 06/14/2016 | APPROVED - AS NOTED | RMARTIN |
| Note: Inspection Resulted at 6/14/2016 2:22:12 PM SPOKE TO SUSAN FPL RELEASED TUG 2:10 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/08/2016 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 6/8/2016 10:28:51 AM BUMPED ROOF, OK TO DRY IN. NOT READY FOR TIE DOWN BRACES AND DOWN CELL, MISSING CONTINUOUS LOAD PATH, A CONTINUOUS LOAD PATH SHALL BE PROVIDED TO TRANSMIT THE APPLICABLE UPLIFT FORCES IN SECTION R802.2 FROM THE ROOF ASSEMBLY TO THE FOUNDATION.CHECK ALL. FBC R301.2.1 | |||
| TIE BEAM / LINTEL | 05/24/2016 | APPROVED | JCOLASANTI |
| FOUND SURVEY APPROVED (OFFICE) | 05/11/2016 | APPROVED | DREWIS |
| MONOLITHIC SLAB | 05/05/2016 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB | 05/04/2016 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 5/4/2016 9:57:34 AM NOT READY FOR INSPECTION, STILL INSTALLING STEEL, NEED TO CLEAN OUT CAVE IN AT FOOTERS. SHOWER FORMS NOT INSTALLED YET | |||
| MONOLITHIC SLAB | 05/03/2016 | CANCELLED BY APPLICANT | AIRS WEB |
| PLUMBING 1ST ROUGH UNDERGROUND | 04/26/2016 | FINAL APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/25/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 4/25/2016 2:15:01 PM ANY WATER PIPING SYSTEM CONSTRUCTED OF PLASTIC MUST BE TESTED UNDER WATER PRESSURE. WATER SHALL BE HELD FOR A PERIOD OF 15 MINUTES.P2503.7 | |||
| U - SEWER TIE IN | 04/25/2016 | Disapproved - NO FEE | JNICHOLS |
| Note: Inspection Resulted at 4/25/2016 10:59:41 AM THE CLEAN-OUT NEEDS TO BE ON THE FLAT PIECE. CANNOT BE ON THE PIECE GOING DOWN. IF SOMEONE DRIVES OVER IT, IT IS EASIER TO REPLACE OR FIX IT IF IT IS 1 TO 2 FEET DEEP.OPPOSED TO BEING 4-5 FEET DEEP OR EVEN A BROKEN WYE. |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 11/04/2016 | 11/07/2016 |
| Note: Released By: FREODICA FINAL S | |||
| ZON | HOLD | 08/02/2016 | 08/02/2016 |
| Note: REPEAT COMMENT: Site plan originally approved by Zoning with the new house submittal did not depict an LP tank. Provide revised survey/site plan locating the proposed tank. Be sure to include its size and setback information. | |||
| PLUM | COMPLETE | 08/02/2016 | 08/03/2016 |
| Note: Revision: gas riser diagram was previously completed on 7-14-16. | |||
| PLUM | COMPLETE | 07/12/2016 | 07/14/2016 |
| Note: Revision: added gas piping and 120- gallon, u/g propane gas tank. See gas riser diagram. | |||
| ZON | HOLD | 07/12/2016 | 07/13/2016 |
| Note: Site plan originally approved by Zoning with the new house submittal did not depict an LP tank. Provide revised survey/site plan locating the proposed tank. Be sure to include its size and setback information. | |||
| SW1 | COMPLETE | 05/11/2016 | 05/11/2016 |
| Note: Released By: DREWIS Foundation survey | |||
| ELEC | COMPLETE | 04/08/2016 | 04/08/2016 |
| BLD | COMPLETE | 04/08/2016 | 04/08/2016 |
| ELEC | HOLD | 04/04/2016 | 04/04/2016 |
| Note: Per hold from 3/29: Provide code reference. Provide a receptacle in hallway to master bathroom, NEC 2011 210.52H. -DC. Rewis 986-4736 | |||
| MECH | COMPLETE | 04/04/2016 | 04/04/2016 |
| BLD | COMPLETE | 04/04/2016 | 04/04/2016 |
| ZON | COMPLETE | 04/04/2016 | 04/06/2016 |
| BLD | HOLD | 03/28/2016 | 03/28/2016 |
| Note: Clarify if fireplace would be installed as it is not shown on floor plan but shown on gas riser diagram. Coordinate and if is needed, provide manufacturer's specifications and installation per FBC 5th ed. 107.2.1. F.N.Reodica -386-986-4734. | |||
| ELEC | HOLD | 03/28/2016 | 03/28/2016 |
| Note: Please provide the following: Referenced code. GFCI for vanity in bathroom next to bedroom #2, NEC 2011 210.52D. Receptacle within the hallway to master bedroom, NEC 2011 210.52H. -DC. Rewis 986-4736 | |||
| ENGIN1 | COMPLETE | 03/28/2016 | 03/28/2016 |
| Note: Road is designed with curb and gutter. No swale plan is required. | |||
| MECH | HOLD | 03/28/2016 | 03/28/2016 |
| Note: Hvac plan is flipped (garage on left). Coordinate with floor plan for clarity per FBC 5th ed. 107.2.1. F.N.Reodica -386-986-4734. | |||
| PLUM | COMPLETE | 03/28/2016 | 03/28/2016 |
| SW1 | COMPLETE | 03/28/2016 | 03/28/2016 |
| UD1 | COMPLETE | 03/28/2016 | 03/29/2016 |
| Note: See Notes | |||
| ZON | HOLD | 03/28/2016 | 03/30/2016 |
| Note: Garage Door Color does not meet the LRV of 25 or greater. Revise site plan to show rear setback from house to property line. Revise landscaping plan to show around rear of house not proposed pool. | |||
| URB | COMPLETE | 03/28/2016 | 03/29/2016 |
| ZON | PENDING |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 11/23/2016 |
| REINSPECTION FEE | ¤40.00 | 11/23/2016 |
| REINSPECTION FEE | ¤40.00 | 11/23/2016 |
| REINSPECTION FEE | ¤40.00 | 11/23/2016 |
| REINSPECTION FEE | ¤40.00 | 11/23/2016 |
| REINSPECTION FEE | ¤40.00 | 11/23/2016 |
| REINSPECTION FEE | ¤40.00 | 11/23/2016 |
| REINSPECTION FEE | ¤40.00 | 11/23/2016 |
| REINSPECTION FEE | ¤40.00 | 11/23/2016 |
| REVISION | ¤40.00 | 11/23/2016 |
| SITE PLAN 20 | ¤20.00 | 04/12/2016 |
| SURCHARGE FS 533.721 | ¤29.96 | 04/12/2016 |
| SURCHARGE - FS 468.631 | ¤29.96 | 04/12/2016 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/12/2016 |
| 3% TRANS IMPACT FEE CREDIT | (¤93.74) | 04/12/2016 |
| NEW RESIDENTIAL INSPECTIONS | ¤832.00 | 04/12/2016 |
| ADMIN FEE | ¤20.00 | 04/12/2016 |
| ELECTRIC FEE | ¤309.60 | 04/12/2016 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.38) | 04/12/2016 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤212.80 | 04/12/2016 |
| IMPACT FEE PARKS | ¤849.24 | 04/12/2016 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 04/12/2016 |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | 04/12/2016 |
| MECHANICAL FEE | ¤309.60 | 04/12/2016 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 04/12/2016 |
| PLAN CHECK FEE | ¤166.40 | 04/12/2016 |
| PLUMBING FEE | ¤309.60 | 04/12/2016 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,168.23 |