I want to search for...

Permit #2016040508

Permit Details

Status: CANCEL

Parcel Id: 07-11-31-7013-RP N -0070
Block: RP N
Subdivision: 2249 - ST JOE BUSINESS CENTER
Job Phone: (386)986-2224
Location Address: 4982 PALM COAST PKWY NW
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
NOC: NO DOCUMENTATION
Applicant name: WILLIAM P WHITLEY III
Owner: ST JOE BUSINESS CENTER INC

Address

4 HICKORY DRIVE

OLD BROOKVILLE, NY 11545

Lot: 0070
Contracted Stated Job Value: ¤30,000.00
Job Description: UNIT # 8 - 9 "CLUB MIRAGE"
Type: CN

Contractor

WHITLEY BUILDERS LLC
Status Location Address State License Number Phone
CANCEL

6 BUTTONWELL LANE

PALM COAST, FL 32137

CBC1255213 (Exp: 08/31/2018) (386)986-2224

Sub Contractors

JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144
JOHN ROBERT BLEVINS JR
Status Location Address State License Number Phone Fax
ACTIVE

17 PORWYN LANE

PALM COAST, FL 32164

CAC1816125 (Exp: 08/31/2026) 386-585-8283 386-263-2096
LEONARD EDWARD GASPARY
Status Location Address State License Number Phone Fax
INACTIVE

400 N US HWY 1

HOLLY HILL , FL 32117

CFC057799 (Exp: 08/31/2026) 386-672-8494 386-673-7856

Inspection History

Type Request Date Result Inspector
ABOVE CEILING
BUILDING FINAL
FIRE FINAL
U - UTILITY COMMERCIAL FINAL

Review History

Department Status Date In Date Out
MECH COMPLETE 05/18/2016 05/18/2016
PLUM HOLD 05/18/2016 05/18/2016
Note: Repeat comment Previous comment item 2 shall be addressed. 2. Hand sink and lavatories shall be connected and vented per FBCP 5th ed. 905.3/905.4. Please note the comment above refers to 3 lavatories upstream of mop sink and a hand sink downstream of 3- compartment sink.
ELEC COMPLETE 05/05/2016 05/06/2016
BLD COMPLETE 05/05/2016 05/05/2016
FI1 COMPLETE 05/05/2016 05/05/2016
MECH HOLD 05/05/2016 05/06/2016
Note: Response to previous comments 2 and 4 need more clarifications. See additional comment. 2. Identify the air handling units (AHU(s) ) on hvac plan clarity per FBC 5th ed. 107.2.1. Comment: Name designation of air handling units shall be indicated on plan to match with those on load calculations. 4. Provide hvac equipment specifications as to cooling capacity, sensible, latent and efficiency to determine if they can handle the calculated loads per FBCEC 5th ed. C403.2.1. F.N.Reodica-386-986-4734. Comment: The capacity of hvac units exceeds the 40% of calculated total cooling load which does not comply with FBCEC 5th ed. C403.2.2.
PLUM HOLD 05/05/2016 05/09/2016
Note: Previous comment item 2 shall be addressed. 2. Hand sink and lavatories shall be connected and vented per FBCP 5th ed. 905.3/905.4.
BLD HOLD 04/15/2016 04/15/2016
Note: 1.Provide accessibility compliance at the bar and any seating areas per the 5th ed. FBC existing Building 1012.8 and 5th ed. FBC accessibility 202.1. 2.Provide exit doors that comply with the 5th ed. FBC 1008.1.10. J. Hindman 986-3784.
ELEC HOLD 04/15/2016 04/15/2016
Note: Please depict existing lighting and provide lighting to storage area, NEC 2011 210.70. -DC. Rewis 986-4736
FI1 HOLD 04/15/2016 04/15/2016
Note: 1. Provide dimensions for the non-fixed seating to comply with The Florida Fire Prevention code 101 12.2.5. for aisle accessways and aisles serving seating at tables. J. Hindman 986-3784.
MECH HOLD 04/15/2016 04/20/2016
Note: 1. Provide signature and license number of hvac contractor on hvac plan per FBC 5th ed. 107.2.1 2. Identify the air handling units (AHU(s) ) on hvac plan and indicate if they are existing or new units for clarity per FBC 5th ed. 107.2.1. 3. Provide make up air or outdoor air duct layout including duct sizes for each AHU per FBCM 5th ed. 403.2. 4. Provide hvac equipment specifications as to cooling capacity, sensible, latent and efficiency to determine if they can handle the calculated loads per FBCEC 5th ed. C403.2.1. F.N.Reodica-386-986-4734.
PLUM HOLD 04/15/2016 04/20/2016
Note: 1. Provide plumbing plan or layout to determine that the riser diagram matches the plan for clarity per FBC 5th ed. 107.2.1. 2. Hand sink and lavatories shall be connected and vented per FBCP 5th ed. 905.3/905.4. 3. Provide vent for the urinal per FBCP 5th ed. 910.1. F.N.Reodica-386-986-4734.
UD1 COMPLETE 04/15/2016 04/18/2016
ZON COMPLETE 04/15/2016 04/15/2016
SW1 COMPLETE 04/15/2016 04/15/2016
PLUM CANCEL