Permit #2016040655

Permit Details

Status: COED

Parcel Id: 15-11-31-2832-00000-0940
CONDITIONED SPACE: 2828 sqft
GARAGE: 486 sqft
OPENED PORCH (WITH ROOF) : 228 sqft
OPENED PORCH (WITH ROOF) : 156 sqft
OPENED PORCH (WITH ROOF) : 109 sqft
Total Square Footage: 3807 sqft
Block: 00000
Subdivision: 1072 - FRONT STREET @ GRAND HAVEN PHASE 2
Job Phone: 386-947-4481
Location Address: 88 FRONT ST
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/06/2016
NOC: RECORDED
Applicant name: ERIC CHRISTOPHER OLSEN
Owner: MARK A LEO & KATHY M REICHARD-ELLAVSKY

Address

88 FRONT ST

PALM COAST, FL 32137

Lot: 0940
Contracted Stated Job Value: ¤397,964.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

OLSEN CUSTOM HOMES AND CONSULTING INC
Status Location Address State License Number Phone Fax
ACTIVE

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

CGC1508852 (Exp: 08/31/2026) 386-947-4481 (386)947-4484

Sub Contractors

BENJAMIN EDWARD SMITH
Status Location Address State License Number Phone
CANCEL

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

EC13004288 (Exp: 08/31/2016) 386-265-2687
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32136

CAC048127 (Exp: 08/31/2018) 386-445-5023 386-446-4614
JOHN BRADLEY WINFREY JR
Status Location Address State License Number Phone Fax
ACTIVE

1685 S. CLARA AVE

Deland, FL 32720

CFC054901 (Exp: 08/31/2026) 386-734-0154 386-734-2751
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 01/13/2017 FINAL APPROVED JNICHOLS
Note: THIS IS A REINSPECTION
U -UTILITY RESIDENTIAL FINAL 01/12/2017 Disapproved - NO FEE JNICHOLS
Note: the water meter pit has trash in it from the construction. looks like some one swept up a pile of trash and dumped it in the pit. the sewer clean out needs tobe raised to be flush with the grade and a flat cap needs to be installed. being in the mulch bed it will get covered and will not be able to locate if needed.
ROW FINAL 01/09/2017 Disapproved -FEE REQUIRED RGROSS
Note: THIS IS A REINSPECTION. VACANT LOT NEEDS SEEDED. LOTS OF STRAW PLACED, BUT NO SEED. BARE EARTH NEAR BOTH PALM TREES NEED TO BE STABILIZED TO PREVENT SEDIMENT FROM WASHING OUT INTO THE CANAL. SEE PHOTO ATTACHED.
ROW FINAL 01/09/2017 APPROVED - AS NOTED RGROSS
Note: THIS IS A REINSPECTION. CONTRACTOR PUT SOD ALONG SEAWALL AND ADDED SEED TO VACANT LOT.
BLD - BUILDING FINAL 01/05/2017 FINAL APPROVED LMILLER
Note: THIS IS A REINSPECTION
ROW FINAL 01/05/2017 CANCELLED BY APPLICANT GLALIMA
Note: THIS IS A REINSPECTION
ROW FINAL 01/03/2017 Disapproved -FEE REQUIRED RGROSS
Note: SOD THE FIRST 15 FT FROM THE MIAMI CURB ALONG THE ENTIRE ADJACENT PROPERTY. SEED AND STRAW THE ENTIRE ADJACENT LOT BEYOND THE 15 FT FROM MIAMI CURB. REGRADE AND SOD THE FIRST 5 FEET OF THE SEAWALL. POOL CO. WILL SOD THE REST WHEN POOL IS FINISHED. REMOVE DUMPSTER AND PAVERS FROM THE ADJACENT LOT. CLEAN SAND AND DEBRI FROM THE MIAMI GUTTER ON BOTH THE CONSTRUCTION AND ADJACENT LOT. ON SITE WITH CONTRACTOR. NOTE: POOL IS STILL UNDER CONSTRUCTION. POOL BUILDER WILL BE RESPOSIBLE FOR ANY FURTHER DAMAGE TO ADJACENT PROPERTY.
BLD - BUILDING FINAL 01/03/2017 Disapproved -FEE REQUIRED LMILLER
Note: 1. NEED REVISION FOR ADDED ELECTRIC (CALLED FOR BY FINAL AND IS NOT ON SITE) 2. 3 inches AND SET LEVEL GROUND CLEARANCE, FOUNDATIONS AND SUPPORTS FBCM1403.2 EQUIPMENT AND APPLIANCES SHALL BE LEVEL AND FIRMLY SUPPORTED ON A CONCRETE PAD OR OTHER APPROVED MATERIAL EXTENDING NOT LESS THAN 3inches ABOVE THE ADJOINING GROUND 3. WORKING SPACE for electric equipment 26. E3405.2 36in. MINIMUM DEPTH AND 30in. MINIMUM WIDTH OR THE WIDTH OF THE EQUIPMENT (WICH EVER IS GREATER) 4. LEBELED GFCI OUTLET AT LEFT SIDE OF MASTER SINK (DIRECT SHORT) 5. HOT AND COLD WATER LOOPED (MUST REMOVE LOOP SO WE CAN CHECK HOT WATER PLACEMENT AT SINKS 6. PAN SIZE M1411.3.1 (1) AUXILIARY AND SECONDARY DRAIN SYSTEMSMUST NOT BE LESS THAN 3 1D LONGER AND WIDER 7.GARAGE DOOR SELF-CLOSING DEVICES R302.5.1 DOORS MUST BE EQUIPED WITH SELF-CLOSING DEVICE
FINAL APRON (AFTER POUR/DRIVEWAY) 12/29/2016 APPROVED CTROHA
Note: THIS IS A REINSPECTION WORK COMPLETE
FINAL SURVEY (OFFICE USE ONLY) 12/29/2016 APPROVED JHINDMAN
FINAL APRON (AFTER POUR/DRIVEWAY) 11/16/2016 Disapproved -FEE REQUIRED CTROHA
Note: MISSING DOCUMENTS: FINAL SURVEY TRIPPING HAZARD AT THE STREET PAVERS ARE HIGHER THAN MIAMI GUTTER ON RIGHT SIDE EDGE RESTRAINTS DO NOT MEET REQUIREMENTS SEE DRIVEWAY DETAIL
PRE-APRON (PRE-POUR/DRIVEWAY) 10/12/2016 APPROVED - AS NOTED RGROSS
Note: THIS IS A REINSPECTION. APRON FLARES MUST BE A MINIMUM OF 36 INCHES FOR THE FINAL.
ELECTRIC - EARLY POWER 10/03/2016 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 3:17
PRE-APRON (PRE-POUR/DRIVEWAY) 09/29/2016 Disapproved -FEE REQUIRED RGROSS
Note: SITE NOT READY FOR INSPECTION. NO SUB-BASE, NO FORM BOARDS IN PLACE, NO PAVERS ON SITE. PHOTO'S ON FILE.
INSULATION 08/25/2016 APPROVED CMINI
ALL ROUGH 08/23/2016 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION. need to support SER cable every 4-1/2' in attic, garage outlet not complete, open end. disconnect for AHU not complete, open wiring. missing 10' head. check on isulation
LATH/BRICK/ WATER BARRIER 08/19/2016 APPROVED DROCKWELL
ALL ROUGH 08/18/2016 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION 10ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.4, (EMPTY) NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE. (THROUGHOUT) GAS TIGHT FBC P3003.1 JOINTS AND CONNECTIONS IN THE DWV SYSTEM SHALL BE GAS TIGHT AND WATER TIGHT FOR THE INTENDED USE OR PRESSURE REQUIRED BY TEST (VTR NOT CONNECTED) CANNOT PLACE USED MATERIAL IN NEW CONSTRUCTION (LIVING ROOM CEILING PAINT COVERED LIGHT BOXES) NEED REVISION FOR ADDED ELECTRIC BY FINAL INSPOECTION. SMOKE DETECTOR SHALL BE PLACED 314.3 (1)IN SLEEPING ROOM STRAPS: SUPPORT OF PIPING EVERY 4 19 REQUIRED FOR SMOOTH WALL PIPING OR EVERY 6 19 FOR STEEL PIPE. FBCG 2424 PAN SIZE M1411.3.1 (1) AUXILIARY AND SECONDARY DRAIN SYSTEMSMUST NOT BE LESS THAN 3 1D LONGER AND WIDER
ALL ROUGH 08/17/2016 Disapproved -FEE REQUIRED LMILLER
Note: approved by error earlier today, (trying to result a different inspection and accidentally resulted it on this permit) INSPECTECTION SDTOPPED, TO MANY DEFICIENT ITEMS (INCOMPLETE INSPECTION) (PARTIAL LIST FOLLOWS) NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE. CHECK ALL, FIREBLOCKING R302.11 1-6 PLUMBINF CHASE WALL (AT BOTTOM OF STAIRS) GAS FIRE PLACE NOT INSTALLED AND FRAMING FOR GAS FIRE PLACE NOT COMPLETE
ALL ROUGH 08/16/2016 CANCELLED BY APPLICANT AIRS WEB
ELECTRIC-TUG 08/16/2016 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED TUG 3:10
GRAVITY SEWER TEST 08/15/2016 APPROVED LMILLER
Note: THIS IS A REINSPECTION
GRAVITY SEWER TEST 08/12/2016 CANCELLED BY APPLICANT AIRS WEB
Note: THIS IS A REINSPECTION
GRAVITY SEWER TEST 08/10/2016 CANCELLED BY APPLICANT CMINI
U - SEWER TIE IN 08/10/2016 APPROVED MBACON
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/29/2016 APPROVED LMILLER
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/28/2016 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION TIGHTEN LOOSE BOLTS/NUTS ON WALL TO WALL, AND BOTTOM PLATE CONECTIONS (CHECK ALL), PROVIDE DETAILS FOR CONTINUOUSE LOAD PATH AT WALL NEAR TOP OF STAIRS (MARKED WITH GREEN PAINT)
WALL SHEATHING 07/28/2016 APPROVED LMILLER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/18/2016 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION, INCOMPLETE INSPECCTION, TO MANY DEFICIENT ITEMS TO CONTINUE INSPECTION, CONTINUOUS LOAD PATH 26 R301,2.1 VALLY NOT TIED TO STRUCTURAL MEMBERS BENEATH, POSTS AT REAR PORCH UP STAIRS NEEDS CONTINUOUSE LOAD PATH S, WALL AT TOP OF STAIRS NEEDS CONTINUOUSE LOAD PATH, (NEED REVISION WITH ATTACHEMENT DETAILS), OVER FRAMING NOT COMPLETED TO DETAIL (SEE DETAIL ON PLANS), CONTINUOUSE LOAD PATH NOT CARRIED THROUGH TO FLOOR TRUSSES AND OR WALLS ABOVE gIRDERS NOT STRAPPED AS REQUIRED), ETC. ETC. ETC.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/15/2016 Disapproved -FEE REQUIRED LMILLER
Note: NOT READY, ROOF NOT COMPLETE, (STILL WORKING) COMPLETE WORK AND RE-CALL INSPECTION.
TIE BEAM / LINTEL 06/24/2016 APPROVED LMILLER
ELEV CERT-FOUNDATION APPROVAL 06/23/2016 APPROVED DBEVAN
FOUND SURVEY APPROVED (OFFICE) 06/21/2016 APPROVED DREWIS
MONOLITHIC SLAB 06/09/2016 APPROVED LMILLER
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 06/07/2016 Disapproved - NO FEE DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 6/7/2016 1:55:23 PM WHEN DIGGING FAILED FOOTER TO PROPER DEPTH HOUSE WATER SERVICE PIPE IS EXPOSED. RE-ROUTE PIPE TO AVOID CONCRETE LOAD OR LOCATE PIPE 12 INCHES UNDER FOOTING.SERVICE PIPE MUST BE PROTECTED.FBC-PLUMBING
MONOLITHIC SLAB 06/06/2016 Disapproved -FEE REQUIRED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 6/6/2016 2:13:49 PM 3FT X 3FT FOOTER LEFT FRONT GARAGE MUST BE 16IN DEEP PER PLAN
MONOLITHIC SLAB 06/02/2016 CANCELLED BY APPLICANT DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 05/25/2016 APPROVED - AS NOTED LMILLER
Note: THIS IS A REINSPECTION Inspection Resulted at 5/25/2016 1:51:00 PM OBTAIN REVISION FOR ADDED HOSE BIBS BY ALL ROUGH
PLUMBING 1ST ROUGH UNDERGROUND 05/24/2016 Disapproved -FEE REQUIRED LMILLER
Note: Inspection Resulted at 5/24/2016 11:32:24 AM DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL

Review History

Department Status Date In Date Out
PLFM COMPLETE 01/11/2017 01/11/2017
Note: No comments.
PLFM HOLD 01/03/2017 01/04/2017
Note: As noted in comments dated 12-29-16: Within Section D, the Signature and associated date of the certifying professional is required. Please sign, date and submit a correction resubmittal. The previously submitted EC did not include a signature within the referenced section. Note that the elevation certificate form provided is no longer valid and expired on December 31, 2016. For resubmittal, the signing and sealing professional shall utilize the elevation certificate form OMB No. 1660-0008 with expiration: November 30, 2016. A community is not allowed to take the July 31, 2015 after December 31, 2016.
PLFM HOLD 12/28/2016 12/29/2016
Note: Within Section D of the provided elevation certificate, the signature and associated date of the certifying professional is required. Please sign, date and submit a correction resubmittal. Informational: In future submittals of elevation certificates, the signing and sealing professional shall utilize the elevation certificate form OMB No. 1660-0008 with expiration: November 30, 2016. A community is not allowed to take the July 31, 2015 after December 31, 2016.
SW1 COMPLETE 12/27/2016 12/29/2016
Note: Released By: JHINDMAN final s
MECH COMPLETE 11/01/2016 11/02/2016
ELEC COMPLETE 11/01/2016 11/02/2016
MECH HOLD 08/02/2016 08/03/2016
Note: Repeat comment. Revision: revised energy calculations. Provide revised plans/details and insulation type information affected by the change from vented to unvented attic per FBC 5th ed. 107.2.1/ R806.5. F.Reodica-386-986-4734. Notes: 1. Affected plans/details are sheets 6 and 8 of 9 where insulation at the attic and its application were changed. 2. Insulation type refers to specifications of insulation to be used.
MECH HOLD 07/27/2016 07/28/2016
Note: Revision: revised energy calculations. Provide revised plans/details and insulation type information affected by the change from vented to unvented attic per FBC 5th ed. 107.2.1/ R806.5. F.Reodica-386-986-4734.
PLFM COMPLETE 06/23/2016 06/23/2016
SW1 COMPLETE 06/21/2016 06/21/2016
Note: Released By: DREWIS FOUNDATION S
ELEC COMPLETE 05/06/2016 05/06/2016
PLFM COMPLETE 04/28/2016 04/29/2016
ELEC HOLD 04/28/2016 04/29/2016
Note: Per 4/22 hold, please provide the code to be referenced. -DC. Rewis 986-4736
MECH COMPLETE 04/28/2016 05/03/2016
BLD COMPLETE 04/19/2016 04/21/2016
ELEC HOLD 04/19/2016 04/20/2016
Note: Please provide: The current code to be refrenced. A weather proof GFCI on front porch, NEC 2011 210.52 E3. Disconnect for condensing unit, NEC 2011 440.14. -DC. Rewis 986-4736
ENGIN1 COMPLETE 04/19/2016 04/20/2016
MECH HOLD 04/19/2016 04/21/2016
Note: 1. Provide hvac plan with signature and license number of hvac contractor per FBC 5th ed. 107.2.1. 2. Verify the pipe sizes serving tankless water heater and downstream of 2nd stage regulator per FBCFG 5th ed. T-402.4(32). F.N.Reodica-386-986-4734.
PLUM COMPLETE 04/19/2016 04/21/2016
SW1 COMPLETE 04/19/2016 04/20/2016
UD1 COMPLETE 04/19/2016 04/21/2016
ZON COMPLETE 04/19/2016 04/21/2016
PLFM HOLD 04/19/2016 04/20/2016
Note: 1. According to the provided site plan, a 250-gallon propane tank is proposed to be installed underground. The tank shall be installed 1-foot above base flood elevation [10.02.06, LDC] and anchored to ensure that the tank will not be displaced due to buoyancy forces and result in flood hazards. Provide calculations and detail of how the tank will be anchored to minimize threat of buoyancy hazards. 2. For Section B9 of the Elevation Certificate, the BFE elevation has to be indicated in tenths (for example 6.0’). Informational: Please note that an additional elevation certificate will be required at two (2) future stages: 1) Building Under Construction (at foundation) and 2) Finished Construction (final)
URB COMPLETE 04/19/2016 04/19/2016

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 01/09/2017
REINSPECTION FEE ¤40.00 01/05/2017
REINSPECTION FEE ¤40.00 01/05/2017
REVISION ¤40.00 12/27/2016
REVISION ¤40.00 12/27/2016
REINSPECTION FEE ¤40.00 12/27/2016
REINSPECTION FEE ¤40.00 12/27/2016
REINSPECTION FEE ¤40.00 12/27/2016
REINSPECTION FEE ¤40.00 12/27/2016
REINSPECTION FEE ¤40.00 12/27/2016
REINSPECTION FEE ¤40.00 12/27/2016
REINSPECTION FEE ¤40.00 12/27/2016
REINSPECTION FEE ¤40.00 12/27/2016
REINSPECTION FEE ¤40.00 12/27/2016
ADMIN FEE ¤20.00 05/06/2016
ELECTRIC FEE ¤298.80 05/06/2016
3% FIRE IMPACT FEE CREDIT (¤6.38) 05/06/2016
IMPACT FEE FIRE NONRESIDENTIAL ¤212.80 05/06/2016
IMPACT FEE PARKS ¤849.24 05/06/2016
IMPACT FEE SCHOOL ¤3,600.00 05/06/2016
IMPACT FEE TRANSPORTATION ¤3,124.67 05/06/2016
MECHANICAL FEE ¤298.80 05/06/2016
3% PARKS IMPACT FEE CREDIT (¤25.48) 05/06/2016
PLAN CHECK FEE ¤159.20 05/06/2016
PLUMBING FEE ¤298.80 05/06/2016
SITE PLAN 20 ¤20.00 05/06/2016
SURCHARGE FS 533.721 ¤28.81 05/06/2016
SURCHARGE - FS 468.631 ¤28.81 05/06/2016
STORM WATER PERMIT FEES ¤80.00 05/06/2016
3% TRANS IMPACT FEE CREDIT (¤93.74) 05/06/2016
NEW RESIDENTIAL INSPECTIONS ¤796.00 05/06/2016
Fees Total Due: ¤0.00 Total Paid: ¤10,250.33