Permit #2016040655
Permit Details
Status: COED
| Parcel Id: 15-11-31-2832-00000-0940 |
| CONDITIONED SPACE: 2828 sqft |
| GARAGE: 486 sqft |
| OPENED PORCH (WITH ROOF) : 228 sqft |
| OPENED PORCH (WITH ROOF) : 156 sqft |
| OPENED PORCH (WITH ROOF) : 109 sqft |
| Total Square Footage: 3807 sqft |
| Block: 00000 |
| Subdivision: 1072 - FRONT STREET @ GRAND HAVEN PHASE 2 |
| Job Phone: 386-947-4481 |
| Location Address: 88 FRONT ST |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/06/2016 |
| NOC: RECORDED |
| Applicant name: ERIC CHRISTOPHER OLSEN |
| Owner: MARK A LEO & KATHY M REICHARD-ELLAVSKY |
|
Address 88 FRONT ST PALM COAST, FL 32137 |
| Lot: 0940 |
| Contracted Stated Job Value: ¤397,964.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
OLSEN CUSTOM HOMES AND CONSULTING INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
CGC1508852 (Exp: 08/31/2026) | 386-947-4481 | (386)947-4484 |
Sub Contractors
BENJAMIN EDWARD SMITH
| Status | Location Address | State License Number | Phone |
| CANCEL |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
EC13004288 (Exp: 08/31/2016) | 386-265-2687 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32136 |
CAC048127 (Exp: 08/31/2018) | 386-445-5023 | 386-446-4614 |
JOHN BRADLEY WINFREY JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1685 S. CLARA AVE Deland, FL 32720 |
CFC054901 (Exp: 08/31/2026) | 386-734-0154 | 386-734-2751 |
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 01/13/2017 | FINAL APPROVED | JNICHOLS |
| Note: THIS IS A REINSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | 01/12/2017 | Disapproved - NO FEE | JNICHOLS |
| Note: the water meter pit has trash in it from the construction. looks like some one swept up a pile of trash and dumped it in the pit. the sewer clean out needs tobe raised to be flush with the grade and a flat cap needs to be installed. being in the mulch bed it will get covered and will not be able to locate if needed. | |||
| ROW FINAL | 01/09/2017 | Disapproved -FEE REQUIRED | RGROSS |
| Note: THIS IS A REINSPECTION. VACANT LOT NEEDS SEEDED. LOTS OF STRAW PLACED, BUT NO SEED. BARE EARTH NEAR BOTH PALM TREES NEED TO BE STABILIZED TO PREVENT SEDIMENT FROM WASHING OUT INTO THE CANAL. SEE PHOTO ATTACHED. | |||
| ROW FINAL | 01/09/2017 | APPROVED - AS NOTED | RGROSS |
| Note: THIS IS A REINSPECTION. CONTRACTOR PUT SOD ALONG SEAWALL AND ADDED SEED TO VACANT LOT. | |||
| BLD - BUILDING FINAL | 01/05/2017 | FINAL APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION | |||
| ROW FINAL | 01/05/2017 | CANCELLED BY APPLICANT | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| ROW FINAL | 01/03/2017 | Disapproved -FEE REQUIRED | RGROSS |
| Note: SOD THE FIRST 15 FT FROM THE MIAMI CURB ALONG THE ENTIRE ADJACENT PROPERTY. SEED AND STRAW THE ENTIRE ADJACENT LOT BEYOND THE 15 FT FROM MIAMI CURB. REGRADE AND SOD THE FIRST 5 FEET OF THE SEAWALL. POOL CO. WILL SOD THE REST WHEN POOL IS FINISHED. REMOVE DUMPSTER AND PAVERS FROM THE ADJACENT LOT. CLEAN SAND AND DEBRI FROM THE MIAMI GUTTER ON BOTH THE CONSTRUCTION AND ADJACENT LOT. ON SITE WITH CONTRACTOR. NOTE: POOL IS STILL UNDER CONSTRUCTION. POOL BUILDER WILL BE RESPOSIBLE FOR ANY FURTHER DAMAGE TO ADJACENT PROPERTY. | |||
| BLD - BUILDING FINAL | 01/03/2017 | Disapproved -FEE REQUIRED | LMILLER |
| Note: 1. NEED REVISION FOR ADDED ELECTRIC (CALLED FOR BY FINAL AND IS NOT ON SITE) 2. 3 inches AND SET LEVEL GROUND CLEARANCE, FOUNDATIONS AND SUPPORTS FBCM1403.2 EQUIPMENT AND APPLIANCES SHALL BE LEVEL AND FIRMLY SUPPORTED ON A CONCRETE PAD OR OTHER APPROVED MATERIAL EXTENDING NOT LESS THAN 3inches ABOVE THE ADJOINING GROUND 3. WORKING SPACE for electric equipment 26. E3405.2 36in. MINIMUM DEPTH AND 30in. MINIMUM WIDTH OR THE WIDTH OF THE EQUIPMENT (WICH EVER IS GREATER) 4. LEBELED GFCI OUTLET AT LEFT SIDE OF MASTER SINK (DIRECT SHORT) 5. HOT AND COLD WATER LOOPED (MUST REMOVE LOOP SO WE CAN CHECK HOT WATER PLACEMENT AT SINKS 6. PAN SIZE M1411.3.1 (1) AUXILIARY AND SECONDARY DRAIN SYSTEMSMUST NOT BE LESS THAN 3 1D LONGER AND WIDER 7.GARAGE DOOR SELF-CLOSING DEVICES R302.5.1 DOORS MUST BE EQUIPED WITH SELF-CLOSING DEVICE | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | 12/29/2016 | APPROVED | CTROHA |
| Note: THIS IS A REINSPECTION WORK COMPLETE | |||
| FINAL SURVEY (OFFICE USE ONLY) | 12/29/2016 | APPROVED | JHINDMAN |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 11/16/2016 | Disapproved -FEE REQUIRED | CTROHA |
| Note: MISSING DOCUMENTS: FINAL SURVEY TRIPPING HAZARD AT THE STREET PAVERS ARE HIGHER THAN MIAMI GUTTER ON RIGHT SIDE EDGE RESTRAINTS DO NOT MEET REQUIREMENTS SEE DRIVEWAY DETAIL | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 10/12/2016 | APPROVED - AS NOTED | RGROSS |
| Note: THIS IS A REINSPECTION. APRON FLARES MUST BE A MINIMUM OF 36 INCHES FOR THE FINAL. | |||
| ELECTRIC - EARLY POWER | 10/03/2016 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 3:17 | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 09/29/2016 | Disapproved -FEE REQUIRED | RGROSS |
| Note: SITE NOT READY FOR INSPECTION. NO SUB-BASE, NO FORM BOARDS IN PLACE, NO PAVERS ON SITE. PHOTO'S ON FILE. | |||
| INSULATION | 08/25/2016 | APPROVED | CMINI |
| ALL ROUGH | 08/23/2016 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION. need to support SER cable every 4-1/2' in attic, garage outlet not complete, open end. disconnect for AHU not complete, open wiring. missing 10' head. check on isulation | |||
| LATH/BRICK/ WATER BARRIER | 08/19/2016 | APPROVED | DROCKWELL |
| ALL ROUGH | 08/18/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: THIS IS A REINSPECTION 10ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.4, (EMPTY) NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE. (THROUGHOUT) GAS TIGHT FBC P3003.1 JOINTS AND CONNECTIONS IN THE DWV SYSTEM SHALL BE GAS TIGHT AND WATER TIGHT FOR THE INTENDED USE OR PRESSURE REQUIRED BY TEST (VTR NOT CONNECTED) CANNOT PLACE USED MATERIAL IN NEW CONSTRUCTION (LIVING ROOM CEILING PAINT COVERED LIGHT BOXES) NEED REVISION FOR ADDED ELECTRIC BY FINAL INSPOECTION. SMOKE DETECTOR SHALL BE PLACED 314.3 (1)IN SLEEPING ROOM STRAPS: SUPPORT OF PIPING EVERY 4 19 REQUIRED FOR SMOOTH WALL PIPING OR EVERY 6 19 FOR STEEL PIPE. FBCG 2424 PAN SIZE M1411.3.1 (1) AUXILIARY AND SECONDARY DRAIN SYSTEMSMUST NOT BE LESS THAN 3 1D LONGER AND WIDER | |||
| ALL ROUGH | 08/17/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: approved by error earlier today, (trying to result a different inspection and accidentally resulted it on this permit) INSPECTECTION SDTOPPED, TO MANY DEFICIENT ITEMS (INCOMPLETE INSPECTION) (PARTIAL LIST FOLLOWS) NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE. CHECK ALL, FIREBLOCKING R302.11 1-6 PLUMBINF CHASE WALL (AT BOTTOM OF STAIRS) GAS FIRE PLACE NOT INSTALLED AND FRAMING FOR GAS FIRE PLACE NOT COMPLETE | |||
| ALL ROUGH | 08/16/2016 | CANCELLED BY APPLICANT | AIRS WEB |
| ELECTRIC-TUG | 08/16/2016 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO DELL FPL RELEASED TUG 3:10 | |||
| GRAVITY SEWER TEST | 08/15/2016 | APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION | |||
| GRAVITY SEWER TEST | 08/12/2016 | CANCELLED BY APPLICANT | AIRS WEB |
| Note: THIS IS A REINSPECTION | |||
| GRAVITY SEWER TEST | 08/10/2016 | CANCELLED BY APPLICANT | CMINI |
| U - SEWER TIE IN | 08/10/2016 | APPROVED | MBACON |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/29/2016 | APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/28/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: THIS IS A REINSPECTION TIGHTEN LOOSE BOLTS/NUTS ON WALL TO WALL, AND BOTTOM PLATE CONECTIONS (CHECK ALL), PROVIDE DETAILS FOR CONTINUOUSE LOAD PATH AT WALL NEAR TOP OF STAIRS (MARKED WITH GREEN PAINT) | |||
| WALL SHEATHING | 07/28/2016 | APPROVED | LMILLER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/18/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: THIS IS A REINSPECTION, INCOMPLETE INSPECCTION, TO MANY DEFICIENT ITEMS TO CONTINUE INSPECTION, CONTINUOUS LOAD PATH 26 R301,2.1 VALLY NOT TIED TO STRUCTURAL MEMBERS BENEATH, POSTS AT REAR PORCH UP STAIRS NEEDS CONTINUOUSE LOAD PATH S, WALL AT TOP OF STAIRS NEEDS CONTINUOUSE LOAD PATH, (NEED REVISION WITH ATTACHEMENT DETAILS), OVER FRAMING NOT COMPLETED TO DETAIL (SEE DETAIL ON PLANS), CONTINUOUSE LOAD PATH NOT CARRIED THROUGH TO FLOOR TRUSSES AND OR WALLS ABOVE gIRDERS NOT STRAPPED AS REQUIRED), ETC. ETC. ETC. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/15/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: NOT READY, ROOF NOT COMPLETE, (STILL WORKING) COMPLETE WORK AND RE-CALL INSPECTION. | |||
| TIE BEAM / LINTEL | 06/24/2016 | APPROVED | LMILLER |
| ELEV CERT-FOUNDATION APPROVAL | 06/23/2016 | APPROVED | DBEVAN |
| FOUND SURVEY APPROVED (OFFICE) | 06/21/2016 | APPROVED | DREWIS |
| MONOLITHIC SLAB | 06/09/2016 | APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB | 06/07/2016 | Disapproved - NO FEE | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/7/2016 1:55:23 PM WHEN DIGGING FAILED FOOTER TO PROPER DEPTH HOUSE WATER SERVICE PIPE IS EXPOSED. RE-ROUTE PIPE TO AVOID CONCRETE LOAD OR LOCATE PIPE 12 INCHES UNDER FOOTING.SERVICE PIPE MUST BE PROTECTED.FBC-PLUMBING | |||
| MONOLITHIC SLAB | 06/06/2016 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/6/2016 2:13:49 PM 3FT X 3FT FOOTER LEFT FRONT GARAGE MUST BE 16IN DEEP PER PLAN | |||
| MONOLITHIC SLAB | 06/02/2016 | CANCELLED BY APPLICANT | DROCKWELL |
| PLUMBING 1ST ROUGH UNDERGROUND | 05/25/2016 | APPROVED - AS NOTED | LMILLER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/25/2016 1:51:00 PM OBTAIN REVISION FOR ADDED HOSE BIBS BY ALL ROUGH | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 05/24/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: Inspection Resulted at 5/24/2016 11:32:24 AM DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL |
Review History
| Department | Status | Date In | Date Out |
| PLFM | COMPLETE | 01/11/2017 | 01/11/2017 |
| Note: No comments. | |||
| PLFM | HOLD | 01/03/2017 | 01/04/2017 |
| Note: As noted in comments dated 12-29-16: Within Section D, the Signature and associated date of the certifying professional is required. Please sign, date and submit a correction resubmittal. The previously submitted EC did not include a signature within the referenced section. Note that the elevation certificate form provided is no longer valid and expired on December 31, 2016. For resubmittal, the signing and sealing professional shall utilize the elevation certificate form OMB No. 1660-0008 with expiration: November 30, 2016. A community is not allowed to take the July 31, 2015 after December 31, 2016. | |||
| PLFM | HOLD | 12/28/2016 | 12/29/2016 |
| Note: Within Section D of the provided elevation certificate, the signature and associated date of the certifying professional is required. Please sign, date and submit a correction resubmittal. Informational: In future submittals of elevation certificates, the signing and sealing professional shall utilize the elevation certificate form OMB No. 1660-0008 with expiration: November 30, 2016. A community is not allowed to take the July 31, 2015 after December 31, 2016. | |||
| SW1 | COMPLETE | 12/27/2016 | 12/29/2016 |
| Note: Released By: JHINDMAN final s | |||
| MECH | COMPLETE | 11/01/2016 | 11/02/2016 |
| ELEC | COMPLETE | 11/01/2016 | 11/02/2016 |
| MECH | HOLD | 08/02/2016 | 08/03/2016 |
| Note: Repeat comment. Revision: revised energy calculations. Provide revised plans/details and insulation type information affected by the change from vented to unvented attic per FBC 5th ed. 107.2.1/ R806.5. F.Reodica-386-986-4734. Notes: 1. Affected plans/details are sheets 6 and 8 of 9 where insulation at the attic and its application were changed. 2. Insulation type refers to specifications of insulation to be used. | |||
| MECH | HOLD | 07/27/2016 | 07/28/2016 |
| Note: Revision: revised energy calculations. Provide revised plans/details and insulation type information affected by the change from vented to unvented attic per FBC 5th ed. 107.2.1/ R806.5. F.Reodica-386-986-4734. | |||
| PLFM | COMPLETE | 06/23/2016 | 06/23/2016 |
| SW1 | COMPLETE | 06/21/2016 | 06/21/2016 |
| Note: Released By: DREWIS FOUNDATION S | |||
| ELEC | COMPLETE | 05/06/2016 | 05/06/2016 |
| PLFM | COMPLETE | 04/28/2016 | 04/29/2016 |
| ELEC | HOLD | 04/28/2016 | 04/29/2016 |
| Note: Per 4/22 hold, please provide the code to be referenced. -DC. Rewis 986-4736 | |||
| MECH | COMPLETE | 04/28/2016 | 05/03/2016 |
| BLD | COMPLETE | 04/19/2016 | 04/21/2016 |
| ELEC | HOLD | 04/19/2016 | 04/20/2016 |
| Note: Please provide: The current code to be refrenced. A weather proof GFCI on front porch, NEC 2011 210.52 E3. Disconnect for condensing unit, NEC 2011 440.14. -DC. Rewis 986-4736 | |||
| ENGIN1 | COMPLETE | 04/19/2016 | 04/20/2016 |
| MECH | HOLD | 04/19/2016 | 04/21/2016 |
| Note: 1. Provide hvac plan with signature and license number of hvac contractor per FBC 5th ed. 107.2.1. 2. Verify the pipe sizes serving tankless water heater and downstream of 2nd stage regulator per FBCFG 5th ed. T-402.4(32). F.N.Reodica-386-986-4734. | |||
| PLUM | COMPLETE | 04/19/2016 | 04/21/2016 |
| SW1 | COMPLETE | 04/19/2016 | 04/20/2016 |
| UD1 | COMPLETE | 04/19/2016 | 04/21/2016 |
| ZON | COMPLETE | 04/19/2016 | 04/21/2016 |
| PLFM | HOLD | 04/19/2016 | 04/20/2016 |
| Note: 1. According to the provided site plan, a 250-gallon propane tank is proposed to be installed underground. The tank shall be installed 1-foot above base flood elevation [10.02.06, LDC] and anchored to ensure that the tank will not be displaced due to buoyancy forces and result in flood hazards. Provide calculations and detail of how the tank will be anchored to minimize threat of buoyancy hazards. 2. For Section B9 of the Elevation Certificate, the BFE elevation has to be indicated in tenths (for example 6.0’). Informational: Please note that an additional elevation certificate will be required at two (2) future stages: 1) Building Under Construction (at foundation) and 2) Finished Construction (final) | |||
| URB | COMPLETE | 04/19/2016 | 04/19/2016 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 01/09/2017 |
| REINSPECTION FEE | ¤40.00 | 01/05/2017 |
| REINSPECTION FEE | ¤40.00 | 01/05/2017 |
| REVISION | ¤40.00 | 12/27/2016 |
| REVISION | ¤40.00 | 12/27/2016 |
| REINSPECTION FEE | ¤40.00 | 12/27/2016 |
| REINSPECTION FEE | ¤40.00 | 12/27/2016 |
| REINSPECTION FEE | ¤40.00 | 12/27/2016 |
| REINSPECTION FEE | ¤40.00 | 12/27/2016 |
| REINSPECTION FEE | ¤40.00 | 12/27/2016 |
| REINSPECTION FEE | ¤40.00 | 12/27/2016 |
| REINSPECTION FEE | ¤40.00 | 12/27/2016 |
| REINSPECTION FEE | ¤40.00 | 12/27/2016 |
| REINSPECTION FEE | ¤40.00 | 12/27/2016 |
| ADMIN FEE | ¤20.00 | 05/06/2016 |
| ELECTRIC FEE | ¤298.80 | 05/06/2016 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.38) | 05/06/2016 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤212.80 | 05/06/2016 |
| IMPACT FEE PARKS | ¤849.24 | 05/06/2016 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 05/06/2016 |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | 05/06/2016 |
| MECHANICAL FEE | ¤298.80 | 05/06/2016 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 05/06/2016 |
| PLAN CHECK FEE | ¤159.20 | 05/06/2016 |
| PLUMBING FEE | ¤298.80 | 05/06/2016 |
| SITE PLAN 20 | ¤20.00 | 05/06/2016 |
| SURCHARGE FS 533.721 | ¤28.81 | 05/06/2016 |
| SURCHARGE - FS 468.631 | ¤28.81 | 05/06/2016 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/06/2016 |
| 3% TRANS IMPACT FEE CREDIT | (¤93.74) | 05/06/2016 |
| NEW RESIDENTIAL INSPECTIONS | ¤796.00 | 05/06/2016 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,250.33 |