Permit #2016040730

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7034-00900-0090
SCREEN PORCH (SOLID ROOF) : 448 sqft
Total Square Footage: 448 sqft
Block: 00900
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 386-503-0906
Location Address: 27 ETHAN ALLEN DR
Type: BA - BUILDING ADDITION
Issue Date: 05/10/2016
NOC: RECORDED
Applicant name: ANTHONY FALLONE
Owner: RAMSEY, CAROL & AUBREY BERNARD

Address

27 ETHAN ALLEN DRIVE

PALM COAST, FL 32164

Lot: 0090
Contracted Stated Job Value: ¤22,000.00
Job Description: 32' X 14' SUN ROOM ADDITION W/ALUMINUM INSULATED ROOF
Type: CN

Contractor

FONTANA CONSTRUCTION, INC.
Status Location Address State License Number Phone Fax
CANCEL

P.O. BOX 351222

PALM COAST, FL 32137

CBC1250596 (Exp: 08/31/2022) 386-503-0906 (386)986-1305

Sub Contractors

RICHARD R EDWARDS
Status Location Address State License Number Phone
CANCEL

P. O. Box 1637

Bunnell, FL 32110

ER0011603 (Exp: 08/31/2022) (386) 437-1537
FRANK E SEVERINO
Status Location Address State License Number Phone Fax
ACTIVE

1360 N NOVA RD

DAYTONA BEACH, FL 32117

CBC060543 (Exp: 08/31/2026) 386-253-1943 386-238-0139

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 01/11/2017 FINAL APPROVED DSPENCER
BLD - BUILDING FINAL 08/16/2016 FINAL APPROVED DROCKWELL
Note: 2x2x1/8 angle roof hold-down not installes per plan.See section detail
BLD - BUILDING FINAL 08/09/2016 Disapproved -FEE REQUIRED LMILLER
Note: INCOMPLETE INSPECTION (ALL PAPERWORK IS SOAKED FROM WEATHER), NEED NEW PAPERWORK SO INSPECTION CAN BEE COMPLETED. ALSO APPROVED FINAL SURVEY MUST BE ONSITE AT TIME OF FINAL. EXTERIOR DOOR LIGHTS 26. EACH EXTERIOR DOOR SHALL HAVE A LIGHT AND SWITCH R 3903.3 (LIGHT BOX IS OPEN TO THE ELIMENTS AND LIGHT HAS NOT BEEN INSTALLED). GFCI 19S NEEDED, 210.8-A, ALL 120 VOLT SINGLE PHASE 15 AND 20 AMP RECEPTICLES INSTALLED IN LOCATIONS SPECIFIED IN 1 TROUGH 8 SHALL HAVE GFCI PROTECTION. (WITHIN 5ft OF POOL/HOT-TUB) METAL WINDOWS NEEDS TO BE BONDED .WITHIN 5 19 OF POOL OR SPAS INSIDE WALL.. NEC. 680.26 (7)
FINAL SURVEY (OFFICE USE ONLY) 08/08/2016 APPROVED FREODICA
Note: Final survey also shows on foundation survey.
ALL ROUGH 07/01/2016 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
INSULATION 07/01/2016 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 06/24/2016 APPROVED LMILLER
INSULATION 06/22/2016 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 6/22/2016 11:06:53 AM ALL ROUGH MUST FIRST BE APPROVED.REVISE PLAN TO SHOW DELETED 240 OUTLET AND CHANGED TO 110 FOR A/C
FRAMING 06/20/2016 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ALL ROUGH 06/20/2016 Disapproved - NO FEE DROCKWELL
Note: Inspection Resulted at 6/20/2016 11:23:54 AM PROVIDE WIRING FOR A/C UNIT AS PER PLAN
FOUND SURVEY APPROVED (OFFICE) 06/16/2016 APPROVED JHINDMAN
FRAMING 06/14/2016 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 6/14/2016 9:34:46 AM PLANS CALL FOR A 2X2 CONTINUOS ANGLE ANCHORING ROOF TO FRAMING AROUND ENTIRE PERIMETER
LATH/BRICK/ WATER BARRIER 05/27/2016 CANCELLED BY INSPECTOR DROCKWELL
Note: Inspection Resulted at 5/27/2016 10:07:59 AM NO INSPECTION AT THIS ADDRESS TODAY
MONOLITHIC SLAB 05/24/2016 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
ELEC COMPLETE 06/30/2016 07/05/2016
BLD COMPLETE 06/30/2016 06/30/2016
BLD HOLD 06/23/2016 06/23/2016
Note: 1. Provide a signed and sealed drawing by the engineer of record for the structural change. You cannot use the AAF as this structure was designed by him. 5th ed. FBC 107.1 and state statute 471.003. J. Hindman 986-3784.
ELEC COMPLETE 06/23/2016 06/24/2016
MECH COMPLETE 06/23/2016 06/23/2016
Note: Revision: N/A
SW1 COMPLETE 06/16/2016 06/16/2016
Note: Released By: JHINDMAN foundation s
MECH COMPLETE 05/06/2016 05/09/2016
ELEC COMPLETE 04/28/2016 04/29/2016
BLD COMPLETE 04/28/2016 05/02/2016
MECH HOLD 04/28/2016 05/03/2016
Note: Previous comment shall be addressed. Provide energy calculations, hvac contractor and manufacturer specification of hvac units to be installed per FBCEC 5th ed. R402/R405/FS 489.
MECH HOLD 04/21/2016 04/26/2016
Note: Provide energy calculations, hvac contractor and manufacturer specification of hvac units to be installed per FBCEC 5th ed. R402/R405/FS 489.
BLD HOLD 04/20/2016 04/25/2016
Note: 1. Provide the sunroom category type per the 5th edition of the Florida Building Code Residential 301.2.1.1.2.2 This is not the Risk Category that is shown on the plans. J. Hindman 986-3784..
SW1 COMPLETE 04/20/2016 04/21/2016
ZON COMPLETE 04/20/2016 04/21/2016
ELEC HOLD 04/20/2016 04/21/2016
Note: Please provide additional receptacles per NEC 2011 210.52. -DC. Rewis 986-4736

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 01/10/2017
REINSPECTION FEE ¤40.00 08/15/2016
REINSPECTION FEE ¤40.00 08/08/2016
REINSPECTION FEE ¤40.00 08/08/2016
REVISION ¤40.00 08/08/2016
REVISION ¤40.00 08/08/2016
SITE PLAN 20 ¤20.00 05/10/2016
SURCHARGE FS 533.721 ¤2.94 05/10/2016
SURCHARGE - FS 468.631 ¤2.94 05/10/2016
STORM WATER PERMIT FEES ¤80.00 05/10/2016
ADMIN FEE ¤20.00 05/10/2016
ELECTRIC FEE ¤73.20 05/10/2016
PLAN CHECK FEE ¤40.00 05/10/2016
REMODEL/ADDITION/ACCES INSPECT ¤40.00 05/10/2016
Fees Total Due: ¤0.00 Total Paid: ¤519.08