I want to search for...

Permit #2016040783

Permit Details

Status: COED

Parcel Id: 07-11-31-7035-01440-0060
CONDITIONED SPACE: 2427 sqft
GARAGE: 588 sqft
OPENED PORCH (WITH ROOF) : 187 sqft
OPENED PORCH (WITH ROOF) : 131 sqft
Total Square Footage: 3333 sqft
Block: 01440
Subdivision: -
Job Phone: 904-268-7730
Location Address: 33 BIG HORN DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/13/2016
NOC: RECORDED
Applicant name: KENNETH WAYNE CAMPBELL JR
Owner: MARONDA HOMES INC OF FLORIDA CORPORATION

Address

9700 PHILIPS HWY STE 102

PALM COAST, FL 32256

Lot: 0060
Contracted Stated Job Value: ¤140,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MARONDA HOMES INC. OF FLORIDA
Status Location Address State License Number Phone Fax
CANCEL

6800 SOUTHPOINT PKWAY SUITE 300

JACKSONVILLE, FL 32216

CBC058803 (Exp: 08/31/2018) 904-268-7730 904-268-7740

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
ROBERT G DELLO RUSSO
Status Location Address State License Number Phone Fax
DECEASED

531 CODISCO WAY

SANFORD, FL 32771

CAC032448 (Exp: 08/31/2022) (407)831-2665 (407)333-3853
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
DEBORAH MAXINE JACKSON
Status Location Address State License Number Phone Fax
CANCEL

9474 OLD PLANK RD

JACKSONVILLE , FL 32220

CCC1328530 (Exp: 08/31/2016) 904-435-7663 904-404-8406
JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313
JOSEPH JOHN VERRECHIO
Status Location Address Mailing Address State License Number Phone
CANCEL

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3D

PALM COAST, FL 32137

EC13004254 (Exp: 08/31/2016) 386-793-1811

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 11/28/2016 FINAL APPROVED JNICHOLS
Note: THIS IS A REINSPECTION
U -UTILITY RESIDENTIAL FINAL 11/23/2016 Disapproved - NO FEE DSPENCER
Note: the water meter must be flush to grade so it cannot be hit by mowing. pull back sod add fill tapering out not a mound and reset sod talked with builder
BLD - BUILDING FINAL 11/22/2016 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 11/21/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: THIS IS A REINSPECTIONneed cover outside outlet....master bath exhaust not working
BLD - BUILDING FINAL 11/18/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: rear porch oulet needs cover....50 amp breaker installed for AHU 45 max amp marked....top plug does not work at middle br. hot outlet....wxhaust vent mb toilet doe not work...arc sheild needed mirror ouletsMB
FINAL APRON (AFTER POUR/DRIVEWAY) 11/18/2016 APPROVED CTROHA
ROW FINAL 11/18/2016 APPROVED CTROHA
FINAL SURVEY (OFFICE USE ONLY) 11/17/2016 APPROVED FREODICA
ELECTRIC - EARLY POWER 11/09/2016 APPROVED - AS NOTED RMARTIN
Note: THIS IS A REINSPECTION SPOKE TO SUSAN FPL RELEASED EARLY POWER 11:35
ELECTRIC - EARLY POWER 11/08/2016 Disapproved -FEE REQUIRED RMARTIN
Note: ALL CONDUCTORS NEED TO BE SAFED OFF FOR INSPECTION, SWITCHES AND OUTLETS MISSING PLATES, FLOOR BOX NEEDS WIRE NUTS AND COVER, ALSO CIRCLED ON PLAN OUTLET MISSING OR COVERED IN FRONT BEDROOM WALL BEHIND DOOR
U - SEWER TIE IN 10/28/2016 APPROVED JNICHOLS
Note: THIS IS A REINSPECTION
U - SEWER TIE IN 10/21/2016 CANCELLED BY APPLICANT JNICHOLS
Note: pep tank is installed too high. can not tie the house service into the pep tank with fall in the pipe.
PRE-APRON (PRE-POUR/DRIVEWAY) 10/21/2016 APPROVED RGROSS
Note: READY TO POUR
LATH/BRICK/ WATER BARRIER 09/12/2016 APPROVED JCOLASANTI
INSULATION 09/09/2016 APPROVED JCOLASANTI
ALL ROUGH 09/07/2016 APPROVED - AS NOTED JCOLASANTI
Note: THIS IS A REINSPECTION NEED TO PHASE OUT HOT CONDUCTORS IN PANEL.210.5(C) (white conducter) will check at insulation)
ALL ROUGH 09/02/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: NEED TO SEAL EXHAUST BATH DUCT AT ROOF WITH MASTIC..FBC.. M1601.4.1.7. (front guest bath not sealed properly)....NEED TO PHASE OUT HOT CONDUCTORS IN PANEL.210.5(C .....FBC.M1502.4.2. PASSIVE RETURNS NOT INSTALLED front guest bedroom.....need to hold presure on water line.
ROOF VALLEY & METAL 08/23/2016 APPROVED JCOLASANTI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/22/2016 APPROVED JCOLASANTI
TIE BEAM / LINTEL 08/04/2016 APPROVED CMINI
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 08/03/2016 CANCELLED BY APPLICANT JCOLASANTI
MONOLITHIC SLAB 07/28/2016 APPROVED JCOLASANTI
Note: PER CONTRACTOR
PLUMBING 1ST ROUGH UNDERGROUND 07/22/2016 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 07/18/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: THIS IS A REINSPECTION The annular SPACE between thwe outside of a pipe anth the inside of a pipe sleeve shall be sealed with caulking material or foam sealant or closed whith a gasketing system FBC P2606.1
FOUND SURVEY APPROVED (OFFICE) 07/01/2016 APPROVED DREWIS
PLUMBING 1ST ROUGH UNDERGROUND 06/28/2016 CANCELLED BY APPLICANT JCOLASANTI
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 06/27/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: THIS IS A REINSPECTION Inspection Resulted at 6/27/2016 2:30:18 PM NEED REVISION ON HOW TO REPAIR FOOTING NOW THAT FOOTING HAS BEEN ALTERED AND REBAR CUT. FOOTING NO LONGER MEETS PLAN. FOAM SLEAVE AT FRONT ENTRANCE.
GRAVITY SEWER TEST 06/27/2016 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 06/24/2016 CANCELLED BY APPLICANT JCOLASANTI
PLUMBING 1ST ROUGH UNDERGROUND 06/23/2016 CANCELLED BY APPLICANT AIRS WEB
GRAVITY SEWER TEST 06/23/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 6/23/2016 12:13:43 PM NOT READY
GRAVITY SEWER TEST 06/22/2016 CANCELLED BY APPLICANT AIRS WEB
PLUMBING 1ST ROUGH UNDERGROUND 06/22/2016 CANCELLED BY APPLICANT AIRS WEB
STEM WALL FOUNDATION 06/03/2016 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
STEM WALL FOUNDATION 06/01/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 6/1/2016 11:01:04 AM NOT READY

Review History

Department Status Date In Date Out
SW1 COMPLETE 11/16/2016 11/17/2016
Note: Released By: FREODICA final s
BLD COMPLETE 07/13/2016 07/14/2016
SW1 COMPLETE 06/30/2016 07/01/2016
Note: Released By: DREWIS foundation s
ELEC COMPLETE 05/09/2016 05/09/2016
ZON COMPLETE 05/09/2016 05/10/2016
MECH COMPLETE 05/09/2016 05/10/2016
BLD COMPLETE 05/09/2016 05/10/2016
BLD HOLD 04/22/2016 04/26/2016
Note: Roofing Worksheet: 1. Underlayment of 15 # does not meet code per FBCR 5th ed. R905.2.7 (2). 2. Florida product approval number FL 10674-R1 for roof covering can not be found on code version 2014. Clarify per FBC 5th ed. 107.2.1. F.N.Reodica- 386-986-4734.
ELEC HOLD 04/22/2016 04/22/2016
Note: Electrical contractor on permit does not match the name on the plans. -DC. Rewis 986-4736
ENGIN1 COMPLETE 04/22/2016 05/09/2016
MECH HOLD 04/22/2016 04/26/2016
Note: Energy calculations and hvac plan do not match with floor plan. Coordinate for clarity pe FBC 5th ed. 107.2.1. F.N. Reodica - 386-986-4734.
PLUM COMPLETE 04/22/2016 04/26/2016
SW1 COMPLETE 04/22/2016 04/22/2016
UD1 COMPLETE 04/22/2016 04/26/2016
ZON HOLD 04/22/2016 04/26/2016
Note: Banding must be placed around ALL windows and doors visible from the right of way. Window shutters may substitute for banding where applicable.
URB COMPLETE 04/22/2016 04/22/2016

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 11/28/2016
REINSPECTION FEE ¤40.00 11/28/2016
REINSPECTION FEE ¤40.00 11/28/2016
REINSPECTION FEE ¤40.00 11/28/2016
REINSPECTION FEE ¤40.00 11/28/2016
REINSPECTION FEE ¤40.00 11/28/2016
REINSPECTION FEE ¤40.00 11/28/2016
REINSPECTION FEE ¤40.00 11/28/2016
REINSPECTION FEE ¤40.00 11/28/2016
REVISION ¤40.00 11/28/2016
SITE PLAN 20 ¤20.00 05/13/2016
SURCHARGE FS 533.721 ¤22.92 05/13/2016
SURCHARGE - FS 468.631 ¤22.92 05/13/2016
STORM WATER PERMIT FEES ¤80.00 05/13/2016
3% TRANS IMPACT FEE CREDIT (¤93.74) 05/13/2016
NEW RESIDENTIAL INSPECTIONS ¤612.00 05/13/2016
ADMIN FEE ¤20.00 05/13/2016
CONTRACTOR CHANGE ¤40.00 05/13/2016
ELECTRIC FEE ¤243.60 05/13/2016
3% FIRE IMPACT FEE CREDIT (¤6.38) 05/13/2016
IMPACT FEE FIRE NONRESIDENTIAL ¤212.80 05/13/2016
IMPACT FEE PARKS ¤849.24 05/13/2016
IMPACT FEE SCHOOL ¤3,600.00 05/13/2016
IMPACT FEE TRANSPORTATION ¤3,124.67 05/13/2016
MECHANICAL FEE ¤243.60 05/13/2016
3% PARKS IMPACT FEE CREDIT (¤25.48) 05/13/2016
PLAN CHECK FEE ¤122.40 05/13/2016
PLUMBING FEE ¤243.60 05/13/2016
Fees Total Due: ¤0.00 Total Paid: ¤9,732.15