Permit #2016040948

Permit Details

Status: COED

Parcel Id: 48-11-31-1700-00000-0170
CONDITIONED SPACE: 3155 sqft
GARAGE: 560 sqft
SCREEN PORCH (SOLID ROOF) : 378 sqft
OPENED PORCH (WITH ROOF) : 60 sqft
Total Square Footage: 4153 sqft
Block: 00000
Subdivision: 2086 - ESTATES AT GRAND HAVEN PHASE I
Job Phone: 386-947-4481
Location Address: 105 WILLOW OAK WAY
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/09/2016
NOC: RECORDED
Applicant name: ERIC CHRISTOPHER OLSEN
Owner: ROLLE, ROBERT P & SUSAN E

Address

171 BROOKHAVEN CT

PALM COAST, FL 32164

Lot: 0170
Contracted Stated Job Value: ¤400,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

OLSEN CUSTOM HOMES AND CONSULTING INC
Status Location Address State License Number Phone Fax
ACTIVE

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

CGC1508852 (Exp: 08/31/2026) 386-947-4481 (386)947-4484

Sub Contractors

BENJAMIN EDWARD SMITH
Status Location Address State License Number Phone
CANCEL

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

EC13004288 (Exp: 08/31/2016) 386-265-2687
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32136

CAC048127 (Exp: 08/31/2018) 386-445-5023 386-446-4614
JOHN BRADLEY WINFREY JR
Status Location Address State License Number Phone Fax
ACTIVE

1685 S. CLARA AVE

Deland, FL 32720

CFC054901 (Exp: 08/31/2026) 386-734-0154 386-734-2751
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 03/13/2017 FINAL APPROVED DSPENCER
Note: the utility department may still need to adjust the meters however i will not hold the final for that issue they can follow up on later. the 6" cleanout cap is not approved type must be flush slotted type. the one used iis now a 2" nut cap inverted upside down. After doing more research i found that the mfg has changed the style of the cap the old type is currently unavailable. i apoligize for the inconvience.
U -UTILITY RESIDENTIAL FINAL 03/10/2017 Disapproved -FEE REQUIRED DSPENCER
Note: THIS IS A REINSPECTION found no changes have been made to the original issues as noted below and the cleanout body on the 6" is not the correct size for the pipe and must be replaced with the correct size. some fill is needed to make the grade flush with the meter pit. utilities is looking into the meters to see if the relocation will be required. Failed inspection the reclaim meter is less than a foot from the drive and the potable less than 2 19. Notes added to inspection were. 1. the 4" sewer cleanout next the drive must be cut and capped below grade. 2. the 6" cleanout cap must be a flush slotted cap set at grade. not an inverted 2" nut cap 3. the reuse water meter and potable water meters cannot be closer than 4.5' to the drive way per city standards as noted on the building permit and the builder should have contacted and requested them both be moved by the utility department which is what needs to be done now. the decision for the meters is the Utility departments if any exceptions will be made.
U -UTILITY RESIDENTIAL FINAL 03/09/2017 Disapproved -FEE REQUIRED DSPENCER
Note: Utility department has been notified. Failed inspection the reclaim meter is less than a foot from the drive and the potable less than 2 19. 1. the 4" sewer cleanout next the drive must be cut and capped below grade. 2. the 6" cleanout cap must be a flush slotted cap set at grade. not an inverted 2" nut cap 3. the reuse water meter and potable water meters cannot be closer than 4.5' to the drive way per city standards as noted on the building permit and the builder should have contacted and requested them both be moved by the utility department which is what needs to be done now. the decision for the meters is the Utility departments if any exceptions will be made.
BLD - BUILDING FINAL 03/08/2017 FINAL APPROVED LMILLER
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 03/07/2017 Disapproved -FEE REQUIRED DROCKWELL
Note: Revision for kitchen not yet available
BLD - BUILDING FINAL 03/06/2017 Disapproved -FEE REQUIRED LMILLER
Note: 1. REVISION FOR KITCHEN COUNTER AND COUNTER ELECTRIC REQUESTED BY FINAL AT FIRST ALL-ROUGH INSPECTION STILL NEEDED. 2. WORKING SPACE for electric equipment 26. E3405.2 36in. MINIMUM DEPTH AND 30in. MINIMUM WIDTH OR THE WIDTH OF THE EQUIPMENT (WICH EVER IS GREATER) (BOTH CONDENSORS) 3. HOLES IN CEILING MUST BE SEALED: R302.11 (4) PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVEL (WITH APPROVED MATERIAL) (AT CONDUIT AND DUCTS)
FINAL APRON (AFTER POUR/DRIVEWAY) 03/03/2017 APPROVED GLALIMA
ROW FINAL 03/03/2017 APPROVED - AS NOTED GLALIMA
Note: IF THE RIGHT FRONT CORNER THAT IS LOW, BECOMES AN DRAINAGE ISSUE IT WILL BE UP TO THE BUILDER TO REPAIR. LEFT SIDE DRAINAGE WILL BE ADDRESSED AT POOL R.O.W / FINAL .
FINAL SURVEY (OFFICE USE ONLY) 03/02/2017 APPROVED FREODICA
Note: THIS IS A REINSPECTION Field verified by G. Lalima
FINAL APRON (AFTER POUR/DRIVEWAY) 03/01/2017 CANCELLED BY INSPECTOR CTROHA
Note: THIS IS A REINSPECTION REVIEWING FINAL SURVEY
FINAL APRON (AFTER POUR/DRIVEWAY) 02/16/2017 Disapproved -FEE REQUIRED GLALIMA
Note: NO APPROVED FINAL SURVEY , THE FINAL SURVEY MUST SHOW ALL SET BACKS AND EASEMENTS ON PROPERTY AS WELL AS ELEVATIONS EVERY 20' FEET . PROPERTY PINS NEED TO BE LOCATED AND IN PLACE . I HAVE MY LAST SITE MEET WITH HOME TOMORROW AT 10:00 TO GO OVER WHAT GRANHAVEN HAS ALL READY TOLD HIM. SOPKE WITH POOL BUILDER AND HE WILL DO FINAL GRADE. CAN NOT FINAL DRIVEWAY UNTIL THE FINAL SURVEY IS APPROVED AND ON SITE
FINAL SURVEY (OFFICE USE ONLY) 02/16/2017 Disapproved - NO FEE FREODICA
Note: 1. Drainage flow shall match with prposed plan. 2. Provide grading elevations at 20 foot intervals along the property line and at 10 foot offset to adjacent properties.. 3. Drainage flow to the ditch at left side of the house.is not allowed.
ELECTRIC - EARLY POWER 12/14/2016 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED EARLY POWER 3:05
PRE-APRON (PRE-POUR/DRIVEWAY) 12/12/2016 APPROVED CTROHA
Note: READY TO POUR
PRE-APRON (PRE-POUR/DRIVEWAY) 12/09/2016 Disapproved -FEE REQUIRED CTROHA
Note: THIS IS A REINSPECTION FLARES DO NOT MEET REQUIREMENTS SEE DETAIL SHEET
PRE-APRON (PRE-POUR/DRIVEWAY) 12/08/2016 CANCELLED BY APPLICANT GLALIMA
Note: BUILDER CALLED AND CANCELLED 9:03A:M
INSULATION 10/28/2016 APPROVED LMILLER
Note: THIS IS A REINSPECTION
INSULATION 10/25/2016 Disapproved -FEE REQUIRED LMILLER
Note: MUST HAVE ENERGY CALCS ON SITE FOR THIS INSPECTION
ALL ROUGH 10/21/2016 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION. bath duct off of fan, reconnect.. low voltage nail plates not complete. window in bathroom not screwed in.
LATH/BRICK/ WATER BARRIER 10/21/2016 APPROVED CMINI
Note: THIS IS A REINSPECTION
TRACK BOLT 10/17/2016 APPROVED CMINI
LATH/BRICK/ WATER BARRIER 10/17/2016 Disapproved -FEE REQUIRED CMINI
Note: not ready, front door area and wood exposed at mitered window
ALL ROUGH 10/05/2016 Disapproved -FEE REQUIRED LMILLER
Note: 1. NAIL PLATES ON LOW VOLTAGE THROUGHOUT AND AT KITCHEN COUNTER SINK HALF WALL NAIL PLATES ON ELECTRIC FBC E3802.1 2. MISSING ELECTRIC BOXES AND WIRING OUT OF WALL DUE TO MISSING DOOR BUCKS AND MISSING SLIDER FRAMING. 3. MISSING FRAMING (BOX OUT ABOVE ELECTRIC PANEL) 4. MULLION SHIMS, SHIM WINDOW MULLIONS IN ACCORDANCE WITH FBC 612.7.2.1 AND MANUFACTURER INSTALLATION SPECS (NO MORE THAN .25 inch GAP AND SHIMMED). OR PROVIDE SPECS FOR INSTALATION METHOD USED. 5. NAIL PLATES FOR PLUMBING AT TOP PLATES IN GARAGE AND WAGTER SUPPLY IN MASTER SHOWER AND BATH TUB NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE. 6.10ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1), 7. CALL IN SEPARATE INSPECTION FOR FIXED GLASS AND SLIDER FRAMING (TRACK INSPECTION) *. NEED REVISION BY FINAL FOR KITCHEN COUNTER (PLAN SHOWS MULTY LEVEL COUNTER, ELECTRIC IS INSTALLED FOR FLAT TOP) CORRECT ELECTRIC TO MATCH PLANS OR OBTAIN APPROVED REVISION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/29/2016 APPROVED LMILLER
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/08/2016 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION INCOMPLETE INSPECTION, NOT READY, ROOF SHEATHING PASSED, DOWN CELLS PASSED, NEED TO CHECK ALL BRACES, TIES, AND BEARING. (NOT COMPLETE, STILL WORKING).
ELECTRIC-TUG 09/08/2016 APPROVED - AS NOTED LMILLER
Note: TALKED TO SUSAN AT FPL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/07/2016 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 9/7/2016 1:54:03 PM NO PLANS ENGINEERING ON JOB,
TIE BEAM / LINTEL 08/18/2016 APPROVED LMILLER
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 08/17/2016 Disapproved -FEE REQUIRED LMILLER
Note: CLEARANCE FROM MASONRY R606.13.4 MINIMUM WALL REINFORCING STEEL COVERAGE NOT MET OVERBEND DOWEL BAR FBC R606.13.3 EXCEPTION 26.. WITH A VERTICAL CELL NOT MORE THAN 1 1D OF HORIZONTAL DISPLACEMENT TO 6 1D OF VERTICAL BAR LENGTH. (SEVERAL AREAS, CIRCLED ON FOUNDATION SHEET. OB- INDICATES OVER BEND, C- INDICATES CLEARANCE)
ELEV CERT-FOUNDATION APPROVAL 08/16/2016 APPROVED DBEVAN
GRAVITY SEWER TEST 08/11/2016 FINAL APPROVED CMINI
Note: THIS IS A REINSPECTION
U - SEWER TIE IN 08/11/2016 APPROVED JNICHOLS
Note: THIS IS A REINSPECTION
U - SEWER TIE IN 08/10/2016 CANCELLED BY APPLICANT MBACON
Note: THIS IS A REINSPECTION
GRAVITY SEWER TEST 08/10/2016 CANCELLED BY APPLICANT CMINI
Note: THIS IS A REINSPECTION
GRAVITY SEWER TEST 08/04/2016 Disapproved -FEE REQUIRED LMILLER
Note: UNCOVER WORK TO BE INSPECTED..FBC...P2503.2 10ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.4,
U - SEWER TIE IN 08/04/2016 Disapproved - NO FEE JNICHOLS
Note: the sewer tap was buried. it needs to be exposed so that we can see the connection.
FOUND SURVEY APPROVED (OFFICE) 08/02/2016 APPROVED DREWIS
MONOLITHIC SLAB 07/18/2016 APPROVED LMILLER
PLUMBING 1ST ROUGH UNDERGROUND 07/12/2016 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
PLFM COMPLETE 03/09/2017 03/09/2017
ELEC COMPLETE 03/08/2017 03/08/2017
SW1 COMPLETE 02/27/2017 03/02/2017
Note: Released By: FREODICA final survey Field verified by Gary Lalima.
PLFM COMPLETE 02/15/2017 02/15/2017
Note: No comments at this stage.
SW1 HOLD 02/14/2017 02/16/2017
Note: Held By: FREODICA final s 1. Drainage flow shall match with prposed plan. 2. Provide grading elevations at 20 foot intervals along the property line and at 10 foot offset to adjacent properties.. 3. Drainage flow to the ditch at left side of the house.is not allowed.
PLFM COMPLETE 08/16/2016 08/16/2016
PLFM HOLD 08/15/2016 08/15/2016
Note: Section A9(a) requires a sq. ft. calculation. A garage elevation is indicated in Section C2(d). Please note that A9(a) reflected a “560” sq. ft. calculation on the previously submitted elevation certificate. Please also note that measurement used for “N/A” entries for Section C2(a) – C2(f) can be deselected for each type.
PLFM HOLD 08/02/2016 08/03/2016
Note: Held By: DBEVAN The first elevation certificate (Construction Drawings) indicated a 1A construction for Section A7. On the elevation certificate (Building Under Construction) being reviewed, Section A7 notes a 1B (stem wall) construction. Confirm the correct Building Diagram Number.
BLD COMPLETE 05/23/2016 05/24/2016
URB COMPLETE 05/06/2016 05/06/2016
ELEC COMPLETE 05/06/2016 05/06/2016
PLFM COMPLETE 05/06/2016 05/06/2016
MECH COMPLETE 05/06/2016 05/09/2016
PLFM HOLD 04/28/2016 05/02/2016
Note: For Section B9, the elevation shall be indicated to the tenths. For example, “ 9.0’ ” would be found acceptable.
BLD COMPLETE 04/28/2016 05/02/2016
ELEC HOLD 04/28/2016 04/29/2016
Note: Provide: Code to be referenced. Location of panel to determine if disconnects are needed per NEC 2011 422 & 440.14. -DC. Rewis 986-4736
ENGIN1 COMPLETE 04/28/2016 04/28/2016
MECH HOLD 04/28/2016 05/02/2016
Note: 1. Provide balanced return air from craft room per FBCR 5th ed. M1602.4. 2. Insulation R-value of adjacent exterior wood frame wall (item 9b) of energy calculation shall be updated to R-13 to comply with FBCEC 5th ed. T-R402.1.1. F.N.Reodica-386-986-4734.
PLUM COMPLETE 04/28/2016 05/02/2016
SW1 COMPLETE 04/28/2016 04/29/2016
UD1 COMPLETE 04/28/2016 05/02/2016
ZON COMPLETE 04/28/2016 04/28/2016
URB HOLD 04/28/2016 04/28/2016
Note: Lots over 1/2 acre require submittal of an Irrigation Plan
SW1 COMPLETE 08/02/2016
Note: Released By: DREWIS

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 03/13/2017
REINSPECTION FEE ¤40.00 03/10/2017
REINSPECTION FEE ¤40.00 03/09/2017
REINSPECTION FEE ¤40.00 03/08/2017
REINSPECTION FEE ¤40.00 03/08/2017
REINSPECTION FEE ¤40.00 03/08/2017
REINSPECTION FEE ¤40.00 03/08/2017
REINSPECTION FEE ¤40.00 03/08/2017
REINSPECTION FEE ¤40.00 03/08/2017
REINSPECTION FEE ¤40.00 03/08/2017
REINSPECTION FEE ¤40.00 03/08/2017
REINSPECTION FEE ¤40.00 03/08/2017
REINSPECTION FEE ¤40.00 03/08/2017
REINSPECTION FEE ¤40.00 03/08/2017
ADMIN FEE ¤20.00 05/09/2016
ELECTRIC FEE ¤300.00 05/09/2016
3% FIRE IMPACT FEE CREDIT (¤6.38) 05/09/2016
IMPACT FEE FIRE NONRESIDENTIAL ¤212.80 05/09/2016
IMPACT FEE PARKS ¤849.24 05/09/2016
IMPACT FEE SCHOOL ¤3,600.00 05/09/2016
IMPACT FEE TRANSPORTATION ¤3,124.67 05/09/2016
MECHANICAL FEE ¤300.00 05/09/2016
3% PARKS IMPACT FEE CREDIT (¤25.48) 05/09/2016
PLAN CHECK FEE ¤160.00 05/09/2016
PLUMBING FEE ¤300.00 05/09/2016
NEW RESIDENTIAL INSPECTIONS ¤800.00 05/09/2016
SITE PLAN 20 ¤20.00 05/09/2016
SURCHARGE FS 533.721 ¤28.94 05/09/2016
SURCHARGE - FS 468.631 ¤28.94 05/09/2016
STORM WATER PERMIT FEES ¤80.00 05/09/2016
3% TRANS IMPACT FEE CREDIT (¤93.74) 05/09/2016
Fees Total Due: ¤0.00 Total Paid: ¤10,258.99