Permit #2016041049
Permit Details
Status: COED
| Parcel Id: 16-11-30-0000-01010-0020 |
| Block: 01010 |
| Subdivision: - |
| Job Phone: 386-313-6950 |
| Location Address: 77 HARGROVE GRADE |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 06/14/2016 |
| NOC: RECORDED |
| Applicant name: MARK ANTHONY LANGELLO |
| Owner: QUALITY EXPERTS TRANSPORTATION LLC |
|
Address 77 HARGROVE GRADE PALM COAST, FL 32164 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤105,000.00 |
| Job Description: REMODEL OFFICE BUILDING, REPLACE ROOF & WINDOWS |
| Type: CN |
Contractor
M & M DEVELOPMENT & CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| CANCEL |
2323 N. STATE ST BUNNELL, FL 32110 |
RG291103911 (Exp: 08/31/2023) | 386-313-6950 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
FREDERIK L SOORSMA
| Status | Location Address | State License Number | Phone |
| CANCEL |
603 15TH STREET ORMOND BEACH, FL 32174 |
CAC1816292 (Exp: 08/31/2024) | 386-214-5830 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
GLENN JAMES CANFIELD
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1519 RIDGEWOOD AVE HOLY HILL, FL 32117 |
CCC1328275 (Exp: 08/31/2024) | 386-257-6199 | 386-257-0556 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 12/15/2016 | APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING FINAL | 12/13/2016 | APPROVED | CMINI |
| HVAC FINAL | 12/13/2016 | APPROVED | CMINI |
| ELECTRIC FINAL | 12/13/2016 | Disapproved - NO FEE | CMINI |
| Note: (A) Working Space. Working space for equipment operating at 600 volts, nominal, or less to ground and likely to require examination, adjustment, servicing, or maintenance while energized shall comply with the dimensions of 110.26(A)(1), (A)(2), and (A)(3) or as required or permitted elsewhere in this Code.1) Depth of Working Space. The depth of the working space in the direction of live parts shall not be less than that specified in Table 110.26(A)(1) unless the requirements of 110.26(A)(1)(a), (A)(1)(b), or (A)(1)(c) are met. Distances shall be measured from the exposed live parts or from the enclosure or opening if the live parts are enclosed.(2) Width of Working Space. The width of the working space in front of the electrical equipment shall be the width of the equipment or 762 mm (30 in.), whichever is greater. In all cases, the work space shall permit at least a 90 degree opening of equipment doors or hinged panels. (3) Height of Working Space. The work space shall be clear and extend from the grade, floor, or platform to a height of 2.0 m (61/2 ft) or the height of the equipment, whichever is greater. Within the height requirements of this section, other equipment that is associated with the electrical installation and is located above or below the electrical equipment shall be permitted to extend not more than 150 mm (6 in.) beyond the front of the electrical equipment | |||
| BUILDING FINAL | 12/13/2016 | APPROVED | CMINI |
| FIRE FINAL | 12/13/2016 | APPROVED | JHINDMAN |
| U - UTILITY COMMERCIAL FINAL | 12/13/2016 | FINAL APPROVED | JNICHOLS |
| ELECTRIC - EARLY POWER | 11/28/2016 | APPROVED - AS NOTED | CMINI |
| Note: RELEASED POWER AT 2:40 PM SUSAN | |||
| LINTEL | 11/28/2016 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION. approved per revision | |||
| ABOVE CEILING | 11/28/2016 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ABOVE CEILING | 11/23/2016 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: 1. several grid wires are not tied to the grid.5th ed. FBC 808.1.1.1. 2. Air ducts in the restrooms are not installed in the grid. 5th edition Florida Building Code Mech 603.1.8. | |||
| FRAMING | 09/22/2016 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 2ND ROUGH | 09/22/2016 | APPROVED | CMINI |
| FRAMING | 09/21/2016 | Disapproved - NO FEE | JCOLASANTI |
| Note: THIS IS A REINSPECTIONneed to verify metel stud use. must be marked om plans. current detail calls for wood studs | |||
| ELECTRIC 2ND ROUGH | 09/08/2016 | APPROVED - AS NOTED | RMARTIN |
| Note: WALLS ONLY, CHECK TORQUE AND PANELS ON EARLY POWER | |||
| HVAC ROUGH | 08/30/2016 | APPROVED | CMINI |
| FRAMING | 08/01/2016 | PARTIALLY APPROVED | JCOLASANTI |
| Note: roof connection detail per revision OK | |||
| MONOLITHIC SLAB | 07/01/2016 | APPROVED - AS NOTED | JCOLASANTI |
| Note: Inspection Resulted at 7/1/2016 11:25:16 AM NEED CITY APPROVED REVISION ON SITE AT TIME OF NEXT INSPECTION. | |||
| PLUMBING 1ST ROUGH | 06/30/2016 | APPROVED | CMINI |
| LINTEL | 06/24/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 6/24/2016 11:38:21 AM PLANS CALL FOR #5 BARS TO BE INSTALLED. NEED TO REPLACE THE BARS TO AND INSTALL #5 OR GET A REVISION TO MATCH CURRENT SITE CONDITIONS. |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 11/22/2016 | 11/30/2016 |
| BLD | COMPLETE | 07/07/2016 | 07/08/2016 |
| BLD | COMPLETE | 07/05/2016 | 07/05/2016 |
| BLD | HOLD | 06/30/2016 | 07/05/2016 |
| Note: 1. Provide product approval for open steel supports for the roofing. The product approval listed is for installation over wood supports not open steel supports. 5th edition Florida building code 1503.1. J. Hindman 986-3784. | |||
| BLD | COMPLETE | 06/03/2016 | 06/13/2016 |
| MECH | COMPLETE | 06/03/2016 | 06/14/2016 |
| BLD | HOLD | 05/24/2016 | 05/25/2016 |
| Note: 1. Provide fire retardant wood in type 2b construction 5th ed. FBC 603.1 J. Hindman 986-3784 | |||
| MECH | HOLD | 05/24/2016 | 05/25/2016 |
| Note: 1. The total distributed supply air in CFM by each air handling unit (AHU) does not match with its capacity. Coordinate for clarity per FBC 5th ed. 107.2.1. 2, The transfer grille sizes for the balanced return air shall comply with FBCM 5th ed. 601.5. F.Reodica | |||
| PLUM | COMPLETE | 05/24/2016 | 05/24/2016 |
| FI1 | COMPLETE | 05/02/2016 | 05/04/2016 |
| MECH | HOLD | 05/02/2016 | 05/05/2016 |
| Note: Provide complete duct system layout to include but not limited to: Identify air handling units (AHU) and provide distributed CFM(s) by each AHU, return air and outside air duct layout including duct sizes, duct material, duct supports per FBCM 5th ed. chapter 6/FBC 5th ed. 107.3.5. F.N.Reodica -386-986 -4734. | |||
| PLUM | HOLD | 05/02/2016 | 05/05/2016 |
| Note: Lavatory and hand sink shall be vented per FBCP 5th ed. 910. FReodica-386-986-4734. | |||
| UD1 | COMPLETE | 05/02/2016 | 05/02/2016 |
| ZON | COMPLETE | 05/02/2016 | 05/04/2016 |
| SW1 | COMPLETE | 05/02/2016 | 05/02/2016 |
| BLD | HOLD | 05/02/2016 | 05/04/2016 |
| Note: 1. Provide Florida product approval numbers for the storefront, doors and roofing. 5th edition Florida building code 107.2.1. J. Hindman 986-3784. | |||
| ELEC | COMPLETE | 05/02/2016 | 05/04/2016 |
| Note: Cover sheet lists the NEC 2014(please remove). Sheet E3 lists the correct code to be referenced (NEC 2011) -DC. Rewis 986-4736 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 12/09/2016 |
| REINSPECTION FEE | ¤40.00 | 12/09/2016 |
| REVISION | ¤40.00 | 12/09/2016 |
| REVISION | ¤40.00 | 12/09/2016 |
| REVISION | ¤40.00 | 12/09/2016 |
| CONTRACTOR CHANGE | ¤40.00 | 12/09/2016 |
| CONTRACTOR CHANGE | ¤40.00 | 12/09/2016 |
| ELECTRIC FEE | ¤123.00 | 06/14/2016 |
| FIRE PLANS REVIEW | ¤25.00 | 06/14/2016 |
| MECHANICAL FEE | ¤123.00 | 06/14/2016 |
| PLAN CHECK FEE | ¤120.75 | 06/14/2016 |
| PLUMBING FEE | ¤123.00 | 06/14/2016 |
| ADMIN COMMERCIAL | ¤60.00 | 06/14/2016 |
| INSPECTION - COMMERCIAL ADD | ¤735.00 | 06/14/2016 |
| SITE PLAN 20 | ¤20.00 | 06/14/2016 |
| SURCHARGE FS 533.721 | ¤8.68 | 06/14/2016 |
| SURCHARGE - FS 468.631 | ¤8.68 | 06/14/2016 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤1,627.11 |