I want to search for...

Permit #2016050725

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00430-0020
CONDITIONED SPACE: 3230 sqft
GARAGE: 572 sqft
OPENED PORCH (WITH ROOF) : 110 sqft
Total Square Footage: 3912 sqft
Block: 00430
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 904-268-7730
Location Address: 2 ESSAY WAY
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/11/2016
NOC: RECORDED
Applicant name: KENNETH WAYNE CAMPBELL JR
Owner: MARONDA HOMES, INC OF FL. CORP

Address

9700 PHILIPS HWY

JACKSONVILLE, FL 32256

Address

SUITE 102

JACKSONVILLE, FL 32256

Lot: 0020
Contracted Stated Job Value: ¤133,939.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MARONDA HOMES INC. OF FLORIDA
Status Location Address State License Number Phone Fax
CANCEL

6800 SOUTHPOINT PKWAY SUITE 300

JACKSONVILLE, FL 32216

CBC058803 (Exp: 08/31/2018) 904-268-7730 904-268-7740

Sub Contractors

JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
DEBORAH MAXINE JACKSON
Status Location Address State License Number Phone Fax
CANCEL

9474 OLD PLANK RD

JACKSONVILLE , FL 32220

CCC1328530 (Exp: 08/31/2016) 904-435-7663 904-404-8406
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
GARI STINE
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

7225 JACKSONVILLE CT

WINTER PARK, FL 32792

SUITE 1

JACKSONVILE, FL 32256

CAC1818134 (Exp: 08/31/2020) 407-629-6920 407-629-9307

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/28/2017 FINAL APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROW - FINAL INSPECTION 02/28/2017 APPROVED CTROHA
Note: THIS IS A REINSPECTION ALL WORK COMPLETE
U -UTILITY RESIDENTIAL FINAL 02/27/2017 FINAL APPROVED MBACON
BLD - BUILDING FINAL 02/27/2017 Disapproved -FEE REQUIRED DROCKWELL
Note: Systems ground wire loose-tighten/Repair hole in exterior wall at pest tubes/Plate does not cover hole at ground rod connection right side/Turn on water to house/Grout pedestal sink where it meets wall top and sides/Install attic access cover
FINAL SURVEY (OFFICE USE ONLY) 02/24/2017 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
FINAL SURVEY (OFFICE USE ONLY) 02/23/2017 Disapproved - NO FEE CMINI
Note: not a call in inspection, need to submit to office
ROW - FINAL APRON (AFTER POUR) 02/23/2017 APPROVED CTROHA
ROW - FINAL INSPECTION 02/23/2017 Disapproved -FEE REQUIRED CTROHA
Note: REMOVE LARGE TREE STUMP ON LSPL AT THE TOP OF SWALE AS PER MUNICIPLE CODE CH9-905
ELECTRIC - EARLY POWER 02/16/2017 APPROVED DROCKWELL
ROW- PRE-APRON (PRE-POUR) 02/08/2017 APPROVED CTROHA
Note: THIS IS A REINSPECTION L=26.55 R=26.47 READY TO POUR It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the specs shown on the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete.
ROW- PRE-APRON (PRE-POUR) 02/07/2017 Disapproved -FEE REQUIRED CTROHA
Note: CULVERT PIPE ISN'T CENTERED IN THE DRIVEWAY ITS TOO FAR TO THE LEFT ANY QUESTIONS CALL 386-517-3403
U - SEWER TIE IN 02/02/2017 APPROVED DSPENCER
LATH/BRICK/ WATER BARRIER 01/17/2017 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 01/13/2017 CANCELLED BY APPLICANT DROCKWELL
INSULATION 01/03/2017 APPROVED - AS NOTED DROCKWELL
Note: THIS IS A REINSPECTION Install baffels around upper attic access as so loose fill insulation does not spill into living area.when hatch is opened
INSULATION 12/27/2016 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION 1. FIREBLOCKING R302.11 (4) PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVEL (WITH APPROVED MATERIAL) (PLUMBING CHASE IN A/C CLOSET) 2. R-VALUE MUST BE MARKED ON EACH PIECE OF INSULATION R303.1.1.2 AND R303.1.1.2.2 R-VALUE MARK MUST BE MARKED ON EACH PIECE OF UNSULATION MATERIAL AND READILY OBSERVABLE FOR INSPECTION NOTE: (NAIL PLATE NOTED AT ALL ROUGH RESOLVED)
INSULATION 12/21/2016 CANCELLED BY APPLICANT DROCKWELL
ALL ROUGH 12/16/2016 APPROVED - AS NOTED DROCKWELL
Note: Nail plate at vent pipe down bath top plate before insulation
ALL ROUGH 12/14/2016 CANCELLED BY APPLICANT AIRS WEB
Note: THIS IS A REINSPECTION
ALL ROUGH 12/09/2016 Disapproved -FEE REQUIRED DROCKWELL
Note: No test on sanitary lines/No pressure on supply side/Support dryer duct at mid-point to roof deck/ FYI Shingles need to be in place before this inspection to protect insulated duct work from getting wet.
ROOF VALLEY & METAL 12/06/2016 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF VALLEY & METAL 12/02/2016 Disapproved -FEE REQUIRED LMILLER
Note: NOT READY, NO METAL APPLIED
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/18/2016 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
WALL SHEATHING 11/15/2016 APPROVED - AS NOTED DROCKWELL
Note: Exterior wall strapping in place----Dry in
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/14/2016 Disapproved -FEE REQUIRED LMILLER
Note: NOT READY, (TRUSSES STILL BEING SET, NO DECKING APPLIED, STRAPS NOT COMPLETE)
TIE BEAM / LINTEL 10/25/2016 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 10/24/2016 Disapproved -FEE REQUIRED LMILLER
Note: 1.OVERBEND DOWEL BAR FBC R606.13.3 EXCEPTION (DRILL AND EPOXY, MARKED WITH ORANGE PAINT) 2. DOWN CELLS R609.1.4, ALL CELLS CONTAINING REINFORCEMENT SHALL BE GROUTED SOLID (CLEAN OUT DEBRIS, CHECK ALL)
FOUND SURVEY APPROVED (OFFICE) 10/17/2016 APPROVED FREODICA
MONOLITHIC SLAB 10/13/2016 APPROVED LMILLER
PLUMBING 1ST ROUGH UNDERGROUND 09/30/2016 APPROVED DROCKWELL
GRAVITY SEWER TEST 09/30/2016 APPROVED DROCKWELL
FOOTER 09/13/2016 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
SW1 COMPLETE 10/17/2016 10/17/2016
Note: Released By: FREODICA FOUNDATION S
BLD COMPLETE 08/30/2016 08/30/2016
ELEC COMPLETE 08/04/2016 08/05/2016
ELEC HOLD 07/29/2016 08/03/2016
Note: Receptacle for flex room is not for the exterior of home, it is for the interior, NEC 201.52. -DC. Rewis 986-4736
PLENV COMPLETE 07/29/2016 08/01/2016
Note: Staff has reviewed and found the gopher tortoise relocation after action report acceptable.
BLD COMPLETE 06/29/2016 06/30/2016
ENGIN1 COMPLETE 06/28/2016 06/30/2016
ZON COMPLETE 06/28/2016 06/29/2016
PLENV HOLD 06/28/2016 07/08/2016
Note: Staff is aware that the Applicant has secured the services of a certified gopher tortoise agent to address the onsite tortoises. A an after-action report will be required prior to issuing a building permit.
PLUM COMPLETE 06/28/2016 06/30/2016
ELEC HOLD 06/28/2016 06/30/2016
Note: Provide a receptacle on the exterior wall of flex room, NEC 2011 210.52. -DC. Rewis 986-4736
ZON HOLD 06/10/2016 06/13/2016
Note: Repeat Comment: Banding or shutters is required around all DOORS facing public right-of-way.
ELEC COMPLETE 06/10/2016 06/10/2016
PLUM HOLD 06/10/2016 06/16/2016
Note: Provide sanitary riser diagram for the second floor per FBC 5th ed. 107.2.1. F.Reodica-386-986-4734. 2nd request
PLENV HOLD 06/10/2016 06/13/2016
Note: As noted in the first review cycle, the existing gopher tortoise burrow and associated actions shall be addressed pursuant to the following. On May 16, 2016, an active gopher tortoise burrow and individual was observed on the subject property. Please provide a gopher tortoise survey by a qualified environmental professional that a burrow does not exist on or within 25 feet of the proposed construction activities. Please note that an active list of professionals determined to have met QEP criteria is currently maintained by the City’s Environmental Planner and available upon request. Contact of Environmental Planner: Denise Bevan, dbevan@palmcoastgov.com 386-986-2458.
ENGIN1 HOLD 06/10/2016 06/10/2016
Note: Held By: JHOWARD Provide a benchmark clearly marked on the site plan. Ensure the benchmark is in NAVD88 Datum.
PLENV HOLD 05/25/2016 05/27/2016
Note: On May 16, 2016, an active gopher tortoise burrow and individual was observed on the subject property. Please provide a gopher tortoise survey by a qualified environmental professional that a burrow does not exist on or within 25 feet of the proposed construction activities. Please note that an active list of professionals determined to have met QEP criteria is currently maintained by the City’s Environmental Planner and available upon request. For more information and guidance, contact Denise Bevan, dbevan@palmcoastgov.com 386-986-2458.
BLD COMPLETE 05/24/2016 05/25/2016
ELEC HOLD 05/24/2016 05/25/2016
Note: 1. Provide receptacle on exterior wall in Flex space room. 2011 NEC 210.52. J. Hindman 986-3784.
ENGIN1 HOLD 05/24/2016 05/24/2016
Note: Provide a benchmark clearly marked on the site plan. Ensure that the benchmark is in NAVD88 Datum and labeled accordingly.
MECH COMPLETE 05/24/2016 05/25/2016
PLUM HOLD 05/24/2016 05/25/2016
Note: Provide sanitary riser diagram for the second floor per FBC 5th ed. 107.2.1. F.Reodica-386-986-4734.
SW1 COMPLETE 05/24/2016 05/25/2016
UD1 COMPLETE 05/24/2016 05/25/2016
ZON HOLD 05/24/2016 05/25/2016
Note: Banding or shutters is required around all windows or DOORS facing public right-of-way.
URB COMPLETE 05/24/2016 05/25/2016

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00 02/28/2017
CONTRACTOR CHANGE ¤40.00 02/28/2017
CONTRACTOR CHANGE ¤40.00 02/28/2017
REINSPECTION FEE ¤40.00 02/28/2017
REINSPECTION FEE ¤40.00 02/28/2017
REINSPECTION FEE ¤40.00 02/28/2017
REINSPECTION FEE ¤40.00 02/28/2017
REINSPECTION FEE ¤40.00 02/28/2017
REINSPECTION FEE ¤40.00 02/28/2017
REINSPECTION FEE ¤40.00 02/28/2017
REINSPECTION FEE ¤40.00 02/28/2017
REVISION ¤40.00 02/28/2017
SITE PLAN 20 ¤20.00 08/11/2016
SURCHARGE FS 533.721 ¤27.56 08/11/2016
SURCHARGE - FS 468.631 ¤27.56 08/11/2016
STORM WATER PERMIT FEES ¤80.00 08/11/2016
3% TRANS IMPACT FEE CREDIT (¤93.74) 08/11/2016
ADMIN FEE ¤20.00 08/11/2016
NEW RESIDENTIAL INSPECTIONS ¤770.00 08/11/2016
ELECTRIC FEE ¤291.00 08/11/2016
3% FIRE IMPACT FEE CREDIT (¤6.38) 08/11/2016
IMPACT FEE FIRE NONRESIDENTIAL ¤212.80 08/11/2016
IMPACT FEE PARKS ¤849.24 08/11/2016
IMPACT FEE SCHOOL ¤3,600.00 08/11/2016
IMPACT FEE TRANSPORTATION ¤3,124.67 08/11/2016
MECHANICAL FEE ¤291.00 08/11/2016
3% PARKS IMPACT FEE CREDIT (¤25.48) 08/11/2016
PLAN CHECK FEE ¤154.00 08/11/2016
PLUMBING FEE ¤291.00 08/11/2016
Fees Total Due: ¤0.00 Total Paid: ¤10,113.23