I want to search for...

Permit #2016070144

Permit Details

Status: COED

Parcel Id: 16-11-30-4915-00010-05F0
Block: 00010
Subdivision: 1150 - PALM COAST COMMERCIAL & INDUSTRIAL CENTER
Job Phone: 386-445-9055
Location Address: 15 HARGROVE LN
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 09/16/2016
NOC: RECORDED
Applicant name: LUIS JORGE MEDEIROS
Owner: DISANTO, LOUIS & VIEIRA, LAUDELINO

Address

42 WESTMOUNT LANE

PALM COAST, FL 32164

Lot: 05F0
Contracted Stated Job Value: ¤10,000.00
Job Description: SUITE 5-F-- BUILDOUT FOR BAKERY OVENS & GREASE TRAP- "LUSO AMERICA CAFE & BAKERY"
Type: CN

Contractor

SUN STATE CUSTOM BUILDERS, LLC
Status Location Address State License Number
CANCEL

946 SHADICH DRIVE

ORANGE CITY, FL

CGC1519145 (Exp: 08/31/2022)

Sub Contractors

JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144
JOHN ROBERT BLEVINS JR
Status Location Address State License Number Phone Fax
ACTIVE

17 PORWYN LANE

PALM COAST, FL 32164

CAC1816125 (Exp: 08/31/2026) 386-585-8283 386-263-2096

Inspection History

Type Request Date Result Inspector
U - UTILITY COMMERCIAL FINAL 01/10/2017 FINAL APPROVED JNICHOLS
BUILDING FINAL 12/29/2016 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
FIRE FINAL 11/22/2016 FINAL APPROVED JHINDMAN
Note: THIS IS A REINSPECTION PER CUSTOMERS
FIRE FINAL 11/09/2016 Disapproved -FEE REQUIRED JHINDMAN
Note: 1. batteries in emergency lights do not work. 5th ed. FFPC 101 7.9. 2. seal penetrations in ceiling at electrical cables 5th ed. FFPC 101 8.1
BUILDING FINAL 11/09/2016 Disapproved - NO FEE JHINDMAN
Note: hood permit has not been issued and inspected for the duct and exhaust fan that has been installed. 5th ed. FBC 105.1.
ELECTRIC FINAL 11/08/2016 FINAL APPROVED RMARTIN
PLUMBING FINAL 10/17/2016 APPROVED CMINI
ELECTRIC 2ND ROUGH 10/11/2016 APPROVED JHINDMAN
PLUMBING 2ND ROUGH 10/04/2016 PARTIALLY APPROVED CMINI
Note: 1st rough
U-GREASE INTERCEPTOR FLOW/DYE TESTED 10/04/2016 APPROVED JNICHOLS
U-GREASE INTERCEPTOR PRE-INSTALLATION 09/29/2016 APPROVED DSPENCER
U-GREASE INTERCEPTOR INSTALLED/PLUMBED 09/29/2016 APPROVED DSPENCER

Review History

Department Status Date In Date Out
MECH COMPLETE 09/13/2016 09/13/2016
MECH HOLD 08/26/2016 08/30/2016
Note: Review comment based submitted correction dated 8-26-16: 1. Clarify the location of make up air for the new work area as floor plan shows the air intake opening penetrates through an existing tenant separation wall and not from the outside wall per FBC 5th ed. 107.2.1. 2. Provide heating for the new work area per FBCM 5th ed. 309. 3. Provide gas contractor and gas riser diagram for the oven with signature and license number of gas contractor per FS 489/FBC 5th ed. 107.2.1. 4. Clarify the capacity of the make up air and coordinate with the required ventilation for the gas oven per manufacturer's installation instructions FBC 5th ed. 107.2.1.F.Reodica -386-986-4734.
PLUM COMPLETE 08/04/2016 08/09/2016
MECH HOLD 08/04/2016 08/09/2016
Note: Previous comment item 2 shall be addressed. 2. Provide existing hvac duct layout to comply with FBC existing building 5th ed. 809. F.Reodica-386-986-4734. Note: Additional comments might be added for additional information if existing hvac system can not handle the new converted space.
ELEC COMPLETE 08/04/2016 08/05/2016
UD1 COMPLETE 08/04/2016 08/05/2016
ZON COMPLETE 08/04/2016 08/08/2016
BLD COMPLETE 08/04/2016 08/08/2016
FI1 COMPLETE 08/04/2016 08/08/2016
BLD HOLD 07/07/2016 07/14/2016
Note: 1. Provide correct occupancy types. (factory-1 and mercantile) per 5th edition Florida building code 306 and 309. 2. Provide a bathroom door that meets 5th edition Florida Building code Accessibility 603.2.3 The door cannot swing into the required clear floor space for a fixture. J. Hindman 986-3784.
ELEC HOLD 07/07/2016 07/08/2016
Note: Mixer roller needs a disconnect, NEC 2011 422 part three. -DC. Rewis 986-4736
FI1 HOLD 07/07/2016 07/14/2016
Note: 1.Remove the exit sign at the overhead doo rand relocate it to the bakery side of the office door. The overhead door does not meet the requirements for an Exit door 5th ed. FFPC 7.2.1. J. Hindman 986-3784.
MECH HOLD 07/07/2016 07/14/2016
Note: 1. Provide separate permit for oven hood per FBC 5th ed. 107.2.1. 2. Provide existing hvac duct layout to comply with FBC existing building 5th ed. 809. F.Reodica-386-986-4734.
PLUM HOLD 07/07/2016 07/14/2016
Note: 1. Provide plumbing riser diagrams (sanitary and domestic hot and cold) water per FBC 5th ed. 107.3.5. F.Reodica -386-986-4734.
UD1 HOLD 07/07/2016 07/11/2016
Note: Provide approved grease interceptor exemption form and grease trap specifications. Contact me for exemption form. Provide completed DBPR form. CJohnson 386-986-2384
ZON HOLD 07/07/2016 07/11/2016
Note: Per the Land Development Code this use is allowed by Special Exception. In order to allow this use a Special Exception application must be applied for, reviewed and heard at the next applicable Planning Board hearing. Please call Damaris Ramirez at 986-3750 for an application and a checklist of items that will be needed for review prior to scheduling a public hearing.
SW1 COMPLETE 07/07/2016 07/07/2016
PLUM HOLD 07/14/2016
Note: 1. Provide plumbing riser diagrams (sanitary and domestic hot and cold) water either prepared by plumbing contractor with signature and license number or design professional per FBC 5th ed. 107.3.5./ 107.2.1. 2. Provide service sink per FBCP 5th ed. 403. F.Reodica -386-986-4734.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 01/09/2017
SITE PLAN 20 ¤20.00 09/16/2016
SURCHARGE FS 533.721 ¤5.67 09/16/2016
SURCHARGE - FS 468.631 ¤5.67 09/16/2016
ADMIN COMMERCIAL ¤60.00 09/16/2016
INSPECTION - COMMERCIAL ADD ¤70.00 09/16/2016
CONTRACTOR CHANGE ¤40.00 09/16/2016
ELECTRIC FEE ¤66.00 09/16/2016
FIRE PLANS REVIEW ¤25.00 09/16/2016
MECHANICAL FEE ¤66.00 09/16/2016
PLAN CHECK FEE ¤100.00 09/16/2016
PLUMBING FEE ¤66.00 09/16/2016
Fees Total Due: ¤0.00 Total Paid: ¤564.34