Permit #2016070499

Permit Details

Status: COED

Parcel Id: 42-10-30-3210-00000-3390
CONDITIONED SPACE: 2471 sqft
GARAGE: 449 sqft
OPENED PORCH (WITH ROOF) : 250 sqft
OPENED PORCH (WITH ROOF) : 36 sqft
Total Square Footage: 3206 sqft
Block: 00000
Subdivision: 2094 - CONSERVATORY AT HAMMOCK BEACH
Job Phone: (386)383-0376
Location Address: 248 CONSERVATORY DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/08/2016
NOC: RECORDED
Applicant name: ANTHONY CRAIG GUCCIONE
Owner: OCHITWA, DONALD W & GINETTE

Address

115 SEMINOLE DR

NORTH BARRINGTON, IL 60010

Lot: 3390
Contracted Stated Job Value: ¤300,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

GOLD COAST HOME BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 354707

PALM COAST, FL 32137

CGC1507791 (Exp: 08/31/2026) 386-313-6221

Sub Contractors

BERT S MCLAUGHLIN
Status Location Address State License Number Phone
ACTIVE

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

EC13006455 (Exp: 08/31/2026) 386-265-2687
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32136

CAC048127 (Exp: 08/31/2018) 386-445-5023 386-446-4614
JOHN BRADLEY WINFREY JR
Status Location Address State License Number Phone Fax
ACTIVE

1685 S. CLARA AVE

Deland, FL 32720

CFC054901 (Exp: 08/31/2026) 386-734-0154 386-734-2751
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937

Inspection History

Type Request Date Result Inspector
ROW - FINAL INSPECTION 04/28/2017 APPROVED - AS NOTED RGROSS
Note: THIS IS A REINSPECTION. IN THE FUTURE ALL SET BACK AREAS OF THE POND MUST REMAIN NATURAL VEGETATION OR COVERED WITH SPARTINA PLANTS IF AREA IS DISTURBED.
U -UTILITY RESIDENTIAL FINAL 04/28/2017 FINAL APPROVED DSPENCER
ROW - FINAL APRON (AFTER POUR) 04/27/2017 APPROVED - AS NOTED RGROSS
Note: SUGGESTED THAT THE PAVERS SURROUNDING THE BRASS SEWER CLEANOUT BE GRINDED DOWN TO ELIMINATE THAT SHARP DEEP EDGE AROUND THE CAP
BLD - BUILDING FINAL 04/27/2017 FINAL APPROVED CMINI
ROW - FINAL INSPECTION 04/27/2017 Disapproved -FEE REQUIRED RGROSS
Note: NEED BAHIA SOD ALONG REAR BANK ON BOTH SIDES OF THE PROPERTY LINE TO AVOID A WASHOUT. ALSO NEED BAHIA SOD NEAR THE END OF THE SIDEWALK WHERE SEDIMENT CAN WASH OUT ONTO THE SIDEWALK AND MIAMI CURB. ON SITE WITH SUPER.
FINAL SURVEY (OFFICE USE ONLY) 04/26/2017 APPROVED FREODICA
U - SEWER TIE IN 02/24/2017 APPROVED JNICHOLS
ROW- PRE-APRON (PRE-POUR) 02/15/2017 APPROVED GLALIMA
Note: READY FOR PAVERS. IF ANY ISSUES CALL GARY LA LIMA. 585-0286
ELECTRIC - EARLY POWER 02/10/2017 APPROVED - AS NOTED CMINI
Note: CALLED FPL TO RELEASE POWER, SPOKE WITH SUSAN
LATH/BRICK/ WATER BARRIER 12/19/2016 APPROVED JCOLASANTI
INSULATION 12/15/2016 APPROVED CMINI
Note: THIS IS A REINSPECTION
INSULATION 12/14/2016 Disapproved -FEE REQUIRED LMILLER
Note: FIREBLOCKING R302.11 1-6 (MARKED BELOW ON STUDS WITH GREEN PAINT) FIREBLOCKING R302.11 (4) PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVEL (WITH APPROVED MATERIAL)
ALL ROUGH 12/08/2016 APPROVED CMINI
ROOF VALLEY & METAL 11/17/2016 APPROVED CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/09/2016 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/08/2016 CANCELLED BY APPLICANT JCOLASANTI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/07/2016 Disapproved -FEE REQUIRED CMINI
Note: missing straps on trusses and continuous load path, circled on roof plan
ELECTRIC-TUG 10/27/2016 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED TUG 2:05
TIE BEAM / LINTEL 09/30/2016 APPROVED CMINI
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 09/29/2016 Disapproved -FEE REQUIRED LMILLER
Note: 1. CLEARANCE FROM MASONRY R606.13.4 MINIMUM WALL REINFORCING STEEL COVERAGE NOT MET 2. OVERBEND DOWEL BAR FBC R606.13.3 EXCEPTION 26.. WITH A VERTICAL CELL NOT MORE THAN 1 1D OF HORIZONTAL DISPLACEMENT TO 6 1D OF VERTICAL BAR LENGTH. 3. DOWN CELLS R609.1.4, ALL CELLS CONTAINING REINFORCEMENT SHALL BE GROUTED SOLID (clean out openings) (ALL CIRCLED ON PLANS)
FOUND SURVEY APPROVED (OFFICE) 09/28/2016 APPROVED DREWIS
MONOLITHIC SLAB 09/01/2016 APPROVED - AS NOTED JCOLASANTI
Note: need density test sticker in boxfor next inspection
GRAVITY SEWER TEST 08/24/2016 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 08/24/2016 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
GRAVITY SEWER TEST 08/23/2016 Disapproved - NO FEE CMINI
Note: need to cut stack down to 10' for test or fill entire pipe to top. can not tell if DWV is holding fbc P2503.5.1
PLUMBING 1ST ROUGH UNDERGROUND 08/23/2016 Disapproved -FEE REQUIRED CMINI
Note: need to cut stack down to 10' for test or fill entire pipe to top. can not tell if DWV is holding fbc P2503.5.1

Review History

Department Status Date In Date Out
SW1 COMPLETE 04/26/2017 04/26/2017
Note: Released By: FREODICA final s
SW1 COMPLETE 09/28/2016 09/28/2016
Note: Released By: DREWIS foundation s
ENGIN1 COMPLETE 08/09/2016 08/09/2016
Note: Conservatory Drive is designed with curb and gutter; therefore, a swale plan is not required.
ZON COMPLETE 08/09/2016 08/11/2016
ELEC COMPLETE 07/21/2016 07/22/2016
MECH COMPLETE 07/21/2016 07/22/2016
PLUM COMPLETE 07/21/2016 07/22/2016
BLD COMPLETE 07/18/2016 07/18/2016
ELEC HOLD 07/18/2016 07/19/2016
Note: Provide the following receptacles: Exterior wall in front room by master bath, NEC 2011 201.52 A. Hallway between guest bath and kitchen, NEC 210.52 H. Please provide a disconnect for the AHU, NEC 440.14. Please provide load calculations per NEC 2011 220. -DC. Rewis 986-4736
ENGIN1 COMPLETE 07/18/2016 07/18/2016
Note: Conservatory Drive is designed with curb and gutter; therefore, a swale plan is not required.
MECH HOLD 07/18/2016 07/19/2016
Note: Energy performance level (EPL) display card shall be signed by the builder per FBCAEC 5th ed. R401.3. F.Reodica-386-986-4734.
PLUM HOLD 07/18/2016 07/19/2016
Note: Provide sanitary riser diagram per FBC 5th ed. 107.2.1. F.Reodica -386-986-4734.
SW1 COMPLETE 07/18/2016 07/19/2016
UD1 COMPLETE 07/18/2016 07/20/2016
ZON COMPLETE 07/18/2016 07/20/2016
URB COMPLETE 07/18/2016 07/19/2016

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 05/01/2017
REINSPECTION FEE ¤40.00 05/01/2017
REINSPECTION FEE ¤40.00 05/01/2017
REINSPECTION FEE ¤40.00 05/01/2017
REINSPECTION FEE ¤40.00 05/01/2017
NEW RESIDENTIAL INSPECTIONS ¤608.00 08/08/2016
SITE PLAN 20 ¤20.00 08/08/2016
SURCHARGE FS 533.721 ¤22.45 08/08/2016
SURCHARGE - FS 468.631 ¤22.45 08/08/2016
STORM WATER PERMIT FEES ¤80.00 08/08/2016
3% TRANS IMPACT FEE CREDIT (¤93.74) 08/08/2016
ADMIN FEE ¤20.00 08/08/2016
ELECTRIC FEE ¤242.40 08/08/2016
3% FIRE IMPACT FEE CREDIT (¤6.43) 08/08/2016
IMPACT FEE FIRE NONRESIDENTIAL ¤214.29 08/08/2016
IMPACT FEE PARKS ¤849.24 08/08/2016
IMPACT FEE SCHOOL ¤3,600.00 08/08/2016
IMPACT FEE TRANSPORTATION ¤3,124.67 08/08/2016
MECHANICAL FEE ¤242.40 08/08/2016
3% PARKS IMPACT FEE CREDIT (¤25.48) 08/08/2016
PLAN CHECK FEE ¤121.60 08/08/2016
PLUMBING FEE ¤242.40 08/08/2016
Fees Total Due: ¤0.00 Total Paid: ¤9,484.25