Permit #2016070774

Permit Details

Status: CANCEL

Parcel Id: 07-11-31-7037-01050-0040
CONDITIONED SPACE: 728 sqft
Total Square Footage: 728 sqft
Block: 01050
Subdivision: 2176 - SECTION 37-LAKEVIEW
Job Phone: 386-206-3150
Location Address: 8 LOUISIANA DR
Type: DBA - DETACHED BUILDING ADDITION
NOC: NO DOCUMENTATION
Applicant name: CHARLES M BURGAN III
Owner: OBRIEN, THERESA E & VALERIE D ROBERTS

Address

8 LOUISIANA DR

PALM COAST, FL 32164

Lot: 0040
Contracted Stated Job Value: ¤45,000.00
Job Description: 28 X 26 FT ADDITION
Type: CN

Contractor

CHARLES BURGAN, LLC
Status Location Address State License Number Phone Fax
INACTIVE

1132 HARDY ST

BUNNELL, FL 32110

CGC1512729 (Exp: 08/31/2026) 386-206-3150 386-206-3150

Sub Contractors

JOSEPH PAUL BERNHARD
Status Location Address State License Number Phone
CANCEL

5 RYECORN PLACE

PALM COAST, FL 32164

EC13004556 (Exp: 08/31/2026) 386-793-1358
CHARLES M BURGAN III
Status Location Address State License Number Phone Fax
INACTIVE

1132 HARDY ST

BUNNELL, FL 32110

CGC1512729 (Exp: 08/31/2026) 386-206-3150 386-206-3150
JONATHAN P DUCEY
Status Location Address State License Number Phone
ACTIVE

505 WEST COURT STREET

BUNNELL, FL 32110

CFC1427093 (Exp: 08/31/2026) 386-503-6092
JAMES KUYKENDALL
Status Location Address State License Number Phone Fax
CANCEL

2550 US 1 NORTH SUITE 3

BUNNELL, FL 32110

CAC1815546 (Exp: 08/31/2022) (386)437-2929 (386)437-2942

Inspection History

Type Request Date Result Inspector
FOUND SURVEY APPROVED (OFFICE)
FINAL SURVEY (OFFICE USE ONLY)
PLUMBING 1ST ROUGH UNDERGROUND
MONOLITHIC SLAB
FOOTER
STEM WALL FOUNDATION
TIE BEAM / LINTEL
ALL ROUGH
INSULATION
BLD - BUILDING FINAL

Review History

Department Status Date In Date Out
BLD HOLD 08/30/2016 08/30/2016
Note: 1. Provide coordinated drawings that do not conflict each other. The provided new page one does not contain the design specifications and notes from the original page one. The new page one does not show all of the elevations. The page three show a different plumbing riser and also show the range which differs from the new page one. 5th Edition Florida building Code 107.2.1. J. Hindman 986-3784.
ELEC HOLD 08/30/2016 08/30/2016
Note: 1) Calculated load shows 144amps for to a 100amp sub panel(B) being fed by a 200amp panel(A). 2) When utilizing NEC 2011 220.83B for existing units and adding the 144amp calculated load, the proposed calculations exceed the feeder amperage. -DC. Rewis 986-4736
ZON HOLD 08/30/2016 08/31/2016
Note: 1. Per LDC 4.01.01.A. - All accessory structures, other than fences and garages, shall be located behind the adjacent front or side street building footprint of the principal structure. 2. Primary structure appears to have a brick exterior and proposed accessory structure depicts siding. 3. Provide Single Family Dwelling Affidavit. This Affidavit must be signed by all persons on deed to property, and must be witnessed and notarized.
PLUM COMPLETE 08/30/2016 08/30/2016
MECH HOLD 08/30/2016 08/30/2016
Note: 1. Provide signature and license number of hvac contractor on hvac plan per FBC 5th ed. 107.2.1. 2. Energy performance level (EPL) display card on energy calculations shall be signed by the builder per FBCEC 5th ed. R401.3. 3. Directional orientation of the building shown on energy calculations shall match with the referenced North arrow on site plan per FBCEC 5th ed. R403.6.1. 4. Provide the manufacturer and model number of outdoor and indoor units per FBCEC 5th ed. R403.6.1. 5. Location of air handling unit shown on hvac plan does not match with floor plan. Coordinate for clarity per FBC 5th ed. 107.2.1. F.Reodica - 386-986-4734.
BLD HOLD 07/26/2016 07/27/2016
Note: 1. Provide detail for the steel in the front porch footings. 5th ed. FBC 107.2.1. 2. Provide a roof truss layout with truss to wall connections per Florida Administrative Code 61G15-31.003. J Hindman
SW1 COMPLETE 07/26/2016 08/01/2016
ZON HOLD 07/26/2016 07/28/2016
Note: 1. Proposed structure does not meet the minimum street side setback dimension required for this zoning district. 2. Per LDC 13.03.01.A. Duplex residential dwelling units shall have the same architectural design, materials and colors for both sides. 3. 13.03.02.A.2 - Pitched roofs shall have a minimum slope of 5:12. 4. 13.03.03.C.1 - Windowless exterior walls, excluding garage doors, that face a public right-of-way are prohibited. 5. Provide landscape plan noting as per 11.03.02.2.b - Foundation shrubbery plantings are required for side street house exposure and accessory structures facing public rights of way. 6. Duplex units must meet minimum dimensional standards as per LDC table 3-3. 7. Accessory structures to single family residential dwellings are not allowed to have a separate kitchen facility. 8. Accessoty structures must have have the same exterior (materials and colors) as the primary structure.
ELEC HOLD 07/26/2016 07/27/2016
Note: 1. Provide electrical load calculations for the house with the additional building's loads. 5th ed. FBC R E3602.2. 2. Provide GFCI receptacles at the kitchen counters spaced per 5th ed. FBC R E3901.4. 3. Provide a site specific Electrical riser diagram. 5th ed. FBC 107.2.1. 4. Identify the location and electrical specifications of the HVAC unit. 5th ed. FBC R E3702. J. Hindman 986-3784.
MECH HOLD 07/26/2016 07/28/2016
Note: Provide energy calculations, hvac plan and hvac contractor per FBCEC 5th ed. R405/FBC 5th ed. 107.2.1/FS 489. F.Reodica -386-986-4734.
PLUM HOLD 07/26/2016 07/28/2016
Note: Provide complete pipe sizes of fixture drains on sanitary riser diagram per FBC 5th ed. 107.2.1. F.Reodica - 386-986-4734.
ELEC CANCEL
BLD CANCEL
MECH CANCEL
ZON CANCEL

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00
Fees Total Due: ¤40.00 Total Paid: ¤0.00