I want to search for...
Permit #2016070774
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7037-01050-0040 |
| CONDITIONED SPACE: 728 sqft |
| Total Square Footage: 728 sqft |
| Block: 01050 |
| Subdivision: 2176 - SECTION 37-LAKEVIEW |
| Job Phone: 386-206-3150 |
| Location Address: 8 LOUISIANA DR |
| Type: DBA - DETACHED BUILDING ADDITION |
| NOC: NO DOCUMENTATION |
| Applicant name: CHARLES M BURGAN III |
| Owner: OBRIEN, THERESA E & VALERIE D ROBERTS |
|
Address 8 LOUISIANA DR PALM COAST, FL 32164 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤45,000.00 |
| Job Description: 28 X 26 FT ADDITION |
| Type: CN |
Contractor
CHARLES BURGAN, LLC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1132 HARDY ST BUNNELL, FL 32110 |
CGC1512729 (Exp: 08/31/2026) | 386-206-3150 | 386-206-3150 |
Sub Contractors
JOSEPH PAUL BERNHARD
| Status | Location Address | State License Number | Phone |
| CANCEL |
5 RYECORN PLACE PALM COAST, FL 32164 |
EC13004556 (Exp: 08/31/2026) | 386-793-1358 |
CHARLES M BURGAN III
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1132 HARDY ST BUNNELL, FL 32110 |
CGC1512729 (Exp: 08/31/2026) | 386-206-3150 | 386-206-3150 |
JONATHAN P DUCEY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
505 WEST COURT STREET BUNNELL, FL 32110 |
CFC1427093 (Exp: 08/31/2026) | 386-503-6092 |
JAMES KUYKENDALL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2550 US 1 NORTH SUITE 3 BUNNELL, FL 32110 |
CAC1815546 (Exp: 08/31/2022) | (386)437-2929 | (386)437-2942 |
Inspection History
| Type | Request Date | Result | Inspector |
| FOUND SURVEY APPROVED (OFFICE) | |||
| FINAL SURVEY (OFFICE USE ONLY) | |||
| PLUMBING 1ST ROUGH UNDERGROUND | |||
| MONOLITHIC SLAB | |||
| FOOTER | |||
| STEM WALL FOUNDATION | |||
| TIE BEAM / LINTEL | |||
| ALL ROUGH | |||
| INSULATION | |||
| BLD - BUILDING FINAL |
Review History
| Department | Status | Date In | Date Out |
| BLD | HOLD | 08/30/2016 | 08/30/2016 |
| Note: 1. Provide coordinated drawings that do not conflict each other. The provided new page one does not contain the design specifications and notes from the original page one. The new page one does not show all of the elevations. The page three show a different plumbing riser and also show the range which differs from the new page one. 5th Edition Florida building Code 107.2.1. J. Hindman 986-3784. | |||
| ELEC | HOLD | 08/30/2016 | 08/30/2016 |
| Note: 1) Calculated load shows 144amps for to a 100amp sub panel(B) being fed by a 200amp panel(A). 2) When utilizing NEC 2011 220.83B for existing units and adding the 144amp calculated load, the proposed calculations exceed the feeder amperage. -DC. Rewis 986-4736 | |||
| ZON | HOLD | 08/30/2016 | 08/31/2016 |
| Note: 1. Per LDC 4.01.01.A. - All accessory structures, other than fences and garages, shall be located behind the adjacent front or side street building footprint of the principal structure. 2. Primary structure appears to have a brick exterior and proposed accessory structure depicts siding. 3. Provide Single Family Dwelling Affidavit. This Affidavit must be signed by all persons on deed to property, and must be witnessed and notarized. | |||
| PLUM | COMPLETE | 08/30/2016 | 08/30/2016 |
| MECH | HOLD | 08/30/2016 | 08/30/2016 |
| Note: 1. Provide signature and license number of hvac contractor on hvac plan per FBC 5th ed. 107.2.1. 2. Energy performance level (EPL) display card on energy calculations shall be signed by the builder per FBCEC 5th ed. R401.3. 3. Directional orientation of the building shown on energy calculations shall match with the referenced North arrow on site plan per FBCEC 5th ed. R403.6.1. 4. Provide the manufacturer and model number of outdoor and indoor units per FBCEC 5th ed. R403.6.1. 5. Location of air handling unit shown on hvac plan does not match with floor plan. Coordinate for clarity per FBC 5th ed. 107.2.1. F.Reodica - 386-986-4734. | |||
| BLD | HOLD | 07/26/2016 | 07/27/2016 |
| Note: 1. Provide detail for the steel in the front porch footings. 5th ed. FBC 107.2.1. 2. Provide a roof truss layout with truss to wall connections per Florida Administrative Code 61G15-31.003. J Hindman | |||
| SW1 | COMPLETE | 07/26/2016 | 08/01/2016 |
| ZON | HOLD | 07/26/2016 | 07/28/2016 |
| Note: 1. Proposed structure does not meet the minimum street side setback dimension required for this zoning district. 2. Per LDC 13.03.01.A. Duplex residential dwelling units shall have the same architectural design, materials and colors for both sides. 3. 13.03.02.A.2 - Pitched roofs shall have a minimum slope of 5:12. 4. 13.03.03.C.1 - Windowless exterior walls, excluding garage doors, that face a public right-of-way are prohibited. 5. Provide landscape plan noting as per 11.03.02.2.b - Foundation shrubbery plantings are required for side street house exposure and accessory structures facing public rights of way. 6. Duplex units must meet minimum dimensional standards as per LDC table 3-3. 7. Accessory structures to single family residential dwellings are not allowed to have a separate kitchen facility. 8. Accessoty structures must have have the same exterior (materials and colors) as the primary structure. | |||
| ELEC | HOLD | 07/26/2016 | 07/27/2016 |
| Note: 1. Provide electrical load calculations for the house with the additional building's loads. 5th ed. FBC R E3602.2. 2. Provide GFCI receptacles at the kitchen counters spaced per 5th ed. FBC R E3901.4. 3. Provide a site specific Electrical riser diagram. 5th ed. FBC 107.2.1. 4. Identify the location and electrical specifications of the HVAC unit. 5th ed. FBC R E3702. J. Hindman 986-3784. | |||
| MECH | HOLD | 07/26/2016 | 07/28/2016 |
| Note: Provide energy calculations, hvac plan and hvac contractor per FBCEC 5th ed. R405/FBC 5th ed. 107.2.1/FS 489. F.Reodica -386-986-4734. | |||
| PLUM | HOLD | 07/26/2016 | 07/28/2016 |
| Note: Provide complete pipe sizes of fixture drains on sanitary riser diagram per FBC 5th ed. 107.2.1. F.Reodica - 386-986-4734. | |||
| ELEC | CANCEL | ||
| BLD | CANCEL | ||
| MECH | CANCEL | ||
| ZON | CANCEL |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | |
| Fees | Total Due: ¤40.00 | Total Paid: ¤0.00 |