I want to search for...

Permit #2016070844

Permit Details

Status: COED

Parcel Id: 16-11-31-1260-00000-0090
CONDITIONED SPACE: 2002 sqft
GARAGE: 456 sqft
SCREEN PORCH (SOLID ROOF) : 141 sqft
OPENED PORCH (WITH ROOF) : 25 sqft
Total Square Footage: 2624 sqft
Block: 00000
Subdivision: 2081 - Creekside Village at Grand Haven
Job Phone: 386-236-4133
Location Address: 3 CREEKSIDE CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/07/2016
NOC: RECORDED
Applicant name: FRANCIS D MORSE
Owner: INTERVEST CONSTRUCTION INC

Address

2379 BEVILLE ROAD

DAYTONA BEACH, FL 32119

Lot: 0090
Contracted Stated Job Value: ¤246,962.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INTERVEST CONSTRUCTION INC
Status Location Address State License Number Phone Fax
CANCEL

2379 BEVILLE RD

DAYTONA BEACH, FL 32119

CRC1329858 (Exp: 08/31/2018) 386-236-4133 386-763-7833

Sub Contractors

STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
CHARLES H KULP
Status Location Address State License Number Phone Fax
CANCEL

5401 ENERGY AIR CT

ORLANDO, FL 32810

CAC018270 (Exp: 08/31/2022) 407-886-3729 407-886-7580
GARY WAYNE EVERS
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 740106

ORANGE CITY, FL 32763

CFC050566 (Exp: 08/31/2026) 386-775-0909 386-775-0918
BARRY D MARTIN
Status Location Address State License Number Phone Fax
CANCEL

1650 N STATE STREET

Bunnell, FL 32110

CCC033728 (Exp: 08/31/2020) (386) 437-7700 (386)437-7701

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 03/06/2017 FINAL APPROVED DSPENCER
ROW - FINAL INSPECTION 03/03/2017 FINAL APPROVED GLALIMA
Note: INSPECTION PERFORMED ON MARCH 2th 2017 PASSED
BLD - BUILDING FINAL 03/03/2017 FINAL APPROVED LMILLER
ROW - FINAL APRON (AFTER POUR) 03/03/2017 APPROVED GLALIMA
Note: ON SITE YESTERDAY PASSED.
FINAL SURVEY (OFFICE USE ONLY) 03/02/2017 APPROVED FREODICA
Note: Field verified by G. Lalima.
ROW - FINAL APRON (AFTER POUR) 02/28/2017 APPROVED GLALIMA
ROW- PRE-APRON (PRE-POUR) 02/17/2017 APPROVED GLALIMA
Note: THIS IS A REINSPECTION
ROW- PRE-APRON (PRE-POUR) 02/13/2017 Disapproved -FEE REQUIRED GLALIMA
Note: NEW ROAD DAMAGE , FAILED , CHECK FORM BOARDS RIGHT SIDE COMING OUT OF GARAGE WILL RUN OFF
ELECTRIC - EARLY POWER 01/31/2017 APPROVED - AS NOTED LMILLER
Note: TALKED TO SUSAN AT FPL
GRAVITY SEWER TEST 01/10/2017 APPROVED DROCKWELL
U - SEWER TIE IN 01/10/2017 APPROVED JNICHOLS
Note: no inspection card onsite.
INSULATION 01/03/2017 APPROVED LMILLER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/29/2016 APPROVED CMINI
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 12/29/2016 APPROVED CMINI
ALL ROUGH 12/29/2016 APPROVED CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/28/2016 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION, missing strapping on mid block wall, rear porch
COLUMN POST/BEAM/TIE DOWN CONNECTOR 12/22/2016 CANCELLED BY INSPECTOR LMILLER
Note: wrong inspection cancelled per inspector
ELECTRIC-TUG 12/22/2016 APPROVED LMILLER
Note: THIS IS A REINSPECTION spoke to Dell at FPL
WALL SHEATHING 12/21/2016 APPROVED LMILLER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/20/2016 PARTIALLY APPROVED LMILLER
Note: SUPER WANTED A ROOF SHEATHENG ONLY AND CALLED THE WRONG INSPECTION IN, (ROOF SHEATHING PASSED, ROOF VALLEY METAL PASSED, WILL LOOK AT THE REST ON NEXT CALL IN)
ELECTRIC-TUG 12/12/2016 Disapproved -FEE REQUIRED LMILLER
Note: SECOND GROUND ROD NO LESS THAN 6 feet away E3608.4 if using only one rod, need to show resistance of 25 ohms or less on it.
TIE BEAM / LINTEL 12/01/2016 APPROVED CMINI
FOUND SURVEY APPROVED (OFFICE) 11/30/2016 APPROVED JHINDMAN
MONOLITHIC SLAB 11/16/2016 APPROVED LMILLER
PLUMBING 1ST ROUGH UNDERGROUND 11/14/2016 APPROVED CMINI
STEM WALL FOUNDATION 11/04/2016 APPROVED - AS NOTED LMILLER
Note: REMOVE LOOSE LEFT OVER CMU's PRIOR TO BACK FILLING (INSIDE OF STEM WALL)
STEM WALL FOUNDATION 10/05/2016 APPROVED LMILLER
Note: THIS IS A REINSPECTION
STEM WALL FOUNDATION 10/04/2016 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION NOT AS PROPOSED BY REVISION (MISSING FOOTING) (CIRCLED ON PLANS) CLEARANCE ON REBAR FROM EARTH 3 1D FBC R404.1.2.3.7.4
STEM WALL FOUNDATION 09/29/2016 CANCELLED BY APPLICANT LMILLER

Review History

Department Status Date In Date Out
SW1 COMPLETE 03/02/2017 03/02/2017
Note: Released By: FREODICA final s Field verified by G. Lalima.
PLFM COMPLETE 02/28/2017 03/01/2017
Note: The provided elevation certificate and survey demonstrate that the structure and accessory machinery falls outside the SFHA.
SW1 HOLD 02/28/2017 02/28/2017
Note: Held By: JHINDMAN Final survey provide positive drainage along the right side of the house from the rear to the front. J. Hindman 986-3784.
PLFM HOLD 12/02/2016 12/02/2016
Note: The following comments are associated with the elevation certificate review. The provided foundation survey details elevations for the residence and accessory machinery (AC Pad); the survey and surveyor comments reflects that these improvements are located in a “X” zone. In Section B8, depict only “X” zone and remove “AE” zone. For Section B9, replace 8’ with 8.0’ to ensure that one decimal place is depicted to be an accurate comparison with Section C elevations. In future submittals of elevation certificates, the signing and sealing professional shall utilize the elevation certificate form OMB No. 1660-0008 with expiration: November 30, 2016. A community is not allowed to take the July 31, 2015 after December 31, 2016.
SW1 COMPLETE 11/29/2016 11/30/2016
Note: Released By: JHINDMAN foundation s
BLD COMPLETE 09/26/2016 09/29/2016
ZON COMPLETE 09/26/2016 09/27/2016
PLUM COMPLETE 08/30/2016 08/30/2016
ZON COMPLETE 08/24/2016 08/25/2016
PLFM COMPLETE 08/24/2016 08/24/2016
Note: Informational: Staff recognizes that the EC reflects the proposed structure and accessory mechanical solely rests in an “X” zone. No additional ECs will be required for the subject project. Please note that on future EC submittals Section B8 should reflect one zone which respects the more restrictive zone that affects the structure and/or accessory mechanical. Within Section D, additional comments can be provided to respect that multiple zone designations exist.
PLUM HOLD 08/24/2016 08/25/2016
Note: Repeat comment. Provide vent either at the shower or tub at owner's bathroom to comply with FBCR 5th ed. P3108. F.Reodica-386-986-4734. Note: Not more than one wet-vented fixture drain shall discharge upstream of the dry-vented fixture drain connection per FBC 5th ed. P3108.2.1.
SW1 COMPLETE 08/24/2016 08/24/2016
PLFM HOLD 07/29/2016 08/01/2016
Note: According to City of Palm Coast mapping resources, the subject property is located within an AE zone which is a Special Flood Hazard Area. Provide an elevation certificate to verify the proposed elevations of the improvements. The signing and sealing professional shall utilize the elevation certificate form OMB No. 1660-0008 with expiration: November 30, 2016. Elevation certificates will be required at three (3) stages of construction for the nature center (1. Preconstruction 2. Foundation 3. Vertical construction).
BLD COMPLETE 07/27/2016 08/01/2016
ELEC COMPLETE 07/27/2016 08/02/2016
ENGIN1 COMPLETE 07/27/2016 07/28/2016
Note: Creekside Drive is designed with curb and gutter; therefore, a swale plan is not required.
MECH COMPLETE 07/27/2016 08/01/2016
PLUM HOLD 07/27/2016 08/01/2016
Note: Provide vent either at the shower or tub to comply with FBCR 5th ed. P3108. F.Reodica-386-986-4734.
SW1 HOLD 07/27/2016 08/02/2016
Note: West side of residence does not depict even flow through easements to swale. -DC. Rewis 986-4736
UD1 COMPLETE 07/27/2016 07/28/2016
ZON HOLD 07/27/2016 07/29/2016
Note: 1. Site plan must depict total square footage of lot. 2. Site plan must depict rear setback dimension.
URB COMPLETE 07/27/2016 07/28/2016

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 03/06/2017
REINSPECTION FEE ¤40.00 03/06/2017
REINSPECTION FEE ¤40.00 03/06/2017
REINSPECTION FEE ¤40.00 03/06/2017
REVISION ¤40.00 03/06/2017
SITE PLAN 20 ¤20.00 09/07/2016
SURCHARGE FS 533.721 ¤18.86 09/07/2016
SURCHARGE - FS 468.631 ¤18.86 09/07/2016
STORM WATER PERMIT FEES ¤80.00 09/07/2016
3% TRANS IMPACT FEE CREDIT (¤93.74) 09/07/2016
NEW RESIDENTIAL INSPECTIONS ¤494.00 09/07/2016
ADMIN FEE ¤20.00 09/07/2016
ELECTRIC FEE ¤208.20 09/07/2016
3% FIRE IMPACT FEE CREDIT (¤6.43) 09/07/2016
IMPACT FEE FIRE NONRESIDENTIAL ¤214.29 09/07/2016
IMPACT FEE PARKS ¤849.24 09/07/2016
IMPACT FEE SCHOOL ¤3,600.00 09/07/2016
IMPACT FEE TRANSPORTATION ¤3,124.67 09/07/2016
MECHANICAL FEE ¤208.20 09/07/2016
3% PARKS IMPACT FEE CREDIT (¤25.48) 09/07/2016
PLAN CHECK FEE ¤98.80 09/07/2016
PLUMBING FEE ¤208.20 09/07/2016
Fees Total Due: ¤0.00 Total Paid: ¤9,237.67