Permit #2016070844
Permit Details
Status: COED
| Parcel Id: 16-11-31-1260-00000-0090 |
| CONDITIONED SPACE: 2002 sqft |
| GARAGE: 456 sqft |
| SCREEN PORCH (SOLID ROOF) : 141 sqft |
| OPENED PORCH (WITH ROOF) : 25 sqft |
| Total Square Footage: 2624 sqft |
| Block: 00000 |
| Subdivision: 2081 - Creekside Village at Grand Haven |
| Job Phone: 386-236-4133 |
| Location Address: 3 CREEKSIDE CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/07/2016 |
| NOC: RECORDED |
| Applicant name: FRANCIS D MORSE |
| Owner: INTERVEST CONSTRUCTION INC |
|
Address 2379 BEVILLE ROAD DAYTONA BEACH, FL 32119 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤246,962.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
INTERVEST CONSTRUCTION INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2379 BEVILLE RD DAYTONA BEACH, FL 32119 |
CRC1329858 (Exp: 08/31/2018) | 386-236-4133 | 386-763-7833 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
CHARLES H KULP
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
5401 ENERGY AIR CT ORLANDO, FL 32810 |
CAC018270 (Exp: 08/31/2022) | 407-886-3729 | 407-886-7580 |
GARY WAYNE EVERS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 740106 ORANGE CITY, FL 32763 |
CFC050566 (Exp: 08/31/2026) | 386-775-0909 | 386-775-0918 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 03/06/2017 | FINAL APPROVED | DSPENCER |
| ROW - FINAL INSPECTION | 03/03/2017 | FINAL APPROVED | GLALIMA |
| Note: INSPECTION PERFORMED ON MARCH 2th 2017 PASSED | |||
| BLD - BUILDING FINAL | 03/03/2017 | FINAL APPROVED | LMILLER |
| ROW - FINAL APRON (AFTER POUR) | 03/03/2017 | APPROVED | GLALIMA |
| Note: ON SITE YESTERDAY PASSED. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 03/02/2017 | APPROVED | FREODICA |
| Note: Field verified by G. Lalima. | |||
| ROW - FINAL APRON (AFTER POUR) | 02/28/2017 | APPROVED | GLALIMA |
| ROW- PRE-APRON (PRE-POUR) | 02/17/2017 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| ROW- PRE-APRON (PRE-POUR) | 02/13/2017 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: NEW ROAD DAMAGE , FAILED , CHECK FORM BOARDS RIGHT SIDE COMING OUT OF GARAGE WILL RUN OFF | |||
| ELECTRIC - EARLY POWER | 01/31/2017 | APPROVED - AS NOTED | LMILLER |
| Note: TALKED TO SUSAN AT FPL | |||
| GRAVITY SEWER TEST | 01/10/2017 | APPROVED | DROCKWELL |
| U - SEWER TIE IN | 01/10/2017 | APPROVED | JNICHOLS |
| Note: no inspection card onsite. | |||
| INSULATION | 01/03/2017 | APPROVED | LMILLER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/29/2016 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 12/29/2016 | APPROVED | CMINI |
| ALL ROUGH | 12/29/2016 | APPROVED | CMINI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/28/2016 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION, missing strapping on mid block wall, rear porch | |||
| COLUMN POST/BEAM/TIE DOWN CONNECTOR | 12/22/2016 | CANCELLED BY INSPECTOR | LMILLER |
| Note: wrong inspection cancelled per inspector | |||
| ELECTRIC-TUG | 12/22/2016 | APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION spoke to Dell at FPL | |||
| WALL SHEATHING | 12/21/2016 | APPROVED | LMILLER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/20/2016 | PARTIALLY APPROVED | LMILLER |
| Note: SUPER WANTED A ROOF SHEATHENG ONLY AND CALLED THE WRONG INSPECTION IN, (ROOF SHEATHING PASSED, ROOF VALLEY METAL PASSED, WILL LOOK AT THE REST ON NEXT CALL IN) | |||
| ELECTRIC-TUG | 12/12/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: SECOND GROUND ROD NO LESS THAN 6 feet away E3608.4 if using only one rod, need to show resistance of 25 ohms or less on it. | |||
| TIE BEAM / LINTEL | 12/01/2016 | APPROVED | CMINI |
| FOUND SURVEY APPROVED (OFFICE) | 11/30/2016 | APPROVED | JHINDMAN |
| MONOLITHIC SLAB | 11/16/2016 | APPROVED | LMILLER |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/14/2016 | APPROVED | CMINI |
| STEM WALL FOUNDATION | 11/04/2016 | APPROVED - AS NOTED | LMILLER |
| Note: REMOVE LOOSE LEFT OVER CMU's PRIOR TO BACK FILLING (INSIDE OF STEM WALL) | |||
| STEM WALL FOUNDATION | 10/05/2016 | APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION | |||
| STEM WALL FOUNDATION | 10/04/2016 | Disapproved -FEE REQUIRED | LMILLER |
| Note: THIS IS A REINSPECTION NOT AS PROPOSED BY REVISION (MISSING FOOTING) (CIRCLED ON PLANS) CLEARANCE ON REBAR FROM EARTH 3 1D FBC R404.1.2.3.7.4 | |||
| STEM WALL FOUNDATION | 09/29/2016 | CANCELLED BY APPLICANT | LMILLER |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 03/02/2017 | 03/02/2017 |
| Note: Released By: FREODICA final s Field verified by G. Lalima. | |||
| PLFM | COMPLETE | 02/28/2017 | 03/01/2017 |
| Note: The provided elevation certificate and survey demonstrate that the structure and accessory machinery falls outside the SFHA. | |||
| SW1 | HOLD | 02/28/2017 | 02/28/2017 |
| Note: Held By: JHINDMAN Final survey provide positive drainage along the right side of the house from the rear to the front. J. Hindman 986-3784. | |||
| PLFM | HOLD | 12/02/2016 | 12/02/2016 |
| Note: The following comments are associated with the elevation certificate review. The provided foundation survey details elevations for the residence and accessory machinery (AC Pad); the survey and surveyor comments reflects that these improvements are located in a “X” zone. In Section B8, depict only “X” zone and remove “AE” zone. For Section B9, replace 8’ with 8.0’ to ensure that one decimal place is depicted to be an accurate comparison with Section C elevations. In future submittals of elevation certificates, the signing and sealing professional shall utilize the elevation certificate form OMB No. 1660-0008 with expiration: November 30, 2016. A community is not allowed to take the July 31, 2015 after December 31, 2016. | |||
| SW1 | COMPLETE | 11/29/2016 | 11/30/2016 |
| Note: Released By: JHINDMAN foundation s | |||
| BLD | COMPLETE | 09/26/2016 | 09/29/2016 |
| ZON | COMPLETE | 09/26/2016 | 09/27/2016 |
| PLUM | COMPLETE | 08/30/2016 | 08/30/2016 |
| ZON | COMPLETE | 08/24/2016 | 08/25/2016 |
| PLFM | COMPLETE | 08/24/2016 | 08/24/2016 |
| Note: Informational: Staff recognizes that the EC reflects the proposed structure and accessory mechanical solely rests in an “X” zone. No additional ECs will be required for the subject project. Please note that on future EC submittals Section B8 should reflect one zone which respects the more restrictive zone that affects the structure and/or accessory mechanical. Within Section D, additional comments can be provided to respect that multiple zone designations exist. | |||
| PLUM | HOLD | 08/24/2016 | 08/25/2016 |
| Note: Repeat comment. Provide vent either at the shower or tub at owner's bathroom to comply with FBCR 5th ed. P3108. F.Reodica-386-986-4734. Note: Not more than one wet-vented fixture drain shall discharge upstream of the dry-vented fixture drain connection per FBC 5th ed. P3108.2.1. | |||
| SW1 | COMPLETE | 08/24/2016 | 08/24/2016 |
| PLFM | HOLD | 07/29/2016 | 08/01/2016 |
| Note: According to City of Palm Coast mapping resources, the subject property is located within an AE zone which is a Special Flood Hazard Area. Provide an elevation certificate to verify the proposed elevations of the improvements. The signing and sealing professional shall utilize the elevation certificate form OMB No. 1660-0008 with expiration: November 30, 2016. Elevation certificates will be required at three (3) stages of construction for the nature center (1. Preconstruction 2. Foundation 3. Vertical construction). | |||
| BLD | COMPLETE | 07/27/2016 | 08/01/2016 |
| ELEC | COMPLETE | 07/27/2016 | 08/02/2016 |
| ENGIN1 | COMPLETE | 07/27/2016 | 07/28/2016 |
| Note: Creekside Drive is designed with curb and gutter; therefore, a swale plan is not required. | |||
| MECH | COMPLETE | 07/27/2016 | 08/01/2016 |
| PLUM | HOLD | 07/27/2016 | 08/01/2016 |
| Note: Provide vent either at the shower or tub to comply with FBCR 5th ed. P3108. F.Reodica-386-986-4734. | |||
| SW1 | HOLD | 07/27/2016 | 08/02/2016 |
| Note: West side of residence does not depict even flow through easements to swale. -DC. Rewis 986-4736 | |||
| UD1 | COMPLETE | 07/27/2016 | 07/28/2016 |
| ZON | HOLD | 07/27/2016 | 07/29/2016 |
| Note: 1. Site plan must depict total square footage of lot. 2. Site plan must depict rear setback dimension. | |||
| URB | COMPLETE | 07/27/2016 | 07/28/2016 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 03/06/2017 |
| REINSPECTION FEE | ¤40.00 | 03/06/2017 |
| REINSPECTION FEE | ¤40.00 | 03/06/2017 |
| REINSPECTION FEE | ¤40.00 | 03/06/2017 |
| REVISION | ¤40.00 | 03/06/2017 |
| SITE PLAN 20 | ¤20.00 | 09/07/2016 |
| SURCHARGE FS 533.721 | ¤18.86 | 09/07/2016 |
| SURCHARGE - FS 468.631 | ¤18.86 | 09/07/2016 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/07/2016 |
| 3% TRANS IMPACT FEE CREDIT | (¤93.74) | 09/07/2016 |
| NEW RESIDENTIAL INSPECTIONS | ¤494.00 | 09/07/2016 |
| ADMIN FEE | ¤20.00 | 09/07/2016 |
| ELECTRIC FEE | ¤208.20 | 09/07/2016 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.43) | 09/07/2016 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤214.29 | 09/07/2016 |
| IMPACT FEE PARKS | ¤849.24 | 09/07/2016 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 09/07/2016 |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | 09/07/2016 |
| MECHANICAL FEE | ¤208.20 | 09/07/2016 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 09/07/2016 |
| PLAN CHECK FEE | ¤98.80 | 09/07/2016 |
| PLUMBING FEE | ¤208.20 | 09/07/2016 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,237.67 |