Permit Details

Status: COED

Parcel Id: 07-11-31-7022-00270-0500
CONDITIONED SPACE: 1985 sqft
GARAGE: 750 sqft
OPENED PORCH (WITH ROOF) : 288 sqft
OPENED PORCH (WITH ROOF) : 32 sqft
Total Square Footage: 3055 sqft
Block: 00270
Subdivision: 2217 - SECTION 22-WYNNFIELD
Job Phone: 386-931-1725
Location Address: 4 WESTROSE PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/30/2016
NOC: RECORDED
Applicant name: JOSEPH ALEIXO PORTAL
Owner: SWEETWATER CUSTOM HOMES

Address

1105 LAMBERT AVENUE

FLAGLER BEACH, FL 32136

Lot: 0500
Contracted Stated Job Value: ¤165,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SWEETWATER CUSTOM HOMES INC.
Status Location Address State License Number Phone Fax
INACTIVE

1105 LAMBERT AVENUE

FLAGLER BEACH, FL 32136

CBC1252965 (Exp: 08/31/2024) 386-931-1725 386-439-4676

Sub Contractors

RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 1963

BUNNELL, FL 32110

ES12001217 (Exp: 08/31/2026) 386-437-0607 386-437-1847
JOHN ROBERT BLEVINS JR
Status Location Address State License Number Phone Fax
ACTIVE

17 PORWYN LANE

PALM COAST, FL 32164

CAC1816125 (Exp: 08/31/2026) 386-585-8283 386-263-2096
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JAMES ALLEN TAYLOR
Status Location Address State License Number Phone Fax
CANCEL

265 TYMBER CREEK ROAD

ORMOND BEACH, FL 32174

CCC1326819 (Exp: 08/31/2022) (386)290-0281 (386)673-5216

Inspection History

Type Request Date Result Inspector
PLUMBING 1ST ROUGH UNDERGROUND 11/09/2018 CANCELLED BY APPLICANT WEB
BLD - BUILDING FINAL 11/09/2018 FINAL APPROVED JCOLASANTI
U -UTILITY RESIDENTIAL FINAL 11/09/2018 FINAL APPROVED MBACON
U -UTILITY RESIDENTIAL FINAL 11/08/2018 Disapproved -FEE REQUIRED LFITZGERALD
Note: the flush mount sewer clean out for the sewer tap not observable
ROW - FINAL INSPECTION 11/08/2018 FINAL APPROVED KHOWELL
BLD - BUILDING FINAL 11/08/2018 Disapproved -FEE REQUIRED JCOLASANTI
Note: NEED TO HAVE ARC SHIELDS WHERE THERE IS MORE THAN 1/4" SPACE AT COMBUSTABLES ...need water hammer at sink....need claear opening to shower of 22" P2101...need 3' clearance for disconnect at AC unit
U -UTILITY RESIDENTIAL FINAL 11/05/2018 CANCELLED BY APPLICANT WEB
ROW - FINAL APRON (AFTER POUR) 10/08/2018 APPROVED KHOWELL
ROW - FINAL APRON (AFTER POUR) 09/25/2018 CANCELLED BY APPLICANT KHOWELL
ROW - FINAL INSPECTION 09/25/2018 CANCELLED BY APPLICANT KHOWELL
FINAL SURVEY (OFFICE USE ONLY) 05/22/2018 APPROVED DREWIS
ELECTRIC - EARLY POWER 03/05/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 1:20
PRE-APRON (PRE-POUR/DRIVEWAY) 03/05/2018 APPROVED RGROSS
Note: READY TO POUR
U - SEWER TIE IN 12/22/2017 APPROVED LFITZGERALD
GRAVITY SEWER TEST 12/22/2017 APPROVED JGIBSON
TUB SET 11/17/2017 APPROVED JGIBSON
INSULATION 08/01/2017 APPROVED JCOLASANTI
ELECTRIC TEMP POLE 07/17/2017 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED TEMP POLE POWER 2:30
ELECTRIC - EARLY POWER 07/14/2017 Disapproved -FEE REQUIRED RMARTIN
Note: THIS HOUSE IS NOT READY FOR EARLY POWER...... MAYBE WRONG INSPECTION CALLED IN...... TEMP POLE?
ALL ROUGH 07/12/2017 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
ALL ROUGH 06/30/2017 Disapproved -FEE REQUIRED JCOLASANTI
Note: dryer exhust needs to be sealed with mastic at roof ..FBC.. M1601.4.1.7....attach exhaust vent at guest bath....attach screws at arch window.....( note need tub set inspection)
LATH/BRICK/ WATER BARRIER 06/26/2017 APPROVED JCOLASANTI
ROOF VALLEY & METAL 05/31/2017 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
ROOF VALLEY & METAL 05/24/2017 Disapproved -FEE REQUIRED JCOLASANTI
Note: roof L flashing needs to be set in approved roof cement FBC905
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/03/2017 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/25/2017 Disapproved -FEE REQUIRED CMINI
Note: NEED APPROVED ENGINEERING SUBMITTED AND REVIEWED FROM B.D. AND BACK ON PROPERTY FOR ALTERD TRUSSES. NEED CONTINUOUS LOAD PATH ON KNEE WALL AT MASTER BATH EXTERIOR WALL. CORNER JACKS AT FRONT ENTRY MISSING STRAPS. TRUSS T-38 STRAP NEEDS CORRECTION
TIE BEAM / LINTEL 02/08/2017 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 02/02/2017 Disapproved -FEE REQUIRED LMILLER
Note: 1. CHANGES IN HEIGHT R609.2.5 AND FIGURE 609.2.5 UPPER AND LOWER BONDBEAMS MUST BE CONTINUOUSE, HAVE VERTICLE STEEL AND GROUTED SOLID AND MUST HAVE A FILLED CELL UNDER EACH CELL ADJOINING CHANGES IN HEIGHT (MISSING) 2. CLEANOUT OPENINGS 26. R606.13.7, and 609.1.5 CLEANOUT OPENINGS SHALL BE PROVIDED, MINIMUM 3 inch OPENING (MISSING AT CHANGES IN HEIGHT) (ALL CIRCLED ON FOUNDATION PAGE)
FOUND SURVEY APPROVED (OFFICE) 01/27/2017 APPROVED FREODICA
MONOLITHIC SLAB 12/28/2016 APPROVED - AS NOTED JCOLASANTI
Note: need compaction test sticker in box by next inspection.
PLUMBING 1ST ROUGH UNDERGROUND 12/02/2016 APPROVED JCOLASANTI

Review History

Department Status Date In Date Out
SW1 COMPLETE 05/21/2018 05/22/2018
Note: Released By: DREWIS final s
SW1 COMPLETE 01/26/2017 01/27/2017
Note: Released By: FREODICA foundation s
ZON COMPLETE 08/31/2016 08/31/2016
ZON HOLD 08/11/2016 08/12/2016
Note: REPEAT COMMENTS: Please clarify the following inconsistencies: The blueprints depict the A/C pad and equipment differently than the site plan and the landscape plan. All concrete pads must be shown (with dimensions) and all documents must match. Also please note that the landscape plan must show screening for the A/C equipment.
MECH COMPLETE 08/11/2016 08/12/2016
ENGIN1 COMPLETE 08/11/2016 08/12/2016
BLD COMPLETE 08/11/2016 08/12/2016
ELEC COMPLETE 08/11/2016 08/12/2016
BLD HOLD 08/01/2016 08/03/2016
Note: 1. Provide plans designed per the 5th edition of the Florida building code. J. Hindman 986-3784
ELEC HOLD 08/01/2016 08/03/2016
Note: 1. Provide plans designed to the 2011 National Electric code. J. Hindman 986-3784.
ENGIN1 HOLD 08/01/2016 08/02/2016
Note: The centerline of cul-de-sac elevation provided and labeled as TBM is incorrect. Review this elevation along with the benchmark and provide a revised site plan including the correct information.
MECH HOLD 08/01/2016 08/02/2016
Note: Energy performance level (EPL) display card shall be signed by the builder per FBCEC 5th ed. R401.3. F.Reodica -386-986-4734.
PLUM COMPLETE 08/01/2016 08/02/2016
SW1 COMPLETE 08/01/2016 08/04/2016
UD1 COMPLETE 08/01/2016 08/02/2016
ZON HOLD 08/01/2016 08/02/2016
Note: Please clarify the following inconsistencies: The blueprints depict the A/C pad and equipment differently than the site plan and the landscape plan. All concrete pads must be shown (with dimensions) and all documents must match. Also please note that the landscape plan must show screening for the A/C equipment.
URB COMPLETE 08/01/2016 08/01/2016

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 11/09/2018
REINSPECTION FEE ¤40.00 11/09/2018
REINSPECTION FEE ¤40.00 11/09/2018
REINSPECTION FEE ¤40.00 11/09/2018
REINSPECTION FEE ¤40.00 11/09/2018
REINSPECTION FEE ¤40.00 11/09/2018
NEW RESIDENTIAL INSPECTIONS ¤528.00 09/30/2016
SITE PLAN 20 ¤20.00 09/30/2016
SURCHARGE FS 533.721 ¤19.93 09/30/2016
SURCHARGE - FS 468.631 ¤19.93 09/30/2016
STORM WATER PERMIT FEES ¤80.00 09/30/2016
3% TRANS IMPACT FEE CREDIT (¤93.74) 09/30/2016
ADMIN FEE ¤20.00 09/30/2016
ELECTRIC FEE ¤218.40 09/30/2016
3% FIRE IMPACT FEE CREDIT (¤6.43) 09/30/2016
IMPACT FEE FIRE NONRESIDENTIAL ¤214.29 09/30/2016
IMPACT FEE PARKS ¤849.24 09/30/2016
IMPACT FEE SCHOOL ¤3,600.00 09/30/2016
IMPACT FEE TRANSPORTATION ¤3,124.67 09/30/2016
MECHANICAL FEE ¤218.40 09/30/2016
3% PARKS IMPACT FEE CREDIT (¤25.48) 09/30/2016
PLAN CHECK FEE ¤105.60 09/30/2016
PLUMBING FEE ¤218.40 09/30/2016
Fees Total Due: ¤0.00 Total Paid: ¤9,351.21