I want to search for...

Permit #2016080366

Permit Details

Status: COED

Parcel Id: 07-11-31-7019-00480-0070
CONDITIONED SPACE: 2070 sqft
GARAGE: 438 sqft
OPENED PORCH (WITH ROOF) : 215 sqft
OPENED PORCH (WITH ROOF) : 61 sqft
Total Square Footage: 2784 sqft
Block: 00480
Subdivision: 2214 - SECTION 19-WYNNFIELD
Job Phone: (386)446-5161
Location Address: 1 WILKSBORO PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/24/2016
NOC: RECORDED
Applicant name: HUGO A CAMACHO
Owner: TAILLEFER, JEAN & EUGENIE BEASON

Address

3547 LACONIA AVE

BRONX, NY 10469

Lot: 0070
Contracted Stated Job Value: ¤235,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

IDEAL HOMES AT PALM COAST, INC.
Status Location Address State License Number Phone Fax
INACTIVE

PO BOX 353639

PALM COAST, FL 32137

CBC1250774 (Exp: 08/31/2026) (386)446-5161 (386)447-0238

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
THOMAS A REGULA
Status Location Address State License Number Phone Fax
INACTIVE

11320 PHILLIPS PKWY DRIVE E

JACKSONVILLE, FL 32256

CMC1250075 (Exp: 08/31/2026) 904-278-0339 904-278-0366
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JOANNA S REELEY
Status Location Address State License Number Phone
INACTIVE

2 MARKET PLACE D

PALM COAST, FL 32137

CCC1327485 (Exp: 08/31/2020) 386-445-7945

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 04/26/2017 FINAL APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION
U -UTILITY RESIDENTIAL FINAL 04/25/2017 Disapproved -FEE REQUIRED LFITZGERALD
Note: sewer cleanout cap required to be a flush mount type(not a exposed square nut),also even with sod grade.
BLD - BUILDING FINAL 04/24/2017 FINAL APPROVED CMINI
Note: THIS IS A REINSPECTION
ROW - FINAL INSPECTION 04/20/2017 APPROVED RGROSS
Note: APPROVED
BLD - BUILDING FINAL 04/20/2017 Disapproved -FEE REQUIRED JCOLASANTI
Note: WHIRLPOOL PUMPS BONDING 680.62 (B) METAL PARTS OF ELECTRICAL EQUIPMENT ASSOCIATED WITH TUB WATER CIRCULATING SYSTEM INCLUDING PUMP MOTORS SHALL BE BONDED TOGETHER.....need to hace weatherproof covers on exterior receptical in back porch.....GFI in master bathroom not tripping
ROW - FINAL APRON (AFTER POUR) 04/20/2017 APPROVED RGROSS
Note: APPROVED
FINAL SURVEY (OFFICE USE ONLY) 04/19/2017 APPROVED JHINDMAN
ROW- PRE-APRON (PRE-POUR) 02/13/2017 APPROVED CTROHA
Note: THIS IS A REINSPECTION ready for pavers
ROW- PRE-APRON (PRE-POUR) 02/08/2017 PARTIALLY APPROVED RGROSS
Note: APPROVED FOR CONCRETE OVER PIPE ONLY. PAVER DRIVEWAY
ELECTRIC - EARLY POWER 02/01/2017 APPROVED - AS NOTED CMINI
Note: CALLED SUSAN FPL
GRAVITY SEWER TEST 01/26/2017 APPROVED JCOLASANTI
U - SEWER TIE IN 01/26/2017 APPROVED JNICHOLS
LATH/BRICK/ WATER BARRIER 01/10/2017 FINAL APPROVED LMILLER
INSULATION 12/27/2016 APPROVED JCOLASANTI
ALL ROUGH 12/21/2016 APPROVED - AS NOTED JCOLASANTI
Note: THIS IS A REINSPECTION need to fill pipe with water for dwv 10' test will check at insulation
ALL ROUGH 12/20/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: TEST ON DWV AND WATER PIPPING TEST PIPE SHALL BE FILLED WITH WATER TO A POINT NOT LESS THAN 10 19AND HELD UNDER TEST FOR A PERIOD OF 15 MIN. FPC .312 fbc 2503.5.1..Required outlets and spacing of outlets. NEC 2008 210.52 (master bedroom wall entering bathroom)...METAL BOXES SHALL BE GROUNDED NEC.314.4 box by door to rear porch......need to phase out hot WHITE wires in panel.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/12/2016 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/30/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: CONTINUOUS LOAD PATH FOR UPLIFT RESISTANCE FBC.. 802.1.9.....missing strap rear bathroom corner....straps need nailing (all marked on plans)
TIE BEAM / LINTEL 10/21/2016 APPROVED JCOLASANTI
FOUND SURVEY APPROVED (OFFICE) 10/14/2016 APPROVED FREODICA
MONOLITHIC SLAB 09/27/2016 APPROVED - AS NOTED JCOLASANTI
Note: THIS IS A REINSPECTION need to have compaction test sticker in box by next inspection, pour at your own risk
MONOLITHIC SLAB 09/26/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: internal footing not to plan, detail F2
PLUMBING 1ST ROUGH UNDERGROUND 09/19/2016 APPROVED JCOLASANTI

Review History

Department Status Date In Date Out
ZON COMPLETE 01/31/2017 01/31/2017
ENGIN1 COMPLETE 01/10/2017 01/31/2017
Note: Use revised swale plan dated 1-31-17
SW1 COMPLETE 01/10/2017 01/18/2017
UD1 COMPLETE 01/10/2017 01/12/2017
Note: All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON HOLD 01/10/2017 01/11/2017
Note: R.O.W. agreement must be signed by all people on the deed
BLD COMPLETE 11/17/2016 11/29/2016
SW1 COMPLETE 10/13/2016 10/14/2016
Note: Released By: FREODICA FOUNDATION S
BLD COMPLETE 09/01/2016 09/01/2016
URB COMPLETE 08/19/2016 08/23/2016
MECH COMPLETE 08/19/2016 08/19/2016
ENGIN1 COMPLETE 08/19/2016 08/23/2016
BLD COMPLETE 08/11/2016 08/12/2016
ELEC COMPLETE 08/11/2016 08/12/2016
ENGIN1 HOLD 08/11/2016 08/17/2016
Note: The benchmark on the site plan does not match our surveyor's measurements. The centerline of road elevations do match the as-built values; therefore, it is likely a transposing error with the benchmark values. Please review the benchmark data and revise the benchmark value as necessary.
MECH HOLD 08/11/2016 08/12/2016
Note: Directional orientation of the building shown in energy calculations does not match with site plan. Coordinate to comply with FBCEC 5th ed. R403.6.1. F.Reodica - 386-986-4734.
PLUM COMPLETE 08/11/2016 08/12/2016
SW1 COMPLETE 08/11/2016 08/12/2016
UD1 COMPLETE 08/11/2016 08/15/2016
ZON COMPLETE 08/11/2016 08/15/2016
URB HOLD 08/11/2016 08/12/2016
Note: LDC requires 1 shade tree planted front with 15ft setback from overhead power lines. can trade left rear shade tree for left front understory tree.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
RECORDING FEE REIMBURSE DOC ¤52.50 04/28/2017
REINSPECTION FEE ¤40.00 04/28/2017
REINSPECTION FEE ¤40.00 04/28/2017
REINSPECTION FEE ¤40.00 04/28/2017
REINSPECTION FEE ¤40.00 04/28/2017
REINSPECTION FEE ¤40.00 04/28/2017
REVISION ¤40.00 04/28/2017
REVISION ¤40.00 04/28/2017
SITE PLAN 20 ¤20.00 08/24/2016
SURCHARGE FS 533.721 ¤19.62 08/24/2016
SURCHARGE - FS 468.631 ¤19.62 08/24/2016
STORM WATER PERMIT FEES ¤80.00 08/24/2016
3% TRANS IMPACT FEE CREDIT (¤93.74) 08/24/2016
NEW RESIDENTIAL INSPECTIONS ¤518.00 08/24/2016
IMPACT FEE TRANSPORTATION ¤3,124.67 08/24/2016
MECHANICAL FEE ¤215.40 08/24/2016
3% PARKS IMPACT FEE CREDIT (¤25.48) 08/24/2016
PLAN CHECK FEE ¤103.60 08/24/2016
PLUMBING FEE ¤215.40 08/24/2016
ADMIN FEE ¤20.00 08/24/2016
ELECTRIC FEE ¤215.40 08/24/2016
3% FIRE IMPACT FEE CREDIT (¤6.43) 08/24/2016
IMPACT FEE FIRE NONRESIDENTIAL ¤214.29 08/24/2016
IMPACT FEE PARKS ¤849.24 08/24/2016
IMPACT FEE SCHOOL ¤3,600.00 08/24/2016
Fees Total Due: ¤0.00 Total Paid: ¤9,422.09