I want to search for...

Permit #2016080871

Permit Details

Status: COED

Parcel Id: 07-11-31-1090-00000-00B0
Block: 00000
Subdivision: 1228 - SOUTHWEST QUADRANT
Job Phone: 386-447-1402
Location Address: 160 CYPRESS POINT PKWY
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 11/23/2016
NOC: Unknown
Applicant name: RONALD ERIC PHILLIPS
Owner: CYPRESS POINT 160 LLC

Address

3920 RCA BOULEVARD

PALM BEACH GARDENS, FL 33410

Address

SUITE 2002

PALM BEACH GARDENS, FL 33410

Lot: 00B0
Contracted Stated Job Value: ¤2,000.00
Job Description: C 105 - PLUMBING WORK FOR SERVICE & MAIN SINKS "MARIO'S BAKERY & COFFEE SHOP"
Type: CN

Contractor

PHILLIPS COASTAL CONSTRUCTION, INC
Status Location Address State License Number Phone
CANCEL

58 BUTTERFIELD DRIVE

PALM COAST, FL 32137

CGC1506412 (Exp: 08/31/2024) 386-447-1402

Sub Contractors

HEATH EDWARD SANFORD
Status Location Address State License Number Phone Fax
ACTIVE

1351 HAZELNUT ST

BUNNELL, FL 32110

CFC1427527 (Exp: 08/31/2026) 386-445-2532 386-445-5575

Inspection History

Type Request Date Result Inspector
U - UTILITY COMMERCIAL FINAL 01/06/2017 FINAL APPROVED JNICHOLS
BUILDING FINAL 01/05/2017 FINAL APPROVED CMINI
PLUMBING FINAL 01/05/2017 APPROVED CMINI
ELECTRIC FINAL 01/05/2017 FINAL APPROVED RMARTIN
ABOVE CEILING 12/19/2016 APPROVED CMINI

Review History

Department Status Date In Date Out
ELEC COMPLETE 12/21/2016 12/27/2016
BLD COMPLETE 11/17/2016 11/22/2016
PLUM COMPLETE 11/17/2016 11/22/2016
ELEC COMPLETE 11/07/2016 11/07/2016
BLD HOLD 11/07/2016 11/08/2016
Note: 1. Based on the occupant load of 47 this plan meets the exception for an Assembly-2 occupancy and can be classified as a Business occupancy. The plans need to reflect the correct occupancy as an A-2 occupancy will not work for the exit requirements as you cannot exit thru a kitchen. 5th edition Florida building code 303.1.1 and 1014.2. J. Hindman 986-3784.2nd request. (Remove exit sign at kitchen and change Occupancy to Business exception.).
PLUM HOLD 11/07/2016 11/08/2016
Note: 1. Provide domestic water riser diagram (hot and cold) per FBC 5th ed. 107.3.5 as previously requested. 2. Revise the occupancy classification to business and occupant load calculation FBC 5th ed. 302 3. Provide vent for the mop sink per FBCP 910.1. F.Reodica-386-986-4734.
MECH COMPLETE 11/07/2016 11/08/2016
Note: No change in hvac sytem.
MECH HOLD 10/19/2016 10/19/2016
Note: Provide hvac plan and hvac contractor per FS 489. The addition of wall and door with full height up to the existing roof system between kitchen area and customer area create an unbalance return air to the hvac unit per FBCM 5th ed. 601.5. F.Reodica - 386-986-4734.
ELEC HOLD 10/18/2016 10/19/2016
Note: 1. Provide electrical load calculations per 2011 NEC art. 220. J. Hindman 986-3784.
BLD HOLD 10/18/2016 10/19/2016
Note: 1. Based on the occupant load of 47 this plan meets the exception for an Assembly-2 occupancy and can be classified as a Business occupancy. The plans need to reflect the correct occupancy as an A-2 occupancy will not work for the exit requirements as you cannot exit thru a kitchen. 5th edition Florida building code 303.1.1 and 1014.2. J. Hindman 986-3784.
PLUM HOLD 10/18/2016 10/19/2016
Note: 1. Sanitary riser diagram shall include the hand sink adjacent to unisex bathroom and domestic water riser diagram (hot and cold) shall be provided as previously requested per FBC 5th ed. 107.3.5. 2. Provide occupancy classification and occupant load calculation to determine if separate restroom facilities are needed per FBC 5th ed. 302/FBCP 5th ed. 403.2F.Reodica-386-986-4734.
PLUM HOLD 08/25/2016 08/26/2016
Note: 1. Provide sanitary and domestic water (hot and cold) riser diagrams per FBC 5th ed. 107.3.5. 2. Provide occupancy classification and occupant load calculation to determine if separate restroom facilities are needed per FBC 5th ed. 302/FBCP 5th ed. 403.2. F.Reodica -386-986-4734.
BLD HOLD 08/25/2016 08/25/2016
Note: 1. Provide a complete set of plans for the changes to this unit as already stated under permit application number 2016060705. The floorplan does not match what was existing under the previous tenants permit. 2. the life safety plan must show the occupant load and must show all equipment, fixtures and furnishings. 5th ed. FBC 107.2.1. J. Hindman 986-3784.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REVISION ¤40.00 01/05/2017
SITE PLAN 20 ¤20.00 11/23/2016
SURCHARGE FS 533.721 ¤3.62 11/23/2016
SURCHARGE - FS 468.631 ¤3.62 11/23/2016
ADMIN COMMERCIAL ¤60.00 11/23/2016
INSPECTION - COMMERCIAL ADD ¤50.00 11/23/2016
FIRE PLANS REVIEW ¤25.00 11/23/2016
PLAN CHECK FEE ¤100.00 11/23/2016
PLUMBING FEE ¤61.20 11/23/2016
Fees Total Due: ¤0.00 Total Paid: ¤363.44