I want to search for...

Permit #2016090057

Permit Details

Status: CANCEL

Parcel Id: 07-11-31-7010-00240-0480
CONDITIONED SPACE: 2323 sqft
GARAGE: 611 sqft
OPENED PORCH (WITH ROOF) : 188 sqft
OPENED PORCH (WITH ROOF) : 102 sqft
Total Square Footage: 3224 sqft
Block: 00240
Subdivision: 2137 - SECTION 10-FLORIDA PARK
Job Phone: (386)445-9393
Location Address: 60 FELWOOD LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/13/2016
NOC: RECORDED
Applicant name: ANTONIO AMARAL JR
Owner: NADA OF PALM COAST LLC

Address

13 UTILITY DRIVE

PALM COAST, FL 32137

Lot: 0480
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

AMARAL CUSTOM HOMES INC.
Status Location Address State License Number Phone Fax
CANCEL

13 Utility Drive

PALM COAST, FL 32135

CBC058062 (Exp: 08/31/2020) (386)445-9393 (386)446-0403

Sub Contractors

RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 1963

BUNNELL, FL 32110

ES12001217 (Exp: 08/31/2026) 386-437-0607 386-437-1847
THOMAS A REGULA
Status Location Address State License Number Phone Fax
INACTIVE

11320 PHILLIPS PKWY DRIVE E

JACKSONVILLE, FL 32256

CMC1250075 (Exp: 08/31/2026) 904-278-0339 904-278-0366
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
ANTONIO JR AMARAL
Status Location Address State License Number Phone Fax
CANCEL

13 Utility Drive

PALM COAST, FL 32137

CCC058004 (Exp: 08/31/2018) (386)445-9393 (386)446-0403

Inspection History

Type Request Date Result Inspector
ROOF VALLEY & METAL 01/22/2018 Disapproved - NO FEE WMILLER
Note: ROOF VALLEY METAL WAS COVERED PRIOR TO (2467 ROOF VALLEY AND METAL) INSPECTION. (NEED TO UNCOVER ALL ROOF VALLEY LININGS, FLASHING, ROOF TO WALL FLASHINGS, DRIP EDGE, AND ANY OTHER AREAS NECESSARY FOR INSPECTOR TO CHECK FOR COMPLIANCE WITH CURRENT CODES)
BLD - BUILDING FINAL 01/22/2018 Disapproved -FEE REQUIRED WMILLER
Note: TO MANY DEFICIENT ITEMS, INSPECTION STOPPED, INCOMPLETE LIST, (INSPECTION STOPPED PRIOR TO ENTRY). 1. 1549 SQUARE INCHES OF ROOF ROOF VENTS VIA TILE ROOF VENTS MISSING) (NONE FOUND) 2. BATH EXHAUSTS NOT TERMINTED PROPERLY. 3. NEED FINAL SURVEY ON SITE AT TIME OF FINAL 4. 3 inches ABOVE THE GROUND FBC, R, M1305.1.4.1 5. NEED FLASHING AT WEATHERHEAD PIPE PENETRATION THROUGH ROOF PLANE FBC R903.1, R903.2, AND R903.2.1 (INSPECTION STOPPED PRIOR TO LIVING QUATERS ENTRY) (ALSO MUST PASS ROOF 2467-ROOF VALLEY METAL PRIOR) 6. DISCONNECT WORCKING SPACE AT CONDENSER E3405.2
ROW - FINAL APRON (AFTER POUR) 01/22/2018 Disapproved -FEE REQUIRED RGROSS
Note: MISSING DOCUMENTATION. NO SWALE PLAN OR FINAL SURVEY ON SITE.
ROW - FINAL INSPECTION 01/22/2018 Disapproved - NO FEE RGROSS
Note: SEE FINAL APRON INSPECTION RESULTS. MISSING DOCUMENTATION.
FINAL SURVEY (OFFICE USE ONLY) 01/19/2018 APPROVED DREWIS
ELECTRIC - EARLY POWER 07/17/2017 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 2:30
ROW- PRE-APRON (PRE-POUR) 04/28/2017 APPROVED RGROSS
Note: READY TO POUR.
U - SEWER TIE IN 04/06/2017 APPROVED JNICHOLS
GRAVITY SEWER TEST 04/06/2017 APPROVED JGIBSON
LATH/BRICK/ WATER BARRIER 03/03/2017 APPROVED CMINI
INSULATION 02/23/2017 APPROVED CMINI
Note: THIS IS A REINSPECTION
INSULATION 02/22/2017 Disapproved -FEE REQUIRED CMINI
Note: need to frame in panel, and fire foam. nail plate on pluming needs to extend past double top plate 2"
ALL ROUGH 02/10/2017 APPROVED - AS NOTED LMILLER
Note: CORRECT NAIL PLATES AT DOUBLE TOP PLATES BY INSULATION
FRAMING 02/10/2017 APPROVED LMILLER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/30/2017 APPROVED CMINI
TIE BEAM / LINTEL 12/27/2016 APPROVED CMINI
FOUND SURVEY APPROVED (OFFICE) 12/21/2016 APPROVED JHINDMAN
MONOLITHIC SLAB 12/05/2016 APPROVED CMINI
PLUMBING 1ST ROUGH UNDERGROUND 11/28/2016 APPROVED - AS NOTED LMILLER
Note: HAVE TOILET ON SITE BY NEXT INSPECTION. TEMP TOILET 26. SANITARY FACILITIES REQUIRED B3305.1 SHALL BE PROVIDED DURING CONSTRUCTION
ROOF VALLEY & METAL
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL
Note: THIS IS A REINSPECTION
ROW - FINAL APRON (AFTER POUR)
Note: THIS IS A REINSPECTION
ROW - FINAL INSPECTION
Note: THIS IS A REINSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
SW1 COMPLETE 01/19/2018 01/19/2018
Note: Released By: DREWIS
SW1 HOLD 01/18/2018 01/19/2018
Note: Held By: DREWIS Please update NOC. Daniel Rewis 9863780
ENGIN1 COMPLETE 02/23/2017 02/23/2017
SW1 COMPLETE 02/23/2017 02/24/2017
UD1 COMPLETE 02/23/2017 02/24/2017
ZON COMPLETE 02/23/2017 02/24/2017
SW1 COMPLETE 12/20/2016 12/21/2016
Note: Released By: JHINDMAN FOUNDATION S
ENGIN1 COMPLETE 11/15/2016 11/15/2016
SW1 COMPLETE 11/15/2016 11/21/2016
MECH COMPLETE 09/28/2016 09/29/2016
URB COMPLETE 09/21/2016 09/21/2016
ZON COMPLETE 09/21/2016 09/21/2016
BLD COMPLETE 09/02/2016 09/02/2016
ELEC COMPLETE 09/02/2016 09/02/2016
ENGIN1 COMPLETE 09/02/2016 09/12/2016
MECH HOLD 09/02/2016 09/02/2016
Note: Energy performance level (EPL) display card on energy calculations shall be signed by the builder per FBCEC 5th ed. R401.3. F.Reodica - 386-986-4734.
PLUM COMPLETE 09/02/2016 09/02/2016
SW1 COMPLETE 09/02/2016 09/02/2016
UD1 COMPLETE 09/02/2016 09/06/2016
ZON HOLD 09/02/2016 09/07/2016
Note: 1. Site plan must have all lot information. Plan that was submitted has the pertinent information on the bottom blanked out. 2. Landscape plan must show proposed tree and landscape information. Note that rear landscape is required as this is considered a highly visible lot. 3. Site plan and landscape plan must depict mechanical equipment pad.
URB HOLD 09/02/2016 09/06/2016
Note: Need to add a tree and shrub legend indicating type, gallon container size and quantity and indicate the location, type, and quantity on the plan. If using a stamped site plan for landscaping need to write For Landscape Use Only on the plan.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REVISION ¤40.00 01/18/2018
REINSPECTION FEE ¤40.00 01/18/2018
NEW RESIDENTIAL INSPECTIONS ¤590.00 10/13/2016
SITE PLAN 20 ¤20.00 10/13/2016
SURCHARGE FS 533.721 ¤21.89 10/13/2016
SURCHARGE - FS 468.631 ¤21.89 10/13/2016
STORM WATER PERMIT FEES ¤80.00 10/13/2016
3% TRANS IMPACT FEE CREDIT (¤93.74) 10/13/2016
ADMIN FEE ¤20.00 10/13/2016
ELECTRIC FEE ¤237.00 10/13/2016
3% FIRE IMPACT FEE CREDIT (¤6.43) 10/13/2016
IMPACT FEE FIRE NONRESIDENTIAL ¤214.29 10/13/2016
IMPACT FEE PARKS ¤849.24 10/13/2016
IMPACT FEE SCHOOL ¤3,600.00 10/13/2016
IMPACT FEE TRANSPORTATION ¤3,124.67 10/13/2016
MECHANICAL FEE ¤237.00 10/13/2016
3% PARKS IMPACT FEE CREDIT (¤25.48) 10/13/2016
PLAN CHECK FEE ¤118.00 10/13/2016
PLUMBING FEE ¤237.00 10/13/2016
REINSPECTION FEE ¤40.00
REINSPECTION FEE ¤40.00
Fees Total Due: ¤80.00 Total Paid: ¤9,325.33