I want to search for...
Permit #2016090057
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7010-00240-0480 |
| CONDITIONED SPACE: 2323 sqft |
| GARAGE: 611 sqft |
| OPENED PORCH (WITH ROOF) : 188 sqft |
| OPENED PORCH (WITH ROOF) : 102 sqft |
| Total Square Footage: 3224 sqft |
| Block: 00240 |
| Subdivision: 2137 - SECTION 10-FLORIDA PARK |
| Job Phone: (386)445-9393 |
| Location Address: 60 FELWOOD LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/13/2016 |
| NOC: RECORDED |
| Applicant name: ANTONIO AMARAL JR |
| Owner: NADA OF PALM COAST LLC |
|
Address 13 UTILITY DRIVE PALM COAST, FL 32137 |
| Lot: 0480 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
AMARAL CUSTOM HOMES INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
13 Utility Drive PALM COAST, FL 32135 |
CBC058062 (Exp: 08/31/2020) | (386)445-9393 | (386)446-0403 |
Sub Contractors
RICHARD H SIMMONS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 1963 BUNNELL, FL 32110 |
ES12001217 (Exp: 08/31/2026) | 386-437-0607 | 386-437-1847 |
THOMAS A REGULA
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
11320 PHILLIPS PKWY DRIVE E JACKSONVILLE, FL 32256 |
CMC1250075 (Exp: 08/31/2026) | 904-278-0339 | 904-278-0366 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
ANTONIO JR AMARAL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
13 Utility Drive PALM COAST, FL 32137 |
CCC058004 (Exp: 08/31/2018) | (386)445-9393 | (386)446-0403 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROOF VALLEY & METAL | 01/22/2018 | Disapproved - NO FEE | WMILLER |
| Note: ROOF VALLEY METAL WAS COVERED PRIOR TO (2467 ROOF VALLEY AND METAL) INSPECTION. (NEED TO UNCOVER ALL ROOF VALLEY LININGS, FLASHING, ROOF TO WALL FLASHINGS, DRIP EDGE, AND ANY OTHER AREAS NECESSARY FOR INSPECTOR TO CHECK FOR COMPLIANCE WITH CURRENT CODES) | |||
| BLD - BUILDING FINAL | 01/22/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: TO MANY DEFICIENT ITEMS, INSPECTION STOPPED, INCOMPLETE LIST, (INSPECTION STOPPED PRIOR TO ENTRY). 1. 1549 SQUARE INCHES OF ROOF ROOF VENTS VIA TILE ROOF VENTS MISSING) (NONE FOUND) 2. BATH EXHAUSTS NOT TERMINTED PROPERLY. 3. NEED FINAL SURVEY ON SITE AT TIME OF FINAL 4. 3 inches ABOVE THE GROUND FBC, R, M1305.1.4.1 5. NEED FLASHING AT WEATHERHEAD PIPE PENETRATION THROUGH ROOF PLANE FBC R903.1, R903.2, AND R903.2.1 (INSPECTION STOPPED PRIOR TO LIVING QUATERS ENTRY) (ALSO MUST PASS ROOF 2467-ROOF VALLEY METAL PRIOR) 6. DISCONNECT WORCKING SPACE AT CONDENSER E3405.2 | |||
| ROW - FINAL APRON (AFTER POUR) | 01/22/2018 | Disapproved -FEE REQUIRED | RGROSS |
| Note: MISSING DOCUMENTATION. NO SWALE PLAN OR FINAL SURVEY ON SITE. | |||
| ROW - FINAL INSPECTION | 01/22/2018 | Disapproved - NO FEE | RGROSS |
| Note: SEE FINAL APRON INSPECTION RESULTS. MISSING DOCUMENTATION. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 01/19/2018 | APPROVED | DREWIS |
| ELECTRIC - EARLY POWER | 07/17/2017 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 2:30 | |||
| ROW- PRE-APRON (PRE-POUR) | 04/28/2017 | APPROVED | RGROSS |
| Note: READY TO POUR. | |||
| U - SEWER TIE IN | 04/06/2017 | APPROVED | JNICHOLS |
| GRAVITY SEWER TEST | 04/06/2017 | APPROVED | JGIBSON |
| LATH/BRICK/ WATER BARRIER | 03/03/2017 | APPROVED | CMINI |
| INSULATION | 02/23/2017 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 02/22/2017 | Disapproved -FEE REQUIRED | CMINI |
| Note: need to frame in panel, and fire foam. nail plate on pluming needs to extend past double top plate 2" | |||
| ALL ROUGH | 02/10/2017 | APPROVED - AS NOTED | LMILLER |
| Note: CORRECT NAIL PLATES AT DOUBLE TOP PLATES BY INSULATION | |||
| FRAMING | 02/10/2017 | APPROVED | LMILLER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/30/2017 | APPROVED | CMINI |
| TIE BEAM / LINTEL | 12/27/2016 | APPROVED | CMINI |
| FOUND SURVEY APPROVED (OFFICE) | 12/21/2016 | APPROVED | JHINDMAN |
| MONOLITHIC SLAB | 12/05/2016 | APPROVED | CMINI |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/28/2016 | APPROVED - AS NOTED | LMILLER |
| Note: HAVE TOILET ON SITE BY NEXT INSPECTION. TEMP TOILET 26. SANITARY FACILITIES REQUIRED B3305.1 SHALL BE PROVIDED DURING CONSTRUCTION | |||
| ROOF VALLEY & METAL | |||
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | |||
| Note: THIS IS A REINSPECTION | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| Note: THIS IS A REINSPECTION | |||
| ROW - FINAL INSPECTION | |||
| Note: THIS IS A REINSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 01/19/2018 | 01/19/2018 |
| Note: Released By: DREWIS | |||
| SW1 | HOLD | 01/18/2018 | 01/19/2018 |
| Note: Held By: DREWIS Please update NOC. Daniel Rewis 9863780 | |||
| ENGIN1 | COMPLETE | 02/23/2017 | 02/23/2017 |
| SW1 | COMPLETE | 02/23/2017 | 02/24/2017 |
| UD1 | COMPLETE | 02/23/2017 | 02/24/2017 |
| ZON | COMPLETE | 02/23/2017 | 02/24/2017 |
| SW1 | COMPLETE | 12/20/2016 | 12/21/2016 |
| Note: Released By: JHINDMAN FOUNDATION S | |||
| ENGIN1 | COMPLETE | 11/15/2016 | 11/15/2016 |
| SW1 | COMPLETE | 11/15/2016 | 11/21/2016 |
| MECH | COMPLETE | 09/28/2016 | 09/29/2016 |
| URB | COMPLETE | 09/21/2016 | 09/21/2016 |
| ZON | COMPLETE | 09/21/2016 | 09/21/2016 |
| BLD | COMPLETE | 09/02/2016 | 09/02/2016 |
| ELEC | COMPLETE | 09/02/2016 | 09/02/2016 |
| ENGIN1 | COMPLETE | 09/02/2016 | 09/12/2016 |
| MECH | HOLD | 09/02/2016 | 09/02/2016 |
| Note: Energy performance level (EPL) display card on energy calculations shall be signed by the builder per FBCEC 5th ed. R401.3. F.Reodica - 386-986-4734. | |||
| PLUM | COMPLETE | 09/02/2016 | 09/02/2016 |
| SW1 | COMPLETE | 09/02/2016 | 09/02/2016 |
| UD1 | COMPLETE | 09/02/2016 | 09/06/2016 |
| ZON | HOLD | 09/02/2016 | 09/07/2016 |
| Note: 1. Site plan must have all lot information. Plan that was submitted has the pertinent information on the bottom blanked out. 2. Landscape plan must show proposed tree and landscape information. Note that rear landscape is required as this is considered a highly visible lot. 3. Site plan and landscape plan must depict mechanical equipment pad. | |||
| URB | HOLD | 09/02/2016 | 09/06/2016 |
| Note: Need to add a tree and shrub legend indicating type, gallon container size and quantity and indicate the location, type, and quantity on the plan. If using a stamped site plan for landscaping need to write For Landscape Use Only on the plan. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 01/18/2018 |
| REINSPECTION FEE | ¤40.00 | 01/18/2018 |
| NEW RESIDENTIAL INSPECTIONS | ¤590.00 | 10/13/2016 |
| SITE PLAN 20 | ¤20.00 | 10/13/2016 |
| SURCHARGE FS 533.721 | ¤21.89 | 10/13/2016 |
| SURCHARGE - FS 468.631 | ¤21.89 | 10/13/2016 |
| STORM WATER PERMIT FEES | ¤80.00 | 10/13/2016 |
| 3% TRANS IMPACT FEE CREDIT | (¤93.74) | 10/13/2016 |
| ADMIN FEE | ¤20.00 | 10/13/2016 |
| ELECTRIC FEE | ¤237.00 | 10/13/2016 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.43) | 10/13/2016 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤214.29 | 10/13/2016 |
| IMPACT FEE PARKS | ¤849.24 | 10/13/2016 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 10/13/2016 |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | 10/13/2016 |
| MECHANICAL FEE | ¤237.00 | 10/13/2016 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 10/13/2016 |
| PLAN CHECK FEE | ¤118.00 | 10/13/2016 |
| PLUMBING FEE | ¤237.00 | 10/13/2016 |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| Fees | Total Due: ¤80.00 | Total Paid: ¤9,325.33 |