I want to search for...
Permit #2016090179
Permit Details
Status: COED
| Parcel Id: 07-11-31-7025-000C1-0040 |
| Block: 000C1 |
| Subdivision: 2196 - ALBERTSONS #4469 |
| Job Phone: 386-673-2508 |
| Location Address: 1499 PALM COAST PKWY NW |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 11/17/2016 |
| NOC: RECORDED |
| Applicant name: RAMEY ALLEN BUDGEN |
| Owner: ACROSS THE POND DEVELOPMENTS LLC |
|
Address 609 SOUTH RIDGEWOOD AVE DAYTONA BEACH, FL 32114 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤9,000.00 |
| Job Description: UNIT C - COSMO PROF BEAUTY SUPPLY |
| Type: CN |
Contractor
BUDGEN CONSTRUCTION INC.
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
22 WINDING WOODS TRAIL ORMOND BEACH, FL 32174 |
CGC1504474 (Exp: 08/31/2022) | 386-673-2508 | 386-673-2570 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
JAMES MIKEL
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
327 PARQUE DRIVE ORMOND BEACH, FL 32174 |
SUITE 5 ORMOND BEACH, FL 32174 |
CFC057226 (Exp: 08/31/2026) | 386-671-9015 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 12/28/2016 | APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION | |||
| ELECTRIC FINAL | 12/20/2016 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: 1.Exit lights and emergency lights are not working on battery power 5th ed fbc 1006. 2. electrical panels are not marked correctly. 5th ed.FBC 107.4. 3. Cannot verify the ground screw from the prevoius inspection. 5th ed. FBC 110.1. | |||
| PLUMBING FINAL | 12/20/2016 | APPROVED | JHINDMAN |
| BUILDING FINAL | 12/20/2016 | APPROVED | JHINDMAN |
| FIRE FINAL | 12/20/2016 | APPROVED | JHINDMAN |
| U - UTILITY COMMERCIAL FINAL | 12/20/2016 | FINAL APPROVED | JNICHOLS |
| PLUMBING 2ND ROUGH | 12/01/2016 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ABOVE CEILING | 11/18/2016 | APPROVED | JHINDMAN |
| ELECTRIC 2ND ROUGH | 11/18/2016 | APPROVED - AS NOTED | RMARTIN |
| Note: need ground screw in outlet box,marked on plan and revision on back switch location by final | |||
| PLUMBING 1ST ROUGH | 11/18/2016 | APPROVED - AS NOTED | JHINDMAN |
| Note: inspection is not needed | |||
| PLUMBING 2ND ROUGH | 11/18/2016 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: 1. plumbing riser is not per plan 5th ed. FBC 107.4. 2. sanitary piping does not have 10 ft head pressure 5th ed. FBC Plumbing 312.2. |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 12/13/2016 | 12/16/2016 |
| PLUM | COMPLETE | 11/22/2016 | 11/30/2016 |
| Note: Revision - changed plumbing riser diagrams. | |||
| PLUM | COMPLETE | 11/10/2016 | 11/16/2016 |
| PLUM | HOLD | 11/04/2016 | 11/07/2016 |
| Note: Repeat comment: Provide sanitary riser diagram with signature and license number of plumbing contractor per FBC 5th ed. 107.3.5. | |||
| ELEC | COMPLETE | 10/26/2016 | 10/26/2016 |
| BLD | COMPLETE | 10/26/2016 | 10/27/2016 |
| FI1 | COMPLETE | 10/26/2016 | 10/26/2016 |
| PLUM | HOLD | 10/26/2016 | 10/27/2016 |
| Note: Provide sanitary and domestic water (hot and cold) riser diagrams per FBC 5th ed. 107.3.5. | |||
| MECH | COMPLETE | 10/26/2016 | 10/27/2016 |
| UD1 | COMPLETE | 10/26/2016 | 10/28/2016 |
| ZON | COMPLETE | 10/26/2016 | 10/27/2016 |
| BLD | HOLD | 09/14/2016 | 09/14/2016 |
| Note: 1. Provide a complete set of plans that include occupancy type, occupant load and building type. 5th edition Florida building Code 107.3.5. 2. The proposed plans must show compliance with the 5th edition Florida Building Code Accessibility. J. Hindman 986-3784. | |||
| ELEC | HOLD | 09/14/2016 | 09/14/2016 |
| Note: Please provide a complete electrical plan with exiting items to be demoed, remain and added per the NEC 2011. Electrical plan is to be signed and sealed by a licensed engineer or the signature and license number of the electrical contractor provided per the FBC 5th ed. 105.3.1.2. -DC. Rewis 986-4736 | |||
| FI1 | HOLD | 09/14/2016 | 09/14/2016 |
| Note: 1. Provide a Life Safety plan per 5th edition Florida fire Prevention Code 101 4.2. J. Hindman 986-3784. | |||
| MECH | HOLD | 09/14/2016 | 09/15/2016 |
| Note: 1. Provide the use and occupancy classification of existing space and the proposed space per FBC 5th ed. 302. 2. Provide occupant load calculation and if there is an increase in mechanical ventilation, heating and cooling load calculations is required to determine if the existing hvac units capacity can handle the additional load per FBC existing building 5th ed. 1009/1012.1.1.2. | |||
| PLUM | HOLD | 09/14/2016 | 09/15/2016 |
| Note: Provide plumbing plan and scope of work sufficient for review, construction and inspection either prepared by design professional or plumbing contractor with signature and license number per FBC 5th ed. 107.1. F.Reodica -386-986-4734. | |||
| UD1 | COMPLETE | 09/14/2016 | 09/14/2016 |
| ZON | COMPLETE | 09/14/2016 | 09/15/2016 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 12/24/2016 |
| REVISION | ¤40.00 | 12/19/2016 |
| REVISION | ¤40.00 | 12/19/2016 |
| REINSPECTION FEE | ¤40.00 | 12/19/2016 |
| SITE PLAN 20 | ¤20.00 | 11/17/2016 |
| SURCHARGE FS 533.721 | ¤4.66 | 11/17/2016 |
| SURCHARGE - FS 468.631 | ¤4.66 | 11/17/2016 |
| ADMIN COMMERCIAL | ¤60.00 | 11/17/2016 |
| INSPECTION - COMMERCIAL ADD | ¤63.00 | 11/17/2016 |
| ELECTRIC FEE | ¤65.40 | 11/17/2016 |
| FIRE PLANS REVIEW | ¤25.00 | 11/17/2016 |
| PLAN CHECK FEE | ¤100.00 | 11/17/2016 |
| PLUMBING FEE | ¤65.40 | 11/17/2016 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤568.12 |