I want to search for...

Permit #2016100955

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-00460-0080
CONDITIONED SPACE: 2342 sqft
GARAGE: 583 sqft
OPENED PORCH (WITH ROOF) : 260 sqft
OPENED PORCH (WITH ROOF) : 57 sqft
Total Square Footage: 3242 sqft
Block: 00460
Subdivision: 2176 - SECTION 37-LAKEVIEW
Job Phone: 904-338-1270
Location Address: 58 LANCELOT DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/09/2016
NOC: RECORDED
Applicant name: DAVID VINCENT KIMBLE
Owner: EVERLAST HOMES INC

Address

13245 ATLANTIC BLVD

JACKSONVILLE, FL 32225

Address

STE 4-398

JACKSONVILLE, FL 32225

Lot: 0080
Contracted Stated Job Value: ¤108,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

EVERLAST HOMES, INC
Status Location Address State License Number Phone
ACTIVE

13245 ATLANTIC BLVD

JACKSONVILLE, FL 32246

CBC1260552 (Exp: 08/31/2026) 904-545-6476

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
JOHN ROBERT BLEVINS JR
Status Location Address State License Number Phone Fax
ACTIVE

17 PORWYN LANE

PALM COAST, FL 32164

CAC1816125 (Exp: 08/31/2026) 386-585-8283 386-263-2096
GARY WAYNE EVERS
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 740106

ORANGE CITY, FL 32763

CFC050566 (Exp: 08/31/2026) 386-775-0909 386-775-0918
DEBORAH MAXINE JACKSON
Status Location Address State License Number Phone
ACTIVE

1165 SOUTH 5TH

MACCLENNY, FL 32063

CCC1330709 (Exp: 08/31/2026) 904-322-9409

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 04/11/2017 FINAL APPROVED JNICHOLS
BLD - BUILDING FINAL 04/10/2017 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 04/07/2017 CANCELLED BY APPLICANT JCOLASANTI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 04/06/2017 Disapproved -FEE REQUIRED JCOLASANTI
Note: need to change breaker for AHU unit 30 installed 60 amp required....switch outlet in rear guest BR not working....breaker for front guest bedroom keeps tripping. tighten fauset guest bath
ROW - FINAL INSPECTION 04/06/2017 APPROVED RGROSS
Note: THIS IS A REINSPECTION. APPROVED
ROW - FINAL INSPECTION 04/05/2017 Disapproved -FEE REQUIRED RGROSS
Note: REMOVE REMNANTS OF BLDG MATERIALS (INSULATION) AND TRASH FROM ADJACENT DITCH.
ROW - FINAL APRON (AFTER POUR) 04/05/2017 APPROVED RGROSS
Note: APPROVED
FINAL SURVEY (OFFICE USE ONLY) 03/31/2017 APPROVED JHINDMAN
ELECTRIC - EARLY POWER 03/21/2017 APPROVED - AS NOTED RMARTIN
Note: THIS IS A REINSPECTION SPOKE TO DELL FPL RELEASED EARLY POWER 3:10
ELECTRIC - EARLY POWER 03/20/2017 Disapproved -FEE REQUIRED RMARTIN
Note: UNUSED OPENINGS IN PANEL, DOES NOT HAVE PROPER PANEL BLANKS, NEC.110.12 A
U - SEWER TIE IN 03/15/2017 APPROVED JNICHOLS
Note: THIS IS A REINSPECTION
U - SEWER TIE IN 03/09/2017 CANCELLED BY APPLICANT DSPENCER
Note: THIS IS A REINSPECTION
U - SEWER TIE IN 03/07/2017 CANCELLED BY APPLICANT JNICHOLS
ROW- PRE-APRON (PRE-POUR) 03/02/2017 APPROVED CTROHA
Note: READY TO POUR It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the specs shown on the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete.
LATH/BRICK/ WATER BARRIER 02/17/2017 APPROVED JCOLASANTI
INSULATION 02/09/2017 APPROVED JCOLASANTI
ALL ROUGH 02/06/2017 CANCELLED BY APPLICANT AIRS WEB
Note: THIS IS A REINSPECTION
ALL ROUGH 02/03/2017 APPROVED - AS NOTED LMILLER
Note: NEED NAIL PLATES FOR PLUMBING STACKS AT TOP PLATES. NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE. AND SHALL EXTEND NO LESS THAN 2 inches ABOVE SOLE PLATES AND BELOW TOP PLATES, (MUST BE MINIMUM OF 0.0575 inch., 1.463mm, 16 GAGE) (WHERE THE PIPE IS LESS THAN 1.5 inches FROM THE NEAREST EDGE) NAIL PLATES FOR ELECTRIC, (CHECK ALL), FBC E3802.1
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/30/2017 APPROVED - AS NOTED JCOLASANTI
Note: NEED TO BRACE GABLE ENDS AT CEILING PER PLAN....NEED TO BRACE TRUSSES AT VALLEY FRONT ENTRY AND GUEST BEDROOM. WILL CHECK AT ALL ROUGH
ROOF VALLEY & METAL 01/30/2017 APPROVED JCOLASANTI
TIE BEAM / LINTEL 01/06/2017 APPROVED JCOLASANTI
FOUND SURVEY APPROVED (OFFICE) 01/05/2017 APPROVED FREODICA
MONOLITHIC SLAB 12/21/2016 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 12/20/2016 Disapproved - NO FEE JCOLASANTI
Note: meed to cut angle at interior footing per plan. termite must be applied before visqueen is placed
GRAVITY SEWER TEST 12/13/2016 APPROVED LMILLER
PLUMBING 1ST ROUGH UNDERGROUND 12/09/2016 APPROVED JCOLASANTI

Review History

Department Status Date In Date Out
SW1 COMPLETE 03/30/2017 03/31/2017
Note: Released By: JHINDMAN final survey ok per Gary L.
SW1 COMPLETE 01/05/2017 01/05/2017
Note: Released By: FREODICA foundation
PLUM COMPLETE 11/02/2016 11/03/2016
URB COMPLETE 11/02/2016 11/02/2016
BLD COMPLETE 10/26/2016 10/26/2016
ELEC COMPLETE 10/26/2016 10/26/2016
ENGIN1 COMPLETE 10/26/2016 10/31/2016
MECH COMPLETE 10/26/2016 10/27/2016
PLUM HOLD 10/26/2016 10/27/2016
Note: Provide sanitary riser diagram prepared either by design professional or plumbing contractor with signature and license number indicated on the riser diagram per FBC 5th ed. 105.3.1.2. F.Reodica - 386-986-4734.
SW1 COMPLETE 10/26/2016 10/26/2016
UD1 COMPLETE 10/26/2016 10/31/2016
ZON COMPLETE 10/26/2016 10/27/2016
URB HOLD 10/26/2016 10/28/2016
Note: Need to trade front understory tree for one of the shade trees rear. the code states front tree must be shade type.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 04/12/2017
REINSPECTION FEE ¤40.00 04/12/2017
REINSPECTION FEE ¤40.00 04/12/2017
REINSPECTION FEE ¤40.00 04/12/2017
NEW RESIDENTIAL INSPECTIONS ¤594.00 11/09/2016
SITE PLAN 20 ¤20.00 11/09/2016
SURCHARGE FS 533.721 ¤22.01 11/09/2016
SURCHARGE - FS 468.631 ¤22.01 11/09/2016
STORM WATER PERMIT FEES ¤80.00 11/09/2016
3% TRANS IMPACT FEE CREDIT (¤93.74) 11/09/2016
ADMIN FEE ¤20.00 11/09/2016
ELECTRIC FEE ¤238.20 11/09/2016
3% FIRE IMPACT FEE CREDIT (¤6.43) 11/09/2016
IMPACT FEE FIRE NONRESIDENTIAL ¤214.29 11/09/2016
IMPACT FEE PARKS ¤849.24 11/09/2016
IMPACT FEE SCHOOL ¤3,600.00 11/09/2016
IMPACT FEE TRANSPORTATION ¤3,124.67 11/09/2016
MECHANICAL FEE ¤238.20 11/09/2016
3% PARKS IMPACT FEE CREDIT (¤25.48) 11/09/2016
PLAN CHECK FEE ¤118.80 11/09/2016
PLUMBING FEE ¤238.20 11/09/2016
Fees Total Due: ¤0.00 Total Paid: ¤9,413.97