Permit #2016110287

Permit Details

Status: COED

Parcel Id: 07-11-31-7059-00600-0030
CONDITIONED SPACE: 1691 sqft
GARAGE: 430 sqft
OPENED PORCH (WITH ROOF) : 184 sqft
OPENED PORCH (WITH ROOF) : 30 sqft
Total Square Footage: 2335 sqft
Block: 00600
Subdivision: -
Job Phone: 386-449-9413
Location Address: 12 SMITH TR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/20/2017
NOC: RECORDED
Applicant name: STEVE HARKINS
Owner: BROWN, DONALD & PHYLLIS

Address

12 SMITH TR

PALM COAST, FL 32164

Lot: 0030
Contracted Stated Job Value: ¤210,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

HARKINS CUSTOM CONSTRUCTION INC.
Status Location Address State License Number Phone
ACTIVE

665 STREET TRAIL

BUNNELL, FL 32110

CBC1253997 (Exp: 08/31/2026) 386-449-9413

Sub Contractors

JERRY F TORDEUR
Status Location Address State License Number Phone Fax
CANCEL

4244 JACKSON ST

Port Orange, FL 32119

CFC033863 (Exp: 08/31/2020) (386) 761-3526 (386)761-0132
ALFRED N FYOCK JR
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

387 SAULS

ORMOND BEACH, FL 32174

ST

ORMOND BEACH, FL 32174

CCC1329075 (Exp: 08/31/2026) 386-566-6112 386-673-4299
GERALD EDWARD MASTERS JR
Status Location Address State License Number Phone
ACTIVE

505 HERBERT STREET

PORT ORANGE, FL 32129

EC13003217 (Exp: 08/31/2026) (386)304-2600
ROBERT JOHN TROWBRIDGE
Status Location Address State License Number Phone
INACTIVE

3801 Long Grove Lane

Port Orange, 32119

CAC057234 (Exp: 08/31/2024) (386) 767-9735

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 09/21/2017 FINAL APPROVED MBACON
ROW - FINAL INSPECTION 09/20/2017 APPROVED CTROHA
Note: corrections made
BLD - BUILDING FINAL 09/20/2017 FINAL APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 09/18/2017 Disapproved -FEE REQUIRED DROCKWELL
Note: THIS IS A REINSPECTION/ Provide access to tub motor and electric/Attic access cover must be rated for flame spread
FINAL APRON (AFTER POUR/DRIVEWAY) 09/15/2017 APPROVED - AS NOTED CTROHA
Note: *****************THIS CODE IS NOT TO BE USED *************************************
ROW - FINAL APRON (AFTER POUR) 09/15/2017 APPROVED CTROHA
Note: FINAL SURVEY SHOWS CULVERT PIPE AND SWALE IN TOLERANCE
ROW - FINAL INSPECTION 09/15/2017 Disapproved -FEE REQUIRED CTROHA
Note: REMOVE ALL CONSTRUCTION DEBRIS FROM ADJACENT LOTS AND AT THE REAR OF THE PROPERTY CLEAN OUT CULVERT ENDS SOD ADJ SWALE WITH BAHIA SOD AND MATCH EXISTING GRADE WHERE THE DUMPSTER AND PORT-O-LET WERE SITTING
STORMWATER FINAL 09/15/2017 APPROVED CTROHA
Note: FINAL SURVEY SHOWS FINAL SWALE GRADE IN TOLERANCE
BLD - BUILDING FINAL 09/15/2017 CANCELLED BY APPLICANT JMONTARULI
Note: No power yet
FINAL SURVEY (OFFICE USE ONLY) 09/14/2017 APPROVED JHINDMAN
ROW - FINAL INSPECTION 08/30/2017 CANCELLED BY APPLICANT CTROHA
Note: CALLED IN
STORMWATER FINAL 08/30/2017 CANCELLED BY APPLICANT CTROHA
Note: CALLED IN
FINAL APRON (AFTER POUR/DRIVEWAY) 08/30/2017 CANCELLED BY APPLICANT CTROHA
Note: CALLED IN
ROW - DRAINAGE 08/25/2017 APPROVED CTROHA
Note: WORK COMPLETE
ELECTRIC - EARLY POWER 08/23/2017 APPROVED - AS NOTED RMARTIN
Note: THIS IS A REINSPECTION SPOKE TO SUSAN FPL RELEASED EARLY POWER 10:50
ROW - DRAINAGE 08/22/2017 Disapproved - NO FEE CTROHA
Note: PUT UP SILT FENCE IN THE SWALE ON BOTH SIDES OF THE PROPERTY THERE IS OIL RESIDUE IN THE NEIGHBORS SWALE THAT MAY OR MAY NOT HAVE COME FROM THE CONSTRUCTION MOVE KNIGHT JON BOY ON TO YOUR LOT WE WILL REINSPECT ON FRIDAY THE 25
ROW - FINAL APRON (AFTER POUR) 08/21/2017 Disapproved -FEE REQUIRED CTROHA
Note: *NOT READY FOR INSPECTION* NO FINAL SURVEY SOD IS NOT IN FORM BOARDS HAVE NOT BEEN REMOVED
GRAVITY SEWER TEST 08/16/2017 APPROVED JGIBSON
ROW- PRE-APRON (PRE-POUR) 08/10/2017 APPROVED - AS NOTED CTROHA
Note: READY TO POUR It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete. ON SITE WITH BUILDER MAKING CORRECTIONS TO FORM BOARDS
U - SEWER TIE IN 08/07/2017 APPROVED MBACON
INSULATION 07/06/2017 APPROVED DROCKWELL
LATH/BRICK/ WATER BARRIER 06/29/2017 APPROVED DROCKWELL
ALL ROUGH 06/22/2017 APPROVED - AS NOTED DROCKWELL
Note: Frame service panel
FRAMING 06/22/2017 APPROVED DROCKWELL
ELECTRIC - EARLY POWER 06/21/2017 Disapproved - NO FEE DROCKWELL
Note: No tug here.This is fed over-head.Cannot call early power until All-rough is approved and house is in final stages
ROOF VALLEY & METAL 05/30/2017 APPROVED DROCKWELL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/26/2017 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/25/2017 Disapproved -FEE REQUIRED DROCKWELL
Note: Garage bearing wall per plan detail/Block flat top trusses osb cannot exceed 24in span
TIE BEAM / LINTEL 05/05/2017 APPROVED DROCKWELL
FOUND SURVEY APPROVED (OFFICE) 04/28/2017 APPROVED JHINDMAN
MONOLITHIC SLAB 04/07/2017 APPROVED DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 04/04/2017 APPROVED JGIBSON

Review History

Department Status Date In Date Out
SW1 COMPLETE 09/07/2017 09/14/2017
Note: Released By: JHINDMAN
SW1 HOLD 08/29/2017 09/01/2017
Note: Held By: WMILLER final s Need to meet Minimum drainage from home to 10ft out, at back, and front left of home. STORM WATER RUN-OFF… FBC R401.3 DRAINAGE… lots shall be graded to drain surface water away from foundation walls. The grade shall fall a minimum of 6 inches within the first 10 feet.
ZON COMPLETE 08/11/2017 08/13/2017
Note: Released By: TAWILLIAMS
SW1 COMPLETE 04/27/2017 04/28/2017
Note: Released By: JHINDMAN foundation s
PLUM COMPLETE 03/21/2017 03/22/2017
Note: Revised sanitary riser diagram.
BLD COMPLETE 03/06/2017 03/07/2017
ELEC COMPLETE 03/06/2017 03/07/2017
PLUM HOLD 03/06/2017 03/08/2017
Note: Provide revised sanitary riser diagram to match with revised floor plan with signature and license number of plumbing contractor per FBC 5th ed. 107.2.1. F.Reodica -386-986-4734
MECH COMPLETE 01/13/2017 01/19/2017
MECH HOLD 01/04/2017 01/10/2017
Note: Submitted correction for hvac plan shall have signature and license number of hvac contractor per FBC 5th ed, 107.3.4.2. F.Reodica- 386-986-4734.
URB COMPLETE 12/05/2016 12/07/2016
UD1 COMPLETE 12/05/2016 12/06/2016
Note: This is a PEP Tank area. The Pep Panel will be placed 5 feet from the front corner of the building on the same side of the building as the PEP tank that is marked on the Utility marked Site plan. Make sure the electrician places the PEP power wire between 3 feet and 5 feet from the ground. The plumber should exit the slab with the sewer pipe on the side of the building the tank will be on and matching the utility marked site plan, this will reduce any piping under driveways or sidewalks and minimize the fall required. The sewer tie-in inspection must be called in the day before the tie-in. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in visual inspection so he can witness the tie-in. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON COMPLETE 12/05/2016 12/05/2016
ELEC COMPLETE 12/05/2016 12/13/2016
PLUM COMPLETE 12/05/2016 12/08/2016
MECH HOLD 12/05/2016 12/08/2016
Note: 1. Supply air duct connection to diffusers serving kitchen and dining room are missing on submitted hvac plan. Provide them for clarity per FBC 5th ed. 107.2.1. 2. Provide signature of the builder on energy performance level (EPL) display card per FBCEC 5th ed. R401.3 as previously requested.. 3. Provide sensible and latent capacity of selected hvac units per FBCEC R403.6.1 as previously requested or complete the information on heating/cooling load summary on energy calculations. F.Reodica -386-986-4734.
BLD COMPLETE 11/07/2016 11/08/2016
ELEC HOLD 11/07/2016 11/08/2016
Note: 1. Provide electrical load calculations. 2011 NEC art. 220. J. Hindman 986-3784.
ENGIN1 COMPLETE 11/07/2016 11/15/2016
MECH HOLD 11/07/2016 11/08/2016
Note: 1. Provide hvac plan either prepared by design professional or hvac contractor with his signature and license number indicated on plan per FBC 5th ed. 105.3.1.2. 2. Provide signature of the builder on energy performance level (EPL) display card per FBCEC 5th ed. R401.3. 3. Provide manufacture, model number of outdoor and indoor units, sensible and total cooling capacity of selected hvac units per FBCEC R403.6.1. F.Reodica -386-986-4734.
PLUM HOLD 11/07/2016 11/08/2016
Note: Provide sanitary riser diagram either prepared by design professional or plumbing contractor with his signature and license number indicated on the riser per FBC 5th ed. 107.2.1. F.Reodica -386-986-4734.
SW1 COMPLETE 11/07/2016 11/08/2016
UD1 HOLD 11/07/2016 11/08/2016
Note: PEP Panel is not shown in the electrical plan. Submit a new electrical plan showing PEP Panel on the building on the same side of the building as indicated in the Utility marked site plan. PEP Panel requires dedicated 20 amp service.
ZON HOLD 11/07/2016 11/08/2016
Note: 1)Landscaping plan must be separate from the site plan 2)Driveway will be concrete or pavers? 3)What type of sod? If St.Augustine indicate irrigation 4)One additional code tree is required
URB HOLD 11/07/2016 11/08/2016
Note: 1: Need the type of sod being used if St Augustine indicate 100% irrigation being installed. 2: Need to add 1 code tree no credit given for pigmy date palm. 3: If using a site plan for a landscape plan need to write in Bold ( For Landscape Use Only) as a header on the plan. 4: Need a plant and tree legend indicating the caliper size and height of trees, And the container size and quantity of all.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 09/20/2017
REINSPECTION FEE ¤40.00 09/20/2017
REINSPECTION FEE ¤40.00 08/29/2017
REINSPECTION FEE ¤40.00 08/29/2017
REVISION ¤40.00 03/28/2017
REVISION ¤40.00 03/28/2017
SITE PLAN 20 ¤20.00 01/20/2017
SURCHARGE FS 533.721 ¤16.78 01/20/2017
SURCHARGE - FS 468.631 ¤16.78 01/20/2017
STORM WATER PERMIT FEES ¤80.00 01/20/2017
3% TRANS IMPACT FEE CREDIT (¤93.74) 01/20/2017
NEW RESIDENTIAL INSPECTIONS ¤428.00 01/20/2017
ADMIN FEE ¤20.00 01/20/2017
ELECTRIC FEE ¤188.40 01/20/2017
3% FIRE IMPACT FEE CREDIT (¤6.43) 01/20/2017
IMPACT FEE FIRE NONRESIDENTIAL ¤214.29 01/20/2017
IMPACT FEE PARKS ¤849.24 01/20/2017
IMPACT FEE SCHOOL ¤3,600.00 01/20/2017
IMPACT FEE TRANSPORTATION ¤3,124.67 01/20/2017
MECHANICAL FEE ¤188.40 01/20/2017
3% PARKS IMPACT FEE CREDIT (¤25.48) 01/20/2017
PLAN CHECK FEE ¤85.60 01/20/2017
PLUMBING FEE ¤188.40 01/20/2017
Fees Total Due: ¤0.00 Total Paid: ¤9,134.91