I want to search for...
Permit #2016120051
Permit Details
Status: COED
| Parcel Id: 41-11-31-4975-00000-0010 |
| Total Square Footage: 2763 sqft |
| Block: 00000 |
| Subdivision: 2272 - ISLAND WALK AT PALM COAST |
| Job Phone: (386)986-2224 |
| Location Address: 250 PALM COAST PKWY NE |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 01/11/2017 |
| NOC: RECORDED |
| Applicant name: WILLIAM P WHITLEY III |
| Owner: BRANCH ISLAND WALK ASSOCIATES LP |
|
Address SUITE 600 ATLANTA, GA 30326 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤221,000.00 |
| Job Description: UNIT 210/211- INTERIOR ALTERATIONS FOR "MASSAGE ENVY" |
| Type: CN |
Contractor
WHITLEY BUILDERS LLC
| Status | Location Address | State License Number | Phone |
| CANCEL |
6 BUTTONWELL LANE PALM COAST, FL 32137 |
CBC1255213 (Exp: 08/31/2018) | (386)986-2224 |
Sub Contractors
CHARLES WEYANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 1261 FLAGLER BEACH, FL 32136 |
CAC1815058 (Exp: 08/31/2026) | (386)246-7745 |
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
Inspection History
| Type | Request Date | Result | Inspector |
| FIRE FINAL | 05/22/2017 | FINAL APPROVED | JHINDMAN |
| U - UTILITY COMMERCIAL FINAL | 05/19/2017 | FINAL APPROVED | LFITZGERALD |
| ELECTRIC FINAL | 05/19/2017 | APPROVED | RMARTIN |
| PLUMBING FINAL | 05/19/2017 | APPROVED | JGIBSON |
| BUILDING FINAL | 05/19/2017 | FINAL APPROVED | CMINI |
| HVAC FINAL | 05/11/2017 | APPROVED | CMINI |
| ABOVE CEILING | 05/09/2017 | APPROVED | CMINI |
| ELECTRIC - EARLY POWER | 05/03/2017 | APPROVED - AS NOTED | RMARTIN |
| Note: spoke to dell fpl released early power 3:10 | |||
| FRAMING | 03/16/2017 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 2ND ROUGH | 03/16/2017 | APPROVED | CMINI |
| ELECTRIC 2ND ROUGH | 03/16/2017 | APPROVED - AS NOTED | RMARTIN |
| Note: WALLS ONLY, NEED REVISION ON ELECTRIC BY ELECTRIC FINAL | |||
| HVAC ROUGH | 03/16/2017 | APPROVED - AS NOTED | CMINI |
| Note: need to revise layout to match existing plans | |||
| FRAMING | 02/22/2017 | PARTIALLY APPROVED | CMINI |
| Note: Dimising walls | |||
| BLD - FLATWORK-SIDEWALK/PADS/PATIOS/LANAI/LANDINGS | 01/31/2017 | APPROVED - AS NOTED | CMINI |
| Note: trap primers need to be installed. slab inspection. termite treatment cert in permit pack | |||
| ELECTRIC 1ST ROUGH | 01/31/2017 | APPROVED - AS NOTED | RMARTIN |
| Note: UNDER SLAB INTERIOR | |||
| ELECTRIC OTHER | 01/30/2017 | Disapproved - NO FEE | RMARTIN |
| Note: CALLED IN WRONG INSPECTION NEEDED TO BE 1ST ROUGH ELECTRIC = UNDERGROUND | |||
| PLUMBING 1ST ROUGH | 01/24/2017 | APPROVED | CMINI |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 02/02/2017 | 02/07/2017 |
| Note: Revision; changed hvac plan, energy calcs. and rtu's capacity from 3.5 tons to 5 tos each. | |||
| MECH | COMPLETE | 01/09/2017 | 01/11/2017 |
| PLUM | COMPLETE | 01/09/2017 | 01/11/2017 |
| PLUM | HOLD | 12/28/2016 | 01/04/2017 |
| Note: Review comments on sanitary riser diagram: 1. Provide vents for hand sinks at multi-purpose rooms 109 and 111, at unisex toilet (lavatory) and at utility sink (shown as hand sink) adjacent to washing machine per FBCP 5th ed. 901.1. 2. The kitchen sink shall be shown above ground similar to hand sinks for clarity per FBC 5th ed. 107.2.1. F.Reodica - 386-986-4734. | |||
| MECH | HOLD | 12/22/2016 | 01/04/2017 |
| Note: Submitted correction for revised heating/cooling load calculations do not meet the latent capacity of selected hvac units as previously requested. The total latent capacity of selected hvac units is less the total calculated latent load. Clarify per FBC 5th ed. 107.2.1/FBCEC 5th ed. 403.2.1. F.Reodica -386-986-4734. | |||
| BLD | COMPLETE | 12/22/2016 | 12/28/2016 |
| BLD | COMPLETE | 12/05/2016 | 12/13/2016 |
| ELEC | COMPLETE | 12/05/2016 | 12/13/2016 |
| FI1 | COMPLETE | 12/05/2016 | 12/13/2016 |
| MECH | HOLD | 12/05/2016 | 12/14/2016 |
| Note: The total latent capacity of selected hvac units is less the total calculated latent load. Clarify per FBC 5th ed. 107.2.1/FBCEC 5th ed. 403.2.1. F.Reodica -386-986-4734. | |||
| PLUM | HOLD | 12/05/2016 | 12/13/2016 |
| Note: 1. Provide sanitary riser diagram per FBC 5th ed.107.3.5. 2. Coordinate the pipe sizes of domestic cold water supply shown on plan with the riser diagram for clarification per FBC 5th ed. 107.2.1. F.Reodica -386-986-4734. | |||
| UD1 | COMPLETE | 12/05/2016 | 12/05/2016 |
| ZON | COMPLETE | 12/05/2016 | 12/07/2016 |
| SW1 | COMPLETE | 12/05/2016 | 12/06/2016 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 03/15/2017 |
| SITE PLAN 20 | ¤20.00 | 01/11/2017 |
| SURCHARGE FS 533.721 | ¤13.68 | 01/11/2017 |
| SURCHARGE - FS 468.631 | ¤13.68 | 01/11/2017 |
| ADMIN COMMERCIAL | ¤60.00 | 01/11/2017 |
| INSPECTION - COMMERCIAL ADD | ¤1,547.00 | 01/11/2017 |
| ELECTRIC FEE | ¤192.60 | 01/11/2017 |
| MECHANICAL FEE | ¤192.60 | 01/11/2017 |
| PLAN CHECK FEE | ¤254.15 | 01/11/2017 |
| PLUMBING FEE | ¤192.60 | 01/11/2017 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤2,526.31 |