Permit #2016120140
Permit Details
Status: COED
| Parcel Id: 07-11-31-7002-00030-0090 |
| Block: 00030 |
| Subdivision: 2218 - SECTION 2-FLORIDA PARK |
| Job Phone: 386-238-1570 |
| Location Address: 9 FLORIDA PARK DR |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 01/20/2017 |
| NOC: RECORDED |
| Applicant name: SALVATORE MICHAEL SAMMARO |
| Owner: NETPIQUE LLC |
|
Address 6 MERIDAN HOME LANE PALM COAST, FL 32164 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤207,000.00 |
| Job Description: INTERIOR/EXTERIOR REMODEL- "NETPIQUE" |
| Type: CN |
Contractor
COMMERCIAL CONSTRUCTION INC.
| Status | Location Address | State License Number | Phone |
| CANCEL |
7 SUNSHINE BLVD ORMOND BEACH, FL 32174 |
CGC1507910 (Exp: 08/31/2020) | 386-238-1570 |
Sub Contractors
DARREN GLEN BROWN
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
163 DEEP WOOD WAY Ormond Beach, FL 32174 |
EC13003395 (Exp: 08/31/2024) | (386) 615-8956 | (386)615-4531 |
PAUL SHELDON MARTINES
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1115 ENTERPRISE COURT HOLLY HILL, FL 32117 |
CAC041253 (Exp: 08/31/2022) | 386-252-5767 | 386-252-5768 |
ISAAC WALTER JOHNSTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
887 BRENTWOOD DRIVE Daytona Beach, FL 32117 |
CFC023634 (Exp: 08/31/2026) | (386) 252-7047 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 04/21/2017 | APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION per contractor | |||
| BUILDING FINAL | 04/17/2017 | FINAL APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 04/13/2017 | APPROVED | JHINDMAN |
| U - UTILITY COMMERCIAL FINAL | 04/13/2017 | FINAL APPROVED | JNICHOLS |
| BUILDING FINAL | 04/13/2017 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: 1. The slider door track height does not meet ada for the threshold. 5th ed. FBC acessibility 303.1. 2. An outstanding revision must be answered for plan review. | |||
| ELECTRIC FINAL | 04/06/2017 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: NEED REVISION SUBMITTED TO BUILDING DEPT. AND APPROVED ON SITE FOR INSPECTION , ALSO WATERHEATER NEEDS DISCONNECT OR BREAKER LOCK, NOT IN SITE OF PANEL NEC 422.30 | |||
| PLUMBING FINAL | 04/06/2017 | APPROVED - AS NOTED | JGIBSON |
| Note: NEED VACUME BREAKERS ON HOSE BIBS AND SHOCK ARRESTOR ON ICE MAKER BOX BEFORE BUILDING FINAL | |||
| HVAC FINAL | 04/06/2017 | APPROVED | CMINI |
| ELECTRIC TEMP POLE | 03/30/2017 | APPROVED | RMARTIN |
| ELECTRIC - EARLY POWER | 03/29/2017 | APPROVED - AS NOTED | RMARTIN |
| Note: spoke to susan fpl released early power 11:45 | |||
| LATH/BRICK/WATER BARRIER | 03/23/2017 | APPROVED | CMINI |
| FRAMING | 03/03/2017 | APPROVED | CMINI |
| ELECTRIC 2ND ROUGH | 03/03/2017 | APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION | |||
| ELECTRIC 2ND ROUGH | 03/02/2017 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: NEED CHECK ALL FOR NAIL PLATES AND GROUND CONNECTIONS ON BOXES SEVERAL MISSED, CHECK ALL | |||
| HVAC ROUGH | 03/02/2017 | APPROVED | CMINI |
| COLUMN | 02/28/2017 | APPROVED | CMINI |
| PLUMBING 2ND ROUGH | 02/24/2017 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 2ND ROUGH | 02/23/2017 | Disapproved -FEE REQUIRED | CMINI |
| Note: head pressure on DWV not holding FBCp312. nail gaurds missing FBCp 305.6 | |||
| MONOLITHIC SLAB | 02/21/2017 | APPROVED | CMINI |
| FOOTER | 02/21/2017 | APPROVED | CMINI |
| FOOTER | 02/20/2017 | CANCELLED BY APPLICANT | AIRS WEB |
| MONOLITHIC SLAB | 02/20/2017 | CANCELLED BY APPLICANT | AIRS WEB |
| PLUMBING 1ST ROUGH | 02/17/2017 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 1ST ROUGH | 02/10/2017 | Disapproved -FEE REQUIRED | CMINI |
| Note: Floor drain not in plans (location marked on plumbing plan page P-1) Missing Plumbing for electric Water Cooler (location marked on plumbing plan page P-1) Missing plumbing for mop sink (location marked on plumbing plan page P-1) 10' head PBC. 302 Recheck supply after added location. |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/17/2017 | 04/19/2017 |
| BLD | HOLD | 04/10/2017 | 04/11/2017 |
| Note: 1. Plan must be signed and sealed by the design professional or signed by the electrician with his license number. 5th ed. FBC 107.1. 2. Prior revision comment for wall has not been answered. (The top of the wall must be roofed or flashed to prevent water intrusion as stucco is a moisture permeable material. per 5th edition Florida building Code 1503.1 and1503.2. J. Hindman 986-3784.). | |||
| BLD | HOLD | 03/28/2017 | 03/28/2017 |
| Note: 1. The top of the wall must be roofed or flashed to prevent water intrusion as stucco is a moisture permeable material. per 5th edition Florida building Code 1503.1 and1503.2. J. Hindman 986-3784. | |||
| ELEC | COMPLETE | 01/06/2017 | 01/17/2017 |
| MECH | COMPLETE | 01/06/2017 | 01/17/2017 |
| PLUM | COMPLETE | 01/06/2017 | 01/17/2017 |
| BLD | COMPLETE | 12/06/2016 | 12/14/2016 |
| ELEC | HOLD | 12/06/2016 | 12/14/2016 |
| Note: 1. Provide electrical load calculations 2011 NEC art. 220. J. Hindman 986-3784. | |||
| FI1 | COMPLETE | 12/06/2016 | 12/14/2016 |
| MECH | HOLD | 12/06/2016 | 12/14/2016 |
| Note: 1. Provide updated reference code to FBC mechanical code 5th edition (2014) on sheet M-1. 2. Provide manufacturer's performance data of selected hvac units total capacity, sensible and latent per FBCEC 5th ed. C403.2.1. 3. Occupant load shown on sheet A-2 does not match with those shown on outdoor air calculation and heating/cooling load calculation. Coordinate for clarity per FBC 5th ed. 107.2.1. F.Reodica-386-986-4734. | |||
| PLUM | HOLD | 12/06/2016 | 12/14/2016 |
| Note: 1. Provide drinking fountain and service sink and include sanitary and domestic water riser diagrams per FBCP 5th ed. 403.1/FBC 5th ed. 107.3.5. F.Reodica -386-986-4734. | |||
| UD1 | COMPLETE | 12/06/2016 | 12/06/2016 |
| ZON | COMPLETE | 12/06/2016 | 12/07/2016 |
| SW1 | COMPLETE | 12/06/2016 | 12/06/2016 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 04/20/2017 |
| REINSPECTION FEE | ¤40.00 | 04/20/2017 |
| REINSPECTION FEE | ¤40.00 | 04/20/2017 |
| REINSPECTION FEE | ¤40.00 | 04/20/2017 |
| REINSPECTION FEE | ¤40.00 | 04/20/2017 |
| SITE PLAN 20 | ¤20.00 | 01/20/2017 |
| SURCHARGE FS 533.721 | ¤13.06 | 01/20/2017 |
| SURCHARGE - FS 468.631 | ¤13.06 | 01/20/2017 |
| ADMIN COMMERCIAL | ¤60.00 | 01/20/2017 |
| INSPECTION - COMMERCIAL ADD | ¤1,449.00 | 01/20/2017 |
| ELECTRIC FEE | ¤184.20 | 01/20/2017 |
| MECHANICAL FEE | ¤184.20 | 01/20/2017 |
| PLAN CHECK FEE | ¤238.05 | 01/20/2017 |
| PLUMBING FEE | ¤184.20 | 01/20/2017 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤2,545.77 |