Permit #2016120140

Permit Details

Status: COED

Parcel Id: 07-11-31-7002-00030-0090
Block: 00030
Subdivision: 2218 - SECTION 2-FLORIDA PARK
Job Phone: 386-238-1570
Location Address: 9 FLORIDA PARK DR
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 01/20/2017
NOC: RECORDED
Applicant name: SALVATORE MICHAEL SAMMARO
Owner: NETPIQUE LLC

Address

6 MERIDAN HOME LANE

PALM COAST, FL 32164

Lot: 0090
Contracted Stated Job Value: ¤207,000.00
Job Description: INTERIOR/EXTERIOR REMODEL- "NETPIQUE"
Type: CN

Contractor

COMMERCIAL CONSTRUCTION INC.
Status Location Address State License Number Phone
CANCEL

7 SUNSHINE BLVD

ORMOND BEACH, FL 32174

CGC1507910 (Exp: 08/31/2020) 386-238-1570

Sub Contractors

DARREN GLEN BROWN
Status Location Address State License Number Phone Fax
INACTIVE

163 DEEP WOOD WAY

Ormond Beach, FL 32174

EC13003395 (Exp: 08/31/2024) (386) 615-8956 (386)615-4531
PAUL SHELDON MARTINES
Status Location Address State License Number Phone Fax
CANCEL

1115 ENTERPRISE COURT

HOLLY HILL, FL 32117

CAC041253 (Exp: 08/31/2022) 386-252-5767 386-252-5768
ISAAC WALTER JOHNSTON
Status Location Address State License Number Phone
ACTIVE

887 BRENTWOOD DRIVE

Daytona Beach, FL 32117

CFC023634 (Exp: 08/31/2026) (386) 252-7047

Inspection History

Type Request Date Result Inspector
ELECTRIC FINAL 04/21/2017 APPROVED RMARTIN
Note: THIS IS A REINSPECTION per contractor
BUILDING FINAL 04/17/2017 FINAL APPROVED CMINI
Note: THIS IS A REINSPECTION
FIRE FINAL 04/13/2017 APPROVED JHINDMAN
U - UTILITY COMMERCIAL FINAL 04/13/2017 FINAL APPROVED JNICHOLS
BUILDING FINAL 04/13/2017 Disapproved -FEE REQUIRED JHINDMAN
Note: 1. The slider door track height does not meet ada for the threshold. 5th ed. FBC acessibility 303.1. 2. An outstanding revision must be answered for plan review.
ELECTRIC FINAL 04/06/2017 Disapproved -FEE REQUIRED RMARTIN
Note: NEED REVISION SUBMITTED TO BUILDING DEPT. AND APPROVED ON SITE FOR INSPECTION , ALSO WATERHEATER NEEDS DISCONNECT OR BREAKER LOCK, NOT IN SITE OF PANEL NEC 422.30
PLUMBING FINAL 04/06/2017 APPROVED - AS NOTED JGIBSON
Note: NEED VACUME BREAKERS ON HOSE BIBS AND SHOCK ARRESTOR ON ICE MAKER BOX BEFORE BUILDING FINAL
HVAC FINAL 04/06/2017 APPROVED CMINI
ELECTRIC TEMP POLE 03/30/2017 APPROVED RMARTIN
ELECTRIC - EARLY POWER 03/29/2017 APPROVED - AS NOTED RMARTIN
Note: spoke to susan fpl released early power 11:45
LATH/BRICK/WATER BARRIER 03/23/2017 APPROVED CMINI
FRAMING 03/03/2017 APPROVED CMINI
ELECTRIC 2ND ROUGH 03/03/2017 APPROVED RMARTIN
Note: THIS IS A REINSPECTION
ELECTRIC 2ND ROUGH 03/02/2017 Disapproved -FEE REQUIRED RMARTIN
Note: NEED CHECK ALL FOR NAIL PLATES AND GROUND CONNECTIONS ON BOXES SEVERAL MISSED, CHECK ALL
HVAC ROUGH 03/02/2017 APPROVED CMINI
COLUMN 02/28/2017 APPROVED CMINI
PLUMBING 2ND ROUGH 02/24/2017 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
PLUMBING 2ND ROUGH 02/23/2017 Disapproved -FEE REQUIRED CMINI
Note: head pressure on DWV not holding FBCp312. nail gaurds missing FBCp 305.6
MONOLITHIC SLAB 02/21/2017 APPROVED CMINI
FOOTER 02/21/2017 APPROVED CMINI
FOOTER 02/20/2017 CANCELLED BY APPLICANT AIRS WEB
MONOLITHIC SLAB 02/20/2017 CANCELLED BY APPLICANT AIRS WEB
PLUMBING 1ST ROUGH 02/17/2017 APPROVED CMINI
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH 02/10/2017 Disapproved -FEE REQUIRED CMINI
Note: Floor drain not in plans (location marked on plumbing plan page P-1) Missing Plumbing for electric Water Cooler (location marked on plumbing plan page P-1) Missing plumbing for mop sink (location marked on plumbing plan page P-1) 10' head PBC. 302 Recheck supply after added location.

Review History

Department Status Date In Date Out
BLD COMPLETE 04/17/2017 04/19/2017
BLD HOLD 04/10/2017 04/11/2017
Note: 1. Plan must be signed and sealed by the design professional or signed by the electrician with his license number. 5th ed. FBC 107.1. 2. Prior revision comment for wall has not been answered. (The top of the wall must be roofed or flashed to prevent water intrusion as stucco is a moisture permeable material. per 5th edition Florida building Code 1503.1 and1503.2. J. Hindman 986-3784.).
BLD HOLD 03/28/2017 03/28/2017
Note: 1. The top of the wall must be roofed or flashed to prevent water intrusion as stucco is a moisture permeable material. per 5th edition Florida building Code 1503.1 and1503.2. J. Hindman 986-3784.
ELEC COMPLETE 01/06/2017 01/17/2017
MECH COMPLETE 01/06/2017 01/17/2017
PLUM COMPLETE 01/06/2017 01/17/2017
BLD COMPLETE 12/06/2016 12/14/2016
ELEC HOLD 12/06/2016 12/14/2016
Note: 1. Provide electrical load calculations 2011 NEC art. 220. J. Hindman 986-3784.
FI1 COMPLETE 12/06/2016 12/14/2016
MECH HOLD 12/06/2016 12/14/2016
Note: 1. Provide updated reference code to FBC mechanical code 5th edition (2014) on sheet M-1. 2. Provide manufacturer's performance data of selected hvac units total capacity, sensible and latent per FBCEC 5th ed. C403.2.1. 3. Occupant load shown on sheet A-2 does not match with those shown on outdoor air calculation and heating/cooling load calculation. Coordinate for clarity per FBC 5th ed. 107.2.1. F.Reodica-386-986-4734.
PLUM HOLD 12/06/2016 12/14/2016
Note: 1. Provide drinking fountain and service sink and include sanitary and domestic water riser diagrams per FBCP 5th ed. 403.1/FBC 5th ed. 107.3.5. F.Reodica -386-986-4734.
UD1 COMPLETE 12/06/2016 12/06/2016
ZON COMPLETE 12/06/2016 12/07/2016
SW1 COMPLETE 12/06/2016 12/06/2016

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 04/20/2017
REINSPECTION FEE ¤40.00 04/20/2017
REINSPECTION FEE ¤40.00 04/20/2017
REINSPECTION FEE ¤40.00 04/20/2017
REINSPECTION FEE ¤40.00 04/20/2017
SITE PLAN 20 ¤20.00 01/20/2017
SURCHARGE FS 533.721 ¤13.06 01/20/2017
SURCHARGE - FS 468.631 ¤13.06 01/20/2017
ADMIN COMMERCIAL ¤60.00 01/20/2017
INSPECTION - COMMERCIAL ADD ¤1,449.00 01/20/2017
ELECTRIC FEE ¤184.20 01/20/2017
MECHANICAL FEE ¤184.20 01/20/2017
PLAN CHECK FEE ¤238.05 01/20/2017
PLUMBING FEE ¤184.20 01/20/2017
Fees Total Due: ¤0.00 Total Paid: ¤2,545.77