Permit #2016120359

Permit Details

Status: COED

Parcel Id: 07-11-31-7001-000B0-0010
Block: 000B0
Subdivision: 1238 - PALM HARBOR CENTER REPLAT
Job Phone: (386)931-1917
Location Address: 28 OLD KINGS RD N
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 03/27/2017
NOC: RECORDED
Applicant name: BRAD MICHAEL THOMAS
Owner: ALSON FAMILY LIMITED PARTNERSHIP

Address

89 CIMMARON DRIVE

PALM COAST, FL 32137

Lot: 0010
Contracted Stated Job Value: ¤5,500.00
Job Description: UNIT C- INTERIOR ELECTRICAL & PLUMBING MODIFICATIONS - "CIAO BELLA SALON & ACADEMY, INC."
Type: CN

Contractor

AUBURN HOMES INC.
Status Location Address State License Number Phone
HOLD

1 HARGROVE GRADE STE 1E

PALM COAST, FL 32137

CGC1506292 (Exp: 08/31/2020) (386)931-1917

Sub Contractors

STEVEN DUANE DENSLOW
Status Location Address State License Number Phone Fax
ACTIVE

317 RIO PINR DR

Ormond Beach, FL 32174

EC0001678 (Exp: 08/31/2026) 386-233-1553 386-673-5994
HEATH EDWARD SANFORD
Status Location Address State License Number Phone Fax
ACTIVE

1351 HAZELNUT ST

BUNNELL, FL 32110

CFC1427527 (Exp: 08/31/2026) 386-445-2532 386-445-5575
JOHN ROBERT BLEVINS JR
Status Location Address State License Number Phone Fax
ACTIVE

17 PORWYN LANE

PALM COAST, FL 32164

CAC1816125 (Exp: 08/31/2026) 386-585-8283 386-263-2096

Inspection History

Type Request Date Result Inspector
BUILDING FINAL 06/09/2017 FINAL APPROVED CMINI
FIRE FINAL 06/08/2017 FINAL APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
PLUMBING FINAL 06/08/2017 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
FIRE FINAL 06/06/2017 Disapproved -FEE REQUIRED JHINDMAN
Note: THIS IS A REINSPECTION Provide an exit emergency light in the Salon room 2nd request. nfpa ffpc 101 7.9.
FIRE FINAL 06/02/2017 Disapproved -FEE REQUIRED JHINDMAN
Note: THIS IS A REINSPECTION DOORS LOCKED NEED ACCESS FOR INSPECTION, WE ARE NOT ALLOWED TO OPEN LOCK BOXES, CITY ORDANENCE
ELECTRIC FINAL 06/02/2017 APPROVED - AS NOTED RMARTIN
Note: NEED TO MOVE ONE LAY-IN LIGHT OUT OF NEW RESTROOM TO CORRECT LOCATION ON PLAN
FIRE FINAL 06/01/2017 Disapproved -FEE REQUIRED JHINDMAN
Note: 1. provide emergency light and exit sign in the salon per nfpa FFPC101 7.9
ABOVE CEILING 06/01/2017 APPROVED CMINI
U - UTILITY COMMERCIAL FINAL 06/01/2017 FINAL APPROVED JNICHOLS
HVAC FINAL 06/01/2017 APPROVED CMINI
PLUMBING FINAL 06/01/2017 Disapproved -FEE REQUIRED JGIBSON
Note: MENS BATHROOM TOILET TANK HANDLE MUST BE TO THE OPEN APPROACH SIDE 604.2 ''ADA''
ELECTRIC FINAL 06/01/2017 Disapproved -FEE REQUIRED RMARTIN
Note: DOORS LOCKED NEED ACCESS FOR INSPECTION, WE ARE NOT ALLOWED TO OPEN LOCK BOXES, CITY ORDANENCE
ELECTRIC 2ND ROUGH 04/28/2017 APPROVED - AS NOTED RMARTIN
Note: NEED P-RING IN RESTROOM ON SWITCH/GFCI
HVAC ROUGH 04/26/2017 APPROVED CMINI
MONOLITHIC SLAB 04/20/2017 APPROVED CMINI
PLUMBING 1ST ROUGH 04/19/2017 APPROVED - AS NOTED JGIBSON
Note: NEED PICTURE OF WATER CLOSET TEST
PLUMBING 2ND ROUGH 04/19/2017 APPROVED JGIBSON

Review History

Department Status Date In Date Out
MECH COMPLETE 03/24/2017 03/27/2017
PLUM COMPLETE 03/24/2017 03/27/2017
MECH HOLD 03/16/2017 03/20/2017
Note: Repeat comment #3: Provide existing and proposed hvac plans suitable for review, construction and inspection either prepared by design professional or hvac contractor per FBC 5th ed.107.3.5/107.2.1. Please note that salon with pedicure station requires mechanical exhaust or source of capture system per FBCM 5th ed. 403.2.1 exc3. F.Reodica - 386-986-4734.
PLUM HOLD 03/16/2017 03/20/2017
Note: Repeat comment Additional comments based on revised sanitary riser diagram: 1. Provide vent for the service sink (mop sink) per FBCP 5th ed. 910.1 2. Provide additional vent for the new hair shampoo sink per FBCP 5th ed. 911.1.
PLUM HOLD 03/03/2017 03/07/2017
Note: Repeat comment for item 1: 1. Provide domestic water (hot and cold) riser diagram per FBC 5th ed. 107.3.5. Additional comments based on revised sanitary riser diagram: 1. Provide vent for the service sink (mop sink) per FBCP 5th ed. 910.1 2. Provide additional vent for the new hair shampoo sink per FBCP 5th ed. 911.1.
MECH HOLD 03/03/2017 03/07/2017
Note: Repeat comment: Provide existing and proposed hvac plans suitable for review, construction and inspection either prepared by design professional or hvac contractor per FBC 5th ed.107.3.5/107.2.1. Please note that salon with pedicure station requires mechanical exhaust or source of capture system per FBCM 5th ed. 403.2.1 exc3. F.Reodica - 386-986-4734.
MECH HOLD 01/27/2017 01/31/2017
Note: Provide existing and proposed hvac plans suitable for review, construction and inspection either prepared by design professional or hvac contractor per FBC 5th ed.107.3.5/107.2.1. Please note that salon with pedicure station requires mechanical exhaust or source of capture system per FBCM 5th ed. 403.2.1 exc3. F.Reodica - 386-986-4734.
BLD COMPLETE 01/27/2017 01/31/2017
FI1 COMPLETE 01/27/2017 01/31/2017
ELEC COMPLETE 01/27/2017 01/31/2017
PLUM HOLD 01/27/2017 01/31/2017
Note: 1. Provide domestic water (hot and cold) riser diagram per FBC 5th ed. 107.3.5. 2. Separate bathroom is required for each sex when occupant load including employees and customers exceeds 15 people per FBCP 5th ed. 403.2. 3. Sanitary riser diagram shows (2) floor drains for pedicure chairs but not shown on floor plan. Coordinate per FBC 5th ed. 107.2.1. F.Reodica-386-986-4734.
PLUM HOLD 12/08/2016 12/15/2016
Note: Provide existing and proposed plumbing plans signed and sealed by design professional per FBC 5th ed. 107.3.5. F.Reodica - 386-986-4734.
UD1 COMPLETE 12/08/2016 12/08/2016
ZON COMPLETE 12/08/2016 12/08/2016
BLD HOLD 12/08/2016 12/15/2016
Note: 1. Provide a signed and sealed floorplan that identifies the existing and proposed work. This unit was part of a two unit business. 5th ed. FBC 107.3.5. J. Hindman 986-3784.
ELEC HOLD 12/08/2016 12/15/2016
Note: 1. Provide a complete floorplan that identifies the existing and new electrical. 5th ed. FBC 107.3.5. J. Hindman 986-3784.
FI1 HOLD 12/08/2016 12/15/2016
Note: 1. Provide a life safety plan. 5th ed. FBC 107.3.5. J. Hindman 986-3784.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 06/08/2017
REINSPECTION FEE ¤40.00 06/08/2017
REINSPECTION FEE ¤40.00 06/08/2017
REINSPECTION FEE ¤40.00 06/08/2017
REINSPECTION FEE ¤40.00 06/08/2017
SITE PLAN 20 ¤20.00 03/27/2017
SURCHARGE FS 533.721 ¤5.56 03/27/2017
SURCHARGE - FS 468.631 ¤5.56 03/27/2017
ADMIN COMMERCIAL ¤60.00 03/27/2017
INSPECTION - COMMERCIAL ADD ¤50.00 03/27/2017
ELECTRIC FEE ¤63.60 03/27/2017
MECHANICAL FEE ¤63.60 03/27/2017
PLAN CHECK FEE ¤100.00 03/27/2017
PLUMBING FEE ¤63.60 03/27/2017
Fees Total Due: ¤0.00 Total Paid: ¤631.92