I want to search for...

Permit #2016120625

Permit Details

Status: COED

CONDITIONED SPACE: 3150 sqft
GARAGE: 604 sqft
OPENED PORCH (WITH ROOF) : 578 sqft
OPENED PORCH (WITH ROOF) : 62 sqft
Total Square Footage: 4394 sqft
Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II
Job Phone: 386-236-4133
Location Address: 5 TURKEY OAK LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/27/2017
NOC: RECORDED
Applicant name: LEONARDO CIRO SANCLEMENTE
Owner: LAUSIER, LUC M & JACQUELINE L

Address

6326 KARMICH ST

FAIRFAX STATION, VA 22039

Lot: 131
Contracted Stated Job Value: ¤399,736.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INTERVEST CONSTRUCTION, INC.
Status Location Address State License Number Phone
CANCEL

2379 BEVILLE RD

DAYTONA BEACH, FL 32119

CBC1261237 (Exp: 08/31/2020) 386-236-4133

Sub Contractors

STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
CHARLES H KULP
Status Location Address State License Number Phone Fax
CANCEL

5401 ENERGY AIR CT

ORLANDO, FL 32810

CAC018270 (Exp: 08/31/2022) 407-886-3729 407-886-7580
GARY WAYNE EVERS
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 740106

ORANGE CITY, FL 32763

CFC050566 (Exp: 08/31/2026) 386-775-0909 386-775-0918
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937
KEN DEPRINZIO
Status Location Address State License Number Phone Fax
ACTIVE

325 WALKER STREET

HOLLY HILL, FL 32117

11351 (Exp: 08/31/2026) 386-672-8494 386-673-7856

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/21/2017 FINAL APPROVED CMINI
ROW - FINAL APRON (AFTER POUR) 08/21/2017 APPROVED RGROSS
Note: THIS IS A REINSPECTION. APPROVED
ROW - FINAL INSPECTION 08/21/2017 APPROVED RGROSS
Note: APPROVED
FINAL SURVEY (OFFICE USE ONLY) 08/17/2017 APPROVED FREODICA
U -UTILITY RESIDENTIAL FINAL 08/11/2017 FINAL APPROVED JNICHOLS
ROW - FINAL APRON (AFTER POUR) 08/11/2017 CANCELLED BY APPLICANT RGROSS
Note: cancelled
U-CROSS CONNECTION 08/01/2017 APPROVED LFITZGERALD
ELECTRIC - EARLY POWER 07/24/2017 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 10:50
ROW- PRE-APRON (PRE-POUR) 06/23/2017 PARTIALLY APPROVED RGROSS
Note: APPROVED FOR APRON POUR. PAVER DRIVEWAY. NOTE THAT MIAMI CURB DAMAGE SHOULD BE CUT OUT AND REPAIRED DURING THE POUR. BASE ON SITE.
INSULATION 05/31/2017 APPROVED CMINI
GAS ROUGH 05/31/2017 APPROVED CMINI
LATH/BRICK/ WATER BARRIER 05/26/2017 APPROVED CMINI
ALL ROUGH 05/25/2017 APPROVED CMINI
U - SEWER TIE IN 05/16/2017 APPROVED LFITZGERALD
GRAVITY SEWER TEST 05/04/2017 APPROVED JGIBSON
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/26/2017 APPROVED LMILLER
ROOF VALLEY & METAL 04/26/2017 APPROVED LMILLER
Note: THIS IS A REINSPECTION
WALL SHEATHING 04/24/2017 APPROVED DROCKWELL
ROOF VALLEY & METAL 04/19/2017 PARTIALLY APPROVED LMILLER
Note: LOOKED AT ROOF SHEATHING ONLY.... SUPER TRIED TO CALL IN ROOF SHEATHING BUT COULD NOT GET THE SYSTEM TO ADD IT. ROOF SHEATHING ONLY APPROVED
ELECTRIC-TUG 04/06/2017 APPROVED RMARTIN
Note: SPOKE TO DELL FPL RELEASED TUG POWER 3:10
ELEV CERT-FOUNDATION APPROVAL 04/06/2017 APPROVED DRAMIREZ
TIE BEAM / LINTEL 04/05/2017 APPROVED LMILLER
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 04/04/2017 Disapproved -FEE REQUIRED LMILLER
Note: CHANGES IN HEIGHT R609.2.5 AND FIGURE 609.2.5 UPPER AND LOWER BONDBEAMS MUST BE CONTINUOUSE, HAVE VERTICLE STEEL AND GROUTED SOLID AND MUST HAVE A FILLED CELL UNDER EACH CELL ADJOINING CHANGES IN HEIGHT
FOUND SURVEY APPROVED (OFFICE) 03/30/2017 APPROVED JHINDMAN
MONOLITHIC SLAB 03/17/2017 APPROVED LMILLER
PLUMBING 1ST ROUGH UNDERGROUND 03/14/2017 APPROVED JGIBSON

Review History

Department Status Date In Date Out
PLFM COMPLETE 08/23/2017 08/23/2017
Note: Released By: DBEVAN Comments have been addressed.
PLFM HOLD 08/17/2017 08/18/2017
Note: Held By: DBEVAN 1. For Section C2 a) through h), all elevation should be to the tenth decimal place. The previously provided elevation certificate dated 08-04-17 reflected this standard. For example C2 a) was 11.6; the submitted certificate C2 a) is 11.57. Also, update the sign-seal dates; both certificates reflect 08-04-17. 2. The final survey note #5 reflects FIRM MAP NO. 12035C0137D. The elevation certificate reflects FIRM MAP NO. 12035C0141D which is correct according to City resources. Provide an amended survey with the correct panel information.
SW1 COMPLETE 08/16/2017 08/17/2017
Note: Released By: FREODICA final survey correction
PLFM HOLD 08/09/2017 08/10/2017
Note: Held By: DRAMIREZ A-8 (a), (b) and (c) should be N/A and not "0" . B-9 -Base Flood Elevation of 9.0 is missing the foot mark. The base flood elevation should be 9.0'.
SW1 HOLD 08/07/2017 08/11/2017
Note: Held By: JHINDMAN FINAL Survey drainage does not flow per approved plan. J. Hindman 986-3784.
SW1 COMPLETE 06/28/2017 06/28/2017
Note: Released By: FREODICA FOUNDATION S (revised)
PLFM COMPLETE 04/05/2017 04/06/2017
PLFM HOLD 03/30/2017 04/03/2017
Note: Section A7 of the elevation certificate should reflect 1A, not 1B based on conversations conducted with certifying surveyor.
SW1 COMPLETE 03/30/2017 03/30/2017
Note: Released By: JHINDMAN FOUNDATION S
PLFM COMPLETE 01/23/2017 01/24/2017
Note: Elevation certificate at the "construction" stage has been deemed complete and previous comments addressed.
BLD COMPLETE 01/23/2017 01/26/2017
PLFM HOLD 01/06/2017 01/06/2017
Note: The provided construction plans indicate that an attached garage is being proposed. Complete Section A9 of the elevation certificate and resubmit an amended certificate. A proposed elevation was provided for Section C2.d) which dually indicates the plans for an attached garage. After review of the remaining sections, no additional errors were identified.
ELEC COMPLETE 01/06/2017 01/17/2017
BLD HOLD 01/06/2017 01/17/2017
Note: 1. On sheet A-3 Provide attic vent calculations that comply with 5th ed. FBC R 806.2. J. Hindman 986-3784. (50 percent is the maximum of the upper cross ventilation allowed with a 1/300 factor).
BLD HOLD 12/15/2016 12/21/2016
Note: 1. On sheet A-3 Provide attic vent calculations that comply with 5th ed. FBC R 806.2. J. Hindman 986-3784.
ELEC HOLD 12/15/2016 12/21/2016
Note: 1. Provide electrical load calculations per 2011 nec 220. 2. Receptacles missing in bedroom 2 and 5 on wall next to entry door with switches. 2011 NEC 210.52. J. Hindman 986-3784.
ENGIN1 COMPLETE 12/15/2016 12/15/2016
MECH COMPLETE 12/15/2016 12/20/2016
PLUM COMPLETE 12/15/2016 12/20/2016
SW1 COMPLETE 12/15/2016 12/21/2016
UD1 COMPLETE 12/15/2016 12/19/2016
ZON COMPLETE 12/15/2016 12/15/2016
PLFM HOLD 12/15/2016 12/19/2016
Note: 1. Within Section D in the “Place Seal Here” box, the certifying professional must also sign and date on top of the seal. 2. Include Section E and G as part of resubmittal. Section G (page 4) is necessary for processing permit reviews and accommodating possible future community comments. Informational: The provided elevation certificate has been deemed sufficient at this time. Please note that an additional elevation certificate will be required at two (2) future stages: 1) Building Under Construction (at foundation) and 2) Finished Construction (final)

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 08/22/2017
NEW RESIDENTIAL INSPECTIONS ¤800.00 01/27/2017
SITE PLAN 20 ¤20.00 01/27/2017
SURCHARGE FS 533.721 ¤28.50 01/27/2017
SURCHARGE - FS 468.631 ¤28.50 01/27/2017
STORM WATER PERMIT FEES ¤80.00 01/27/2017
3% TRANS IMPACT FEE CREDIT (¤93.74) 01/27/2017
ADMIN FEE ¤20.00 01/27/2017
ELECTRIC FEE ¤300.00 01/27/2017
3% FIRE IMPACT FEE CREDIT (¤6.43) 01/27/2017
IMPACT FEE FIRE NONRESIDENTIAL ¤214.29 01/27/2017
IMPACT FEE PARKS ¤849.24 01/27/2017
IMPACT FEE SCHOOL ¤3,600.00 01/27/2017
IMPACT FEE TRANSPORTATION ¤3,124.67 01/27/2017
MECHANICAL FEE ¤300.00 01/27/2017
3% PARKS IMPACT FEE CREDIT (¤25.48) 01/27/2017
PLAN CHECK FEE ¤160.00 01/27/2017
PLUMBING FEE ¤300.00 01/27/2017
Fees Total Due: ¤0.00 Total Paid: ¤9,739.55