Permit #2016120764

Permit Details

Status: COED

Parcel Id: 33-11-31-3061-00030-0010
CONDITIONED SPACE: 2864 sqft
GARAGE: 499 sqft
OPENED PORCH (WITH ROOF) : 91 sqft
OPENED PORCH (WITH ROOF) : 809 sqft
Total Square Footage: 4263 sqft
Block: 00030
Subdivision: 2108 - Hidden Lakes- Phase II-Toscana
Job Phone: 863-420-2100
Location Address: 15 NEW WATER OAK DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/26/2017
NOC: RECORDED
Applicant name: YUVAL BOTANSKY
Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC

Address

131 CHADWICK DRIVE

DAVENPORT, FL 33837

Lot: 0010
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

APPLIED BUILDING DEVELOPMENT COMPANY - OAKHILLS IN
Status Location Address State License Number Phone Fax
ACTIVE

131 CHADWICK DRIVE

DAVENPORT, FL 33837

CRC1330762 (Exp: 08/31/2026) 863-420-2100 386-517-6865

Sub Contractors

JOSEPH H STRADA JR
Status Location Address State License Number Phone Fax
CANCEL

531 CODISCO WAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2018) (407)333-2665 (407)585-1002
TERRY HILE BURD
Status Location Address State License Number Phone Fax
INACTIVE

PO Box 180308

CASSELBERRY, FL 32707

CAC1814423 (Exp: 08/31/2024) (407) 831-3600 (407)831-2893
KYLE G ROE
Status Location Address State License Number Phone Fax
INACTIVE

2048 APEX COURT

APOPKA, FL 32703

CFC1425725 (Exp: 08/31/2024) 407-898-2023 407-648-5654
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937

Inspection History

Type Request Date Result Inspector
FINAL SURVEY (OFFICE USE ONLY) 01/10/2018 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION Reviewed by Jerry Hindman on 12-28-17.
BLD - BUILDING FINAL 01/10/2018 FINAL APPROVED CMINI
ROW - FINAL INSPECTION 01/09/2018 APPROVED - AS NOTED RGROSS
Note: THIS IS A REINSPECTION. ADA MAT TO BE INSTALLED AT THE CORNER.
U -UTILITY RESIDENTIAL FINAL 01/08/2018 FINAL APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION-reuse now connected PLEASE REMOVE EXCESS SOILS FROM WATER METER PIT
ROW - FINAL APRON (AFTER POUR) 01/08/2018 APPROVED RGROSS
Note: THIS IS A REINSPECTION
ROW - FINAL INSPECTION 01/08/2018 Disapproved -FEE REQUIRED RGROSS
Note: ADA MAT NEEDED FROM SIDEWALK TO STREET TRANSITION
ROW- PRE-APRON (PRE-POUR) 01/05/2018 APPROVED - AS NOTED RGROSS
Note: THIS IS A REINSPECTION. SECOND PART OF THE PRE POUR. INSPECTED THE DAY BEFORE. READY FOR PAVERS.
ROW - FINAL APRON (AFTER POUR) 01/03/2018 Disapproved -FEE REQUIRED RGROSS
Note: FINAL APPROVED SURVEY NOT ON SITE. SECOND PART OF THE PRE POUR NEEDS TO BE APPROVED BEFORE FINAL APRON.
U -UTILITY RESIDENTIAL FINAL 01/03/2018 CANCELLED BY APPLICANT LFITZGERALD
Note: re-use meter not yet connected to home irrigation line,plumber not on site ; reminded builder supervisor to remove excess soils in water meter pit
FINAL SURVEY (OFFICE USE ONLY) 01/03/2018 Disapproved - NO FEE CMINI
Note: need to submit to office, not a call in inspection
ELECTRIC - EARLY POWER 11/30/2017 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED EARLY POWER 3:30
ROW- PRE-APRON (PRE-POUR) 10/16/2017 PARTIALLY APPROVED RGROSS
Note: APPROVED FOR SIDEWALK AND APRON POUR ONLY.
INSULATION 08/10/2017 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 08/10/2017 APPROVED DROCKWELL
INSULATION 08/09/2017 Disapproved -FEE REQUIRED DROCKWELL
Note: Fireblock archway/Fireblock all drop ceilings/Firefoam service panel and all penetrations thru top plate
ALL ROUGH 08/02/2017 APPROVED - AS NOTED CMINI
Note: fireblocking FBC 302. minimize gaps in door jams
ALL ROUGH 08/01/2017 CANCELLED BY APPLICANT AIRS WEB
TIE BEAM / LINTEL 07/28/2017 APPROVED - AS NOTED CMINI
Note: pool house completion
GAS ROUGH 07/24/2017 APPROVED CMINI
ROOF VALLEY & METAL 07/21/2017 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/20/2017 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/14/2017 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION. trusses not strapped at entry, need revision for arch window headers
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/12/2017 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION. need to see straps on headers front entry. missing headers over windows per detail. need to remove plywood showing kneewall
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/20/2017 Disapproved -FEE REQUIRED CMINI
Note: missing straps, missing headers, missing kneewalls, need repair revision for cut truss. LVLs not complete per plan. remove plywood on arches so we can see tie downs. remove soffits for inspection. not ready, incomplete inspection
ELECTRIC-TUG 05/25/2017 APPROVED - AS NOTED CMINI
Note: SPOKE TO DELL FPL RELEASED TUG 1:20
ROOF VALLEY & METAL 05/25/2017 Disapproved - NO FEE CMINI
Note: need to have roof sheathing, braces, ties and down cell approved before this inspection
TIE BEAM / LINTEL 03/21/2017 APPROVED CMINI
FOUND SURVEY APPROVED (OFFICE) 03/09/2017 APPROVED JHINDMAN
MONOLITHIC SLAB 03/07/2017 APPROVED LMILLER
PLUMBING 1ST ROUGH UNDERGROUND 03/03/2017 APPROVED CMINI
GRAVITY SEWER TEST 03/03/2017 APPROVED CMINI
U - SEWER TIE IN 03/03/2017 APPROVED JNICHOLS
FOOTER 02/10/2017 APPROVED CMINI

Review History

Department Status Date In Date Out
SW1 COMPLETE 12/22/2017 12/28/2017
Note: Released By: JHINDMAN final survey cannot complete inspection due to invalid NOC
BLD COMPLETE 12/22/2017 12/22/2017
Note: Released By: JHINDMAN
BLD COMPLETE 07/10/2017 07/10/2017
Note: Released By: JHINDMAN
BLD COMPLETE 06/19/2017 06/20/2017
Note: Released By: JHINDMAN
BLD HOLD 06/09/2017 06/12/2017
Note: Held By: JHINDMAN 1. Provide revised energy calculations and manufacturers specifications for the spray foam with the ignition barrier. 5th ed. FBC 107.2.1.
BLD COMPLETE 06/06/2017 06/08/2017
Note: Released By: JHINDMAN
SW1 COMPLETE 03/08/2017 03/09/2017
Note: Released By: JHINDMAN FOUNDATION S
PLUM COMPLETE 01/18/2017 01/23/2017
ZON COMPLETE 01/04/2017 01/05/2017
URB COMPLETE 01/04/2017 01/09/2017
ELEC COMPLETE 01/04/2017 01/12/2017
PLUM HOLD 01/04/2017 01/11/2017
Note: Repeat comment: Sanitary riser diagram does not match with floor plan. Washing machine and laundry tub drains were shown twice on riser. Coordinate per FBC 5th ed. 107.2.1. F.Reodica - 386-986-4734.
URB HOLD 12/20/2016 12/21/2016
Note: Need to add 1 street tree. The approved street tree plan shows 4 street trees for this lot 2 Live oak. 1 Laurel oak and 1 Drake elm. Also note street tree planting must be minimum 5ft from all curbs, sidewalks, driveways and utilities. spacing 50ft on center with a maximum 12ft 6in. from the ROW.
BLD COMPLETE 12/19/2016 12/21/2016
ELEC HOLD 12/19/2016 12/21/2016
Note: 1. Provide electrical load calculations per 2011 NEC art. 220. J. Hindman 986-3784.
ENGIN1 COMPLETE 12/19/2016 12/20/2016
MECH COMPLETE 12/19/2016 12/22/2016
PLUM HOLD 12/19/2016 12/22/2016
Note: Sanitary riser diagram does not match with floor plan. Washing machine and laundry tub drains were shown twice on riser. Coordinate per FBC 5th ed. 107.2.1. F.Reodica - 386-986-4734.
SW1 COMPLETE 12/19/2016 12/22/2016
UD1 COMPLETE 12/19/2016 12/20/2016
Note: This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON HOLD 12/19/2016 12/20/2016
Note: 1) Address issue. Can't finish zoning review 2) Landscaping : *REQUIRED SCREENING: Above ground structures such as: dumpster enclosures, mechanical equipment, backflow preventers, wells, pumps, tanks, ground-mounted HVAC units, transformers, generators, storage sheds, lift stations, utility cabinets, electrical panels, or ground-mounted cable/satellite television equipment; shall have a medium screen planting, as described in Table 11-4. If the structures are in areas that are visible from an improved public rights-of-way, a medium screen planting as described in Table 11-4 (**see excerpt from table below) shall be provided between the structures and the rights-of-way. If the structures are in areas that are visible from a parking lot or abutting property without an intervening buffer, fence, or wall, then a medium screen planting, as described in Table 11-4, shall be provided between the structures and the parking lot or abutting property. (LDC 11.03.01.H.) **From Table 11-4: (Medium screen planting) shrubs 2 ½’ in height, 7-gallon container, and maximum 4’ on-center spacing. Shrubs shall achieve a minimum height of 3’ within 2 years. REQUIRED PLANTINGS: Residential homes shall provide foundation plantings consisting of sixteen (16) shrubs. On interior lots, eight (8) shrubs shall be planted in front of the home, and four (4) shrubs planted on each side of the home. On corner lots, six (6) shrubs shall be planted on each side of the home facing a street, and (4) shrubs planted on the interior side of the home. All of these required shrubs shall be planted between two and one-half (2 ½) and eight (8) feet of the home’s foundation. The corners of the house shall be wrapped with shrubbery or have an understory tree planted there. (LDC 11.03.02.D.2.a,b,c) T Williams 386-986-2655

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 01/08/2018
REINSPECTION FEE ¤40.00 01/08/2018
REVISION ¤40.00 12/29/2017
REVISION ¤40.00 10/23/2017
REVISION ¤40.00 10/23/2017
REVISION ¤40.00 10/23/2017
REINSPECTION FEE ¤40.00 10/23/2017
REINSPECTION FEE ¤40.00 10/23/2017
REINSPECTION FEE ¤40.00 10/23/2017
REINSPECTION FEE ¤40.00 10/23/2017
NEW RESIDENTIAL INSPECTIONS ¤750.00 01/26/2017
ADMIN FEE ¤20.00 01/26/2017
ELECTRIC FEE ¤285.00 01/26/2017
3% FIRE IMPACT FEE CREDIT (¤6.43) 01/26/2017
IMPACT FEE FIRE NONRESIDENTIAL ¤214.29 01/26/2017
IMPACT FEE PARKS ¤849.24 01/26/2017
IMPACT FEE SCHOOL ¤3,600.00 01/26/2017
IMPACT FEE TRANSPORTATION ¤3,124.67 01/26/2017
MECHANICAL FEE ¤285.00 01/26/2017
3% PARKS IMPACT FEE CREDIT (¤25.48) 01/26/2017
PLAN CHECK FEE ¤150.00 01/26/2017
PLUMBING FEE ¤285.00 01/26/2017
SITE PLAN 20 ¤20.00 01/26/2017
SURCHARGE FS 533.721 ¤26.93 01/26/2017
SURCHARGE - FS 468.631 ¤26.93 01/26/2017
STORM WATER PERMIT FEES ¤80.00 01/26/2017
3% TRANS IMPACT FEE CREDIT (¤93.74) 01/26/2017
Fees Total Due: ¤0.00 Total Paid: ¤9,991.41