I want to search for...
Permit #2017010397
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7034-01110-0020 |
| Block: 01110 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: 386-445-6752 |
| Location Address: 76 ERIC DR |
| Type: PO - POOL |
| Issue Date: 01/25/2017 |
| NOC: RECORDED |
| Applicant name: ROMINA CYNTHIA CAMPELLO DE LONGO |
| Owner: NAVARRO, EVANGELISTA |
|
Address 76 ERIC DR PALM COAST, FL 32164 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤30,000.00 |
| Job Description: INGROUND POOL & FENCE |
| Type: CN |
Contractor
CRYSTAL CLEAR POOLCLEANING OF CENTRAL FLORIDA, INC
| Status | Location Address | State License Number | Phone |
| CANCEL |
56 FRENEAU LANE PALM COAST, FL 32137 |
CPC1458734 (Exp: 08/31/2020) | 386-445-6752 |
Sub Contractors
JESSE E MORRIS
| Status | Location Address | State License Number | Phone |
| INACTIVE |
60 COPPER LANE PALM COAST, FL 32137 |
EC13007529 (Exp: 08/31/2018) | 847-815-2885 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW DAMAGE | 10/13/2017 | APPROVED | CTROHA |
| Note: MEETS REQUIREMENTS AT TIME OF THE INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | 10/13/2017 | FINAL APPROVED | MBACON |
| FINAL SURVEY (OFFICE USE ONLY) | 08/08/2017 | Disapproved - NO FEE | FREODICA |
| Note: Grading elevations at the back corners of the pool show low spots where surfsce drain water flows to foundation wall which are prohibited per FBCR 5th ed. R401.3. F.Reodica -386-986-4734. | |||
| ELECTRIC AND ALARM | 06/20/2017 | APPROVED | CMINI |
| POOL DECK | 03/23/2017 | APPROVED | CMINI |
| STEEL AND GROUND | 02/17/2017 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| STEEL AND GROUND | 02/16/2017 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: System not holding pressure.Less than 10lb psi on gauge | |||
| FINAL SURVEY (OFFICE USE ONLY) | |||
| Note: THIS IS A REINSPECTION | |||
| POOL FINAL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | HOLD | 08/03/2017 | 08/08/2017 |
| Note: Held By: FREODICA FINAL S Grading elevations at the back corners of the pool show low spots where surfsce drain water flows to foundation wall which are prohibited per FBCR 5th ed. R401.3. F.Reodica -386-986-4734. | |||
| ZON | COMPLETE | 01/20/2017 | 01/23/2017 |
| BLD | COMPLETE | 01/20/2017 | 01/25/2017 |
| BLD | HOLD | 01/11/2017 | 01/19/2017 |
| Note: 1. Identify the location of the barrier fence 5th ed. FBC R 4501.17. J. Hindman 986-3784. | |||
| SW1 | COMPLETE | 01/11/2017 | 01/19/2017 |
| ZON | HOLD | 01/11/2017 | 01/11/2017 |
| Note: Need to show location of fence and the type/material of fence | |||
| SW1 | CANCEL |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN FEE | ¤20.00 | 01/25/2017 |
| PERMIT FEE | ¤160.00 | 01/25/2017 |
| PLAN CHECK FEE | ¤40.00 | 01/25/2017 |
| SITE PLAN 20 | ¤20.00 | 01/25/2017 |
| SURCHARGE FS 533.721 | ¤3.60 | 01/25/2017 |
| SURCHARGE - FS 468.631 | ¤3.60 | 01/25/2017 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/25/2017 |
| REINSPECTION FEE | ¤40.00 | |
| Fees | Total Due: ¤40.00 | Total Paid: ¤327.20 |