Permit #2017010707
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7037-01620-0060 |
| Block: 01620 |
| Subdivision: 2176 - SECTION 37-LAKEVIEW |
| Job Phone: (386) 446-3615 |
| Location Address: 163 LONDON DR |
| Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION |
| Issue Date: 01/31/2017 |
| NOC: RECORDED |
| Applicant name: RICHARD W HAUSEN |
| Owner: CAYOUETTE, NAPOLEON JR & NANCY |
|
Address 163 LONDON DRIVE PALM COAST, FL 32137 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤6,500.00 |
| Job Description: REMODEL KITCHEN |
| Type: CN |
Contractor
HAUSEN PROPERTIES INC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P. O. BOX 351868 Palm Coast, FL 32135 |
RG0029505 (Exp: 08/31/2025) | (386) 446-3615 | 386-446-3615 |
Sub Contractors
DAVID L MILLER
| Status | Location Address | State License Number | Phone |
| CANCEL |
170 OLD MOODY BLVD BUNNELL, FL 32110 |
CFC1425948 (Exp: 08/31/2022) | (386) 439-2169 |
EDDY HUTTO
| Status | Location Address | State License Number | Phone |
| INACTIVE |
61 RYMSHAW DRIVE PALM COAST, FL 32164 |
ES12000255 (Exp: 08/31/2022) | 386-793-6778 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 03/31/2017 | FINAL APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 02/14/2017 | Disapproved - NO FEE | JCOLASANTI |
| Note: called wrong inspection, need to call monolithic inspection for tomorrow | |||
| INSULATION | 02/08/2017 | APPROVED | JCOLASANTI |
| ALL ROUGH | 02/06/2017 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB | 02/06/2017 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 02/02/2017 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: NEED TWO NAIL PLATES EACH SIDE WHERE UNDERGROUND CONDUIT MEETS THE WALL....MOVE CONDUCTORS 1 1/4" FROM FURRING STRIPS.....FIREBLOCKING NEEDED 26..F.B.C. 302.11 (FIREBLOCK CEILING OPENING TO ATTIC AT NEW KNEE WALL IN KITCHEN) | |||
| ELECTRIC UNDERGROUND | 02/02/2017 | APPROVED | RMARTIN |
| MONOLITHIC SLAB | 02/02/2017 | Disapproved - NO FEE | JCOLASANTI |
| Note: NEED TO INSTALL MIN 6MILL VAPOR BARRIER |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 01/25/2017 | 01/30/2017 |
| BLD | COMPLETE | 01/18/2017 | 01/23/2017 |
| ELEC | HOLD | 01/18/2017 | 01/23/2017 |
| Note: 1. Identify the GFCI receptacle spacing for the island and the counters. 2011 NEC 210.52. J. Hindman 986-3784. | |||
| PLUM | COMPLETE | 01/18/2017 | 01/23/2017 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 02/13/2017 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 01/31/2017 |
| SITE PLAN 20 | ¤20.00 | 01/31/2017 |
| SURCHARGE FS 533.721 | ¤3.73 | 01/31/2017 |
| SURCHARGE - FS 468.631 | ¤3.73 | 01/31/2017 |
| ADMIN FEE | ¤20.00 | 01/31/2017 |
| ELECTRIC FEE | ¤64.20 | 01/31/2017 |
| PLAN CHECK FEE | ¤40.00 | 01/31/2017 |
| PLUMBING FEE | ¤64.20 | 01/31/2017 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤295.86 |