Permit #2017030487
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7016-00010-0030 |
| Block: 00010 |
| Subdivision: 2201 - SECTION 16-COUNTRY CLUB COVE |
| Job Phone: 386-547-8383 |
| Location Address: 6 COLECHESTER LN |
| Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION |
| Issue Date: 04/03/2017 |
| NOC: RECORDED |
| Applicant name: MICHAEL P CANNON |
| Owner: STEVENS MARK & LISA CLOSE JTWROS |
|
Address 6 COLESCHESTER LANE PALM COAST, FL 32137 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤22,819.00 |
| Job Description: CONVERT SCREEN ROOM INTO LIVING SPACE |
| Type: CN |
Contractor
CANNON HOME SERVICES INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
39 PUTTER DR PALM COAST, FL 32164 |
CBC1259826 (Exp: 08/31/2026) | 386-547-8383 |
Sub Contractors
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 08/25/2017 | FINAL APPROVED | CMINI |
| INSULATION | 05/30/2017 | APPROVED | CMINI |
| LATH/BRICK/ WATER BARRIER | 05/26/2017 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 05/25/2017 | Disapproved - NO FEE | CMINI |
| Note: NEED TO INSTALL WEEP SCREED AT BOTTON OF LATH PER FBC 703.6 AND ASTM STANDARD 926. STUCCO STOP IS NOT ALLOWED WHEN FRAMED WALL IS ATTACHED TO FOUNDATION. ALSO WHERE THE RIGHT SIDE DIES INTO EXISTING HOUSE NEED TO HAVE STUCCO STOP AT THAT AREA SO IT DOES NOT CRACK PER ASTM STANDARD. THE SEPARTE WINDOW NEEDS ATTENTION AT BOTTOM IF IT IS WOOD FRAME TO GRADE | |||
| ALL ROUGH | 05/17/2017 | APPROVED - AS NOTED | LMILLER |
| Note: MISSING SWITCH AND LIGHT AT EXTERIOR DOOR, OCCUPANT STATED SHE TOLD YOU THAT SHE DIDNT WANT THE LIGHT BECAUSE SHE ALREADY HAD A LIGHT AT THE DOOR BISIDE IT ON THE BACK OF HOST STRUCTURE. IT IS OK TO OMIT THE LIGHT BUT YOU MUST ADD A SWITHC TO CONTROL THE LIGHT AT THE BACK OF HOST STRUCTURE IN ORDER TO MEET CODE.... EXTERIOR DOOR LIGHTS 26. EACH EXTERIOR DOOR SHALL HAVE A LIGHT AND SWITCH R 3903.3 (MUST HAVE BY INSULATION INSPECTION) ALSO NEED REVISION ON EADDED AND OMITTED ELECTRIC BY FINAL. | |||
| WALL SHEATHING | 05/04/2017 | APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION | |||
| WALL SHEATHING | 05/02/2017 | Disapproved -FEE REQUIRED | LMILLER |
| Note: STRAPS NOT AS PROPOSED ON PLANS (CIRCLED ON PLANS) |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 05/19/2017 | 05/23/2017 |
| ELEC | COMPLETE | 03/30/2017 | 03/31/2017 |
| MECH | COMPLETE | 03/30/2017 | 03/31/2017 |
| ELEC | HOLD | 03/29/2017 | 03/29/2017 |
| Note: 1. Provide an electrical contractor for the new electric. F.S.S. 489. J. Hindman 986-3784. | |||
| MECH | HOLD | 03/29/2017 | 03/29/2017 |
| Note: 1. The proposed space does not meet the classification of a sunroom by definition per FBCR 5th edition. It is a building addition. 2. Clarify if the existing space has provided with heating/cooling as shown on plan per FBC 5th ed. 107.2.1. F.Reodica -386-986-4734. | |||
| BLD | COMPLETE | 03/29/2017 | 03/29/2017 |
| ZON | COMPLETE | 03/29/2017 | 03/29/2017 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 05/24/2017 |
| REINSPECTION FEE | ¤40.00 | 05/03/2017 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 04/03/2017 |
| ADMIN FEE | ¤20.00 | 04/03/2017 |
| ELECTRIC FEE | ¤73.80 | 04/03/2017 |
| PLAN CHECK FEE | ¤40.00 | 04/03/2017 |
| SITE PLAN 20 | ¤20.00 | 04/03/2017 |
| SURCHARGE FS 533.721 | ¤2.91 | 04/03/2017 |
| SURCHARGE - FS 468.631 | ¤2.91 | 04/03/2017 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤279.62 |