Status: STATE
| Parcel Id: 07-11-31-7059-00120-0030 |
| Block: 00120 |
| Subdivision: 2211 - SECTION 59-SEMINOLE PARK |
| Job Phone: 407-871-2020 |
| Location Address: 21 SEA SPIRAL PATH |
| Type: PO - POOL |
| Issue Date: 05/09/2017 |
| NOC: RECORDED |
| Applicant name: JOHN NICHOLAS WATTS |
| Owner: LUHTA PATRICIA RUDMAN & HAROLD RAY MCEWEN |
|
Address 21 SEA SPIRAL PATH PALM COAST, FL 32164 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤58,800.00 |
| Job Description: POOL W/SCREEN ENCLOSURE W/ELITE ROOF & SPA |
| Type: CN |
Contractor
ALL SEASONS POOL SERVICE INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
185 E AIRPORT BLVD GENEVA , FL 32732 |
CPC023576 (Exp: 08/31/2026) | 407-871-2020 | 407-321-5404 |
Sub Contractors
DAVID THOMAS PRUETTE
| Status | Location Address | State License Number | Phone |
| ACTIVE |
331-8 PARKRIDGE AVE ORANGE PARK , FL 32065 |
EC0002923 (Exp: 08/31/2026) | 904-272-7225 |
ROBERT F GARVEY
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
650 HICKMAN CIR SANFORD, FL 32771 |
SCC131151598 (Exp: 08/31/2026) | 407-703-2500 | 407-703-2501 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW DAMAGE | 02/23/2018 | Disapproved -FEE REQUIRED | CTROHA |
| Note: NEED TO SOD SWALE AND MATCH EXISTING GRADE ALSO FINAL SURVEY MUST BE APPROVED BEFORE THIS INSPECTION IS CALLED IN | |||
| FINAL SURVEY (OFFICE USE ONLY) | 12/20/2017 | Disapproved - NO FEE | CMINI |
| Note: THIS IS A REINSPECTION..need to submit to office, not a call in inspection | |||
| ROW DAMAGE | 12/20/2017 | Disapproved - NO FEE | CTROHA |
| Note: YOU NEED YOUR FINAL SURVEY APPROVED AND ON SITE FOR THIS INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | 12/20/2017 | FINAL APPROVED | MBACON |
| Note: THIS IS A REINSPECTION | |||
| FINAL SURVEY (OFFICE USE ONLY) | 12/11/2017 | Disapproved - NO FEE | CMINI |
| Note: need to submit to office, not a call in inspection | |||
| ROW - DRAINAGE | 11/01/2017 | Disapproved -FEE REQUIRED | CTROHA |
| Note: JOB NOT COMPLETE SEE PERVIOUS NOTES | |||
| ROW DAMAGE | 10/30/2017 | Disapproved - NO FEE | CTROHA |
| Note: WORK NOT COMPLETED NEED SOD AND REGRADE | |||
| U -UTILITY RESIDENTIAL FINAL | 10/30/2017 | Disapproved - NO FEE | JNICHOLS |
| Note: THIS IS A REINSPECTION | |||
| ROW DAMAGE | 10/26/2017 | Disapproved -FEE REQUIRED | CTROHA |
| Note: THE SWALE IS FULL OF BASE MATERIAL BLOCKING THE SWALE IT NEEDS TO BE REMOVED AND CULVERT PIPE NEEDS CLEANED OUT SOD AND AREAS IN THE RIGHT OF WAY THAT NEDDS IT MATCH EXISTING GRADE AND SOD TYPE | |||
| U -UTILITY RESIDENTIAL FINAL | 10/26/2017 | Disapproved - NO FEE | MBACON |
| Note: Job is not complete. Call in after all cleanup is complete. | |||
| ELECTRIC AND ALARM | 10/24/2017 | APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION | |||
| ELECTRIC AND ALARM | 10/23/2017 | CANCELLED BY APPLICANT | RMARTIN |
| Note: THIS IS A REINSPECTION | |||
| ELECTRIC AND ALARM | 10/18/2017 | Disapproved - NO FEE | RMARTIN |
| Note: THIS IS A REINSPECTION ALARMS GOOD NEED BONDING ON SCREEN ENCLOSURE NEC 680.26 | |||
| ELECTRIC AND ALARM | 10/16/2017 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: No one home to check alarms | |||
| POOL DECK | 08/31/2017 | APPROVED | DROCKWELL |
| STEEL AND GROUND | 06/23/2017 | APPROVED | DROCKWELL |
| FINAL SURVEY (OFFICE USE ONLY) | |||
| Note: THIS IS A REINSPECTION | |||
| POOL FINAL | |||
| ROW DAMAGE | |||
| Note: THIS IS A REINSPECTION |
Review History
| Department | Status | Date In | Date Out |
| SW1 | HOLD | 05/21/2018 | 05/21/2018 |
| Note: Held By: DREWIS Provide survey elevations depicting drainage. Daniel Rewis 986-4736 | |||
| SW1 | HOLD | 12/05/2017 | 12/07/2017 |
| Note: Held By: DREWIS final s Please provide survey measurements depicting flow. Daniel Rewis 986-4736 | |||
| BLD | COMPLETE | 05/04/2017 | 05/05/2017 |
| BLD | HOLD | 04/28/2017 | 05/02/2017 |
| Note: 1. Provide the correct pipe size and friction factor for the return piping per the Flow and Friction Loss Per Foot Chart. (10 fps at 90gpm= 2in pipe with a .16 friction factor.) (Your chart does not show the friction factor at 10fps).5th ed. FBC R 4501.6.1. J. Hindman 986-3784 | |||
| ZON | COMPLETE | 04/04/2017 | 04/04/2017 |
| BLD | HOLD | 04/04/2017 | 04/04/2017 |
| Note: 1. Provide the correct minimum pipe sizes and friction factors for the determine simplified TDH sections of the worksheet. Pipe sizes and Friction factors need to be based off of the 90 GPM.. These are minimum sizes.). 5th ed. FBC R 4501.6.1. J. Hindman 986-3784 | |||
| SW1 | COMPLETE | 04/04/2017 | 04/04/2017 |
| BLD | HOLD | 03/24/2017 | 03/27/2017 |
| Note: 1. Provide the correct minimum pipe sizes and friction factors for the determine simplified TDH sections of the worksheet. (The system flow rate should be 90 GPM based on your calculations. Pipe sizes and Friction factors need to be based off this number. These are minimum sizes.). 5th ed. FBC R 4501.6.1. J. Hindman 986-3784. | |||
| SW1 | HOLD | 03/24/2017 | 03/27/2017 |
| Note: 1. Identify the proposed lot drainage. ch.5 ULDC Tech Manual. J. Hindman 986-3784. | |||
| ZON | HOLD | 03/24/2017 | 03/24/2017 |
| Note: Site plan needs to show rear setback of a min 6.5' from pool deck to property line | |||
| SW1 | CANCEL |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 02/27/2018 |
| REINSPECTION FEE | ¤40.00 | 11/07/2017 |
| REINSPECTION FEE | ¤40.00 | 11/07/2017 |
| REINSPECTION FEE | ¤40.00 | 10/17/2017 |
| ADMIN FEE | ¤20.00 | 05/09/2017 |
| PERMIT FEE | ¤160.00 | 05/09/2017 |
| PLAN CHECK FEE | ¤40.00 | 05/09/2017 |
| SITE PLAN 20 | ¤20.00 | 05/09/2017 |
| SURCHARGE FS 533.721 | ¤3.60 | 05/09/2017 |
| SURCHARGE - FS 468.631 | ¤3.60 | 05/09/2017 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/09/2017 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤487.20 |