Permit #2017031225

Permit Details

Status: COED

Parcel Id: 33-11-31-3061-00010-0110
CONDITIONED SPACE: 2443 sqft
CONDITIONED SPACE: 269 sqft
GARAGE: 499 sqft
OPENED PORCH (WITH ROOF) : 91 sqft
OPENED PORCH (WITH ROOF) : 442 sqft
Total Square Footage: 3744 sqft
Block: 00010
Subdivision: 2108 - Hidden Lakes- Phase II-Toscana
Job Phone: 863-420-2100
Location Address: 21 NEW LEATHERWOOD DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/24/2017
NOC: RECORDED
Applicant name: YUVAL BOTANSKY
Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC

Address

131 CHADWICK DRIVE

DAVENPORT, FL 33837

Lot: 0110
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

APPLIED BUILDING DEVELOPMENT COMPANY - OAKHILLS IN
Status Location Address State License Number Phone Fax
ACTIVE

131 CHADWICK DRIVE

DAVENPORT, FL 33837

CRC1330762 (Exp: 08/31/2026) 863-420-2100 386-517-6865

Sub Contractors

JOSEPH H STRADA JR
Status Location Address State License Number Phone Fax
CANCEL

531 CODISCO WAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2018) (407)333-2665 (407)585-1002
TERRY HILE BURD
Status Location Address State License Number Phone Fax
INACTIVE

PO Box 180308

CASSELBERRY, FL 32707

CAC1814423 (Exp: 08/31/2024) (407) 831-3600 (407)831-2893
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/05/2018 FINAL APPROVED CMINI
ROW - FINAL INSPECTION 03/05/2018 APPROVED - AS NOTED KHOWELL
Note: TOLD MASON TO ADD SOD AND DIRT AT THE END OF THE SIDEWALK AND I WOULD COME BACK BY DURING THE NEXT INSPECTION TO MAKE SURE IT HAS BEEN DONE
ROW - FINAL APRON (AFTER POUR) 03/02/2018 APPROVED - AS NOTED KHOWELL
Note: CONTRACTOR SHALL VERIFY THAT THE WATER WILL DRAIN FROM THE SIDEWALK TO THE CURB
U -UTILITY RESIDENTIAL FINAL 03/01/2018 FINAL APPROVED LFITZGERALD
Note: as discussed and AGREED with new ABD close out rep. Mason and also with Frank and Josh of ABD, the water meter pit needs to be flush with the sod grade around it AND the excessive soils in both the water meter pit and reclaim meter pit removed. i informed all that another inspection will be prformed sometime next week to ensure that these conditions were met. i also explained to Mason and Frank that if there seems to be an issue with the water meter pit height at the start of construction, to call the city utility dept. so it can be addressed before the FINAL is called in.
ROW - FINAL INSPECTION 03/01/2018 Disapproved - NO FEE KHOWELL
Note: SOD NOT INSTALLED AT TIME OF INSPECTION
U-CROSS CONNECTION 03/01/2018 APPROVED LFITZGERALD
ROW - FINAL APRON (AFTER POUR) 03/01/2018 Disapproved -FEE REQUIRED KHOWELL
Note: SOD NOT INSTALLED AT TIME OF INSPECTION
FINAL SURVEY (OFFICE USE ONLY) 02/23/2018 APPROVED DREWIS
ROW - FINAL APRON (AFTER POUR) 02/16/2018 Disapproved -FEE REQUIRED RGROSS
Note: Edges Of Driveway Not Stabilized
TUB SET 02/15/2018 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
TUB SET 02/14/2018 Disapproved -FEE REQUIRED CMINI
Note: need to fill tub for test
PRE-POUR 02/13/2018 APPROVED - AS NOTED RGROSS
Note: THIS WAS FOR A PAVER DRIVEWAY. SUPER PUT WRONG CODE. SUPER SPOKEN TO ABOUT CORRECT CODE INSPECTIONS.
ELECTRIC - EARLY POWER 02/09/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 3:30
ROW- PRE-APRON (PRE-POUR) 02/08/2018 PARTIALLY APPROVED RGROSS
Note: THIS IS A REINSPECTION. APPROVED FOR SIDEWALK AND DRIVEWAY APRON POUR ONLY. SECOND PRE POUR NEEDED WHEN SUB BASE IS DOWN AND COMPACTED BUT BEFORE PAVERS ARE PLACED.
ROW- PRE-APRON (PRE-POUR) 02/05/2018 Disapproved -FEE REQUIRED CTROHA
Note: NOT READY FOR INSPECTION NO PREP HAS BEEN DONE FOR PREPOUR
U - SEWER TIE IN 01/18/2018 FINAL APPROVED LFITZGERALD
ELECTRIC-TUG 01/18/2018 APPROVED CMINI
Note: THIS IS A REINSPECTION
GRAVITY SEWER TEST 01/18/2018 APPROVED CMINI
INSULATION 12/22/2017 APPROVED CMINI
Note: THIS IS A REINSPECTION
INSULATION 12/18/2017 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION. can not conduct full inspection, drywall still covering areas, need to remove all. do not call in again untill corrected. also missing energy calcs
LATH/BRICK/ WATER BARRIER 12/15/2017 APPROVED CMINI
INSULATION 12/15/2017 CANCELLED BY APPLICANT CMINI
Note: THIS IS A REINSPECTION
INSULATION 12/14/2017 CANCELLED BY APPLICANT AIRS WEB
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 12/13/2017 CANCELLED BY APPLICANT AIRS WEB
LATH/BRICK/ WATER BARRIER 12/12/2017 CANCELLED BY APPLICANT AIRS WEB
INSULATION 12/12/2017 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION. need to uncover all work covered by drywall
INSULATION 12/11/2017 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION. missing gas riser per notes, need to remove drywall for proper inspection.
ELECTRIC-TUG 12/07/2017 Disapproved -FEE REQUIRED RMARTIN
Note: NEED PROPER GROUNDING PER NEC 250.20 AND PER PLAN
INSULATION 12/06/2017 CANCELLED BY APPLICANT CMINI
Note: THIS IS A REINSPECTION
INSULATION 12/05/2017 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTIONneed to uncover to have access for inspection. C104.2
INSULATION 12/01/2017 Disapproved -FEE REQUIRED CMINI
Note: need to remove all drywall for insulation inspection
ALL ROUGH 11/16/2017 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION. missing gas riser, check on insulation
TIE BEAM / LINTEL 11/07/2017 APPROVED CMINI
ALL ROUGH 11/07/2017 Disapproved -FEE REQUIRED CMINI
Note: missing gas riser diagrahm. need to install floor outlet and bury pipe. missing outlet left hand of sink, kitchen..need to pase out all hot conductors in panel..fireblocking , entertainment and fireplace areas
ROOF VALLEY & METAL 11/01/2017 APPROVED CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/31/2017 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/30/2017 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION.. piggy backs missing connection. missi ng engineering pack..missing strap on truss on bearing wall in garage. need to sit truss completely into bucket in courtyard
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/24/2017 Disapproved -FEE REQUIRED CMINI
Note: checked front entry straps only, ok to cover. not ready on rest of house
TIE BEAM / LINTEL 07/14/2017 APPROVED CMINI
MONOLITHIC SLAB 06/20/2017 APPROVED CMINI
FOUND SURVEY APPROVED (OFFICE) 06/12/2017 APPROVED JHINDMAN
PLUMBING 1ST ROUGH UNDERGROUND 06/06/2017 APPROVED - AS NOTED JGIBSON
Note: NEED REVISION TO SHOW SEWER MAIN EXITING TWICE OUT OF POOL BATH SEPERATELY AND NEED TO LIST CORRECT PLUMBING SUB CONTRACTOR
FOOTER 05/05/2017 APPROVED LMILLER
Note: THIS IS A REINSPECTION
FOOTER 05/04/2017 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION STANDARD HOOKS R404.1.2.3.7.7 AND 611.5.4.5 AND FIGURE 611.5.4(3) NEED TO USE PROPER HOOKS FOR REINFORCEMENT
FOOTER 05/03/2017 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION CLEARANCE ON REBAR FROM EARTH 3 1D FBC R404.1.2.3.7.4AND MISSING VERTICLE ROD (ALL MARKED ON PLANS)
FOOTER 05/01/2017 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION 12 inch MINIMUM DEPTH , UNDISTURBED GROUND SURFACE 26 R403.1.3.4 and in accordance with 401.2 and 403.1 ALL FOOTINGS SHALL BE PLACED AT LEAST 12 in. BELOW THE UNDISTURBED GROUND SURFACE CLEARANCE ON REBAR FROM EARTH 3 1D FBC R404.1.2.3.7.4
FOOTER 04/28/2017 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION NO COMPACTION REPORT FOR PAD ON SITE 12 inch MINIMUM DEPTH , UNDISTURBED GROUND SURFACE 26 R403.1.3.4 and in accordance with 401.2 and 403.1 ALL FOOTINGS SHALL BE PLACED AT LEAST 12 in. BELOW THE UNDISTURBED GROUND SURFACE
FOOTER 04/27/2017 Disapproved -FEE REQUIRED LMILLER
Note: 12 inch MINIMUM DEPTH , UNDISTURBED GROUND SURFACE 26 R403.1.3.4 and in accordance with 401.2 and 403.1 ALL FOOTINGS SHALL BE PLACED AT LEAST 12 in. BELOW THE UNDISTURBED GROUND SURFACE

Review History

Department Status Date In Date Out
SW1 COMPLETE 02/22/2018 02/23/2018
Note: Released By: DREWIS final s
PLUM COMPLETE 12/06/2017 12/08/2017
Note: Released By: JHINDMAN
PLUM HOLD 11/17/2017 11/30/2017
Note: Held By: JHINDMAN 1. The gas riser must have the contractors license number and signature on it. J. hindman 986-3784. 5th ed. FBC 107.1.
PLUM COMPLETE 06/22/2017 06/27/2017
Note: Released By: FREODICA Revision: changed sanitary riser diagram
PLUM HOLD 06/19/2017 06/20/2017
Note: Held By: FREODICA Revision: Riser Diagram Provide complete vent pipe sizes and clarify where is the pipe connection of the other bathroom group to the main sanitary line per FBC 5th ed. 107.2.1/FBCR 5th ed. P3101. F.Reodica - 386-986-4734..
SW1 COMPLETE 06/12/2017 06/12/2017
Note: Released By: JHINDMAN foundation s
BLD COMPLETE 06/06/2017 06/12/2017
Note: Released By: JHINDMAN
PLUM COMPLETE 04/17/2017 04/20/2017
BLD COMPLETE 03/29/2017 03/30/2017
ELEC COMPLETE 03/29/2017 03/30/2017
ENGIN1 COMPLETE 03/29/2017 03/30/2017
MECH COMPLETE 03/29/2017 03/30/2017
PLUM HOLD 03/29/2017 03/30/2017
Note: 1. Provide pipe size on sanitary riser diagram for powder room fixture branch drain per FBC 5th ed. 107.2.1. Freodica - 386-986-4734.
SW1 COMPLETE 03/29/2017 03/30/2017
UD1 COMPLETE 03/29/2017 03/31/2017
ZON COMPLETE 03/29/2017 03/30/2017

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 03/01/2018
REINSPECTION FEE ¤40.00 02/20/2018
REINSPECTION FEE ¤40.00 02/20/2018
REINSPECTION FEE ¤40.00 02/20/2018
REINSPECTION FEE ¤40.00 12/18/2017
REINSPECTION FEE ¤40.00 12/14/2017
REINSPECTION FEE ¤40.00 12/14/2017
REINSPECTION FEE ¤40.00 12/14/2017
REINSPECTION FEE ¤40.00 12/14/2017
REINSPECTION FEE ¤40.00 12/01/2017
REINSPECTION FEE ¤40.00 11/07/2017
REINSPECTION FEE ¤40.00 11/07/2017
REVISION ¤40.00 10/17/2017
REINSPECTION FEE ¤40.00 10/17/2017
REINSPECTION FEE ¤40.00 10/17/2017
REINSPECTION FEE ¤40.00 10/17/2017
REINSPECTION FEE ¤40.00 10/17/2017
REINSPECTION FEE ¤40.00 10/17/2017
REINSPECTION FEE ¤40.00 10/17/2017
ADDITIONAL FEE ¤40.00 10/17/2017
ADMIN FEE ¤20.00 04/24/2017
ELECTRIC FEE ¤265.80 04/24/2017
3% FIRE IMPACT FEE CREDIT (¤6.43) 04/24/2017
IMPACT FEE FIRE NONRESIDENTIAL ¤214.29 04/24/2017
IMPACT FEE PARKS ¤849.24 04/24/2017
IMPACT FEE SCHOOL ¤3,600.00 04/24/2017
IMPACT FEE TRANSPORTATION ¤3,124.67 04/24/2017
MECHANICAL FEE ¤265.80 04/24/2017
3% PARKS IMPACT FEE CREDIT (¤25.48) 04/24/2017
PLAN CHECK FEE ¤137.20 04/24/2017
PLUMBING FEE ¤265.80 04/24/2017
SITE PLAN 20 ¤20.00 04/24/2017
SURCHARGE FS 533.721 ¤24.91 04/24/2017
SURCHARGE - FS 468.631 ¤24.91 04/24/2017
STORM WATER PERMIT FEES ¤80.00 04/24/2017
3% TRANS IMPACT FEE CREDIT (¤93.74) 04/24/2017
NEW RESIDENTIAL INSPECTIONS ¤686.00 04/24/2017
Fees Total Due: ¤0.00 Total Paid: ¤10,252.97