Permit #2017031230
Permit Details
Status: COED
| Parcel Id: 07-11-31-7001-000B0-0020 |
| Total Square Footage: 6572 sqft |
| Block: 000B0 |
| Subdivision: 1238 - PALM HARBOR CENTER REPLAT |
| Job Phone: 954-825-8369 |
| Location Address: 24 OLD KINGS RD N |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 12/18/2017 |
| NOC: Unknown |
| Applicant name: THOMAS M SCAGLIONE |
| Owner: MANDEVILLE MANOR HEALTH SYSTEMS INC |
|
Address 40 PONCE DELEON DRIVE PALM COAST, FL 32164 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤17,000.00 |
| Job Description: UNIT A & B- "MANORVILLE MANOR HEALTH SYSTEM"ADULT DAYCARE |
| Type: CN |
Contractor
T-CON GROUP, INC.
| Status | Location Address | State License Number | Phone |
| CANCEL |
3246 NORTH POWERLINE ROAD POMPANO BEACH, FL 33069 |
CBC1251999 (Exp: 08/31/2020) | 954-825-8369 |
Sub Contractors
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
JAMES KUYKENDALL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2550 US 1 NORTH SUITE 3 BUNNELL, FL 32110 |
CAC1815546 (Exp: 08/31/2022) | (386)437-2929 | (386)437-2942 |
JAMES KUYKENDALL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2550 US 1 NORTH SUITE 3 BUNNELL, FL 32110 |
CAC1815546 (Exp: 08/31/2022) | (386)437-2929 | (386)437-2942 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 01/15/2019 | APPROVED | JHINDMAN |
| ELECTRIC FINAL | 01/15/2019 | APPROVED | RMARTIN |
| BUILDING FINAL | 01/15/2019 | APPROVED | JHINDMAN |
| FIRE FINAL | 01/15/2019 | APPROVED | JHINDMAN |
| U - UTILITY COMMERCIAL FINAL | 01/15/2019 | FINAL APPROVED | JNICHOLS |
| HVAC ROUGH | 12/11/2018 | APPROVED | JHINDMAN |
| ABOVE CEILING | 12/11/2018 | APPROVED | JHINDMAN |
| PLUMBING FINAL | 12/07/2018 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION GREASE INTERCEPTOR IN PLACE | |||
| PLUMBING FINAL | 10/18/2018 | Disapproved - NO FEE | JGIBSON |
| Note: PER REVISION UNDER ADDED 3 COMPARTMENT SINK GREASE INTERCEPTOR NOT IN AND NEED HI-LOW DRINKING FOUTAIN | |||
| MONOLITHIC SLAB | 08/23/2018 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| ELECTRIC 2ND ROUGH | 08/07/2018 | APPROVED | RMARTIN |
| PLUMBING 2ND ROUGH | 07/25/2018 | APPROVED | JGIBSON |
| PLUMBING 2ND ROUGH | 07/24/2018 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: DOOR LOCKED UNABLE TO GAIN ACCESS 10:47 AM | |||
| PLUMBING 2ND ROUGH | 07/20/2018 | Disapproved - NO FEE | JGIBSON |
| Note: TEST NOT HOLDING ON SECOND ROUGH TEST BALL ON SEWER IN REAR | |||
| ELECTRIC 1ST ROUGH | 07/20/2018 | APPROVED - AS NOTED | RMARTIN |
| Note: NO UNDERGROUND NEEDED, NEED TO CALL IN 2ND ROUGH WHEN APPROVED DRAWING IS ON SITE FOR WORK BEING DONE | |||
| FRAMING | 06/21/2018 | APPROVED | JHINDMAN |
| MONOLITHIC SLAB | 06/12/2018 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: no access building locked 6th ed. fbc 110.5 | |||
| PLUMBING 1ST ROUGH | 05/23/2018 | APPROVED - AS NOTED | JGIBSON |
| Note: NEED A REVISION TO SHOW CHANGE OF WATER PIPE used, cpvc speced ON PLANS UPANAR USED |
Review History
| Department | Status | Date In | Date Out |
| FI1 | COMPLETE | 09/28/2018 | 09/28/2018 |
| Note: Released By: LMUSGROVE j hindman | |||
| FI1 | HOLD | 09/20/2018 | 09/27/2018 |
| Note: Held By: JHINDMAN | |||
| FI1 | HOLD | 09/12/2018 | 09/12/2018 |
| Note: Held By: JHINDMAN 1. Provide a type 1 greese hood with a suppression system per nfpa96. J. hindman 986-3784. | |||
| BLD | COMPLETE | 08/29/2018 | 09/12/2018 |
| Note: Released By: JHINDMAN | |||
| ELEC | COMPLETE | 07/31/2018 | 08/02/2018 |
| Note: Released By: DREWIS | |||
| BLD | COMPLETE | 04/17/2018 | 04/18/2018 |
| Note: Released By: JHINDMAN | |||
| PLUM | COMPLETE | 04/17/2018 | 04/20/2018 |
| Note: Released By: FREODICA Revision: chnaged plumbing layout and riser due to relocation of bathroom. | |||
| MECH | COMPLETE | 04/17/2018 | 04/20/2018 |
| Note: Released By: FREODICA Revision: changed hvac due to relocation of bathroom | |||
| BLD | HOLD | 02/26/2018 | 02/28/2018 |
| Note: Held By: JHINDMAN 1. new restroom approach must have 12" minumum space on latch side for a push approach 6th ed. FBC A404.2. J. Hindman 986-3784. | |||
| MECH | HOLD | 02/26/2018 | 02/28/2018 |
| Note: Held By: FREODICA Revision: Provide revised hvac plan signed and sealed by design professional per FBC 6th ed. 107.1. F.Reodica -386-986-4734. | |||
| PLUM | HOLD | 02/26/2018 | 02/28/2018 |
| Note: Held By: FREODICA Revision: 1. Sanitary layout does not match with sanitary risser diagarm. Coordinate per FBC 6th ed. 107.2.1. 2. Identify all fixxture on sanitary layout and sanitary riser for clarity per FBC 6th ed. 107.2.1. 3. Provide venting system of plumbing fixtures to comply with FBCP 6th ed. 901.1. 4. Provide separate domestic water (hot and cold ) layout and riser per FBC 6th ed.107.3.5. F.Reodica -386-986-4734. | |||
| PLUM | HOLD | 02/16/2018 | 08/02/2017 |
| Note: Repeat comments for items 2 and 3: 2. Due to increase of occupant load, the minimum required plumbing fixtures shall comply with FBCP 5th ed. 403. 3. Provide sanitary and domestic water (hot and cold) riser diagrams based on the increased occupant load as mentioned above (item2) either prepared by design professional or plumbing contractor per FBC 5th ed. 107.3.5. F.Reodica -386-986-4734. Notes: Comments based on correction submittal dated 5-7-17: Item 2 : Calculation for fixture requireremenrs shown on dwg A-3 shall be corrected. Additional (1) drinking fountain is required. Item 3 : Saitary riser diagram shall include (2) drinking fountains. Provide domestic water (hot and cold ) riser diagram. | |||
| BLD | COMPLETE | 12/11/2017 | 12/15/2017 |
| ELEC | COMPLETE | 12/04/2017 | 12/06/2017 |
| PLUM | COMPLETE | 12/04/2017 | 12/06/2017 |
| Note: Released By: RLEE | |||
| MECH | COMPLETE | 12/04/2017 | 12/06/2017 |
| Note: Released By: RLEE | |||
| BLD | HOLD | 12/04/2017 | 12/06/2017 |
| Note: Held By: RLEE 5th Review, Still not met. 2. Provide door maneuvering clearances that meet the 5th ed. FBC Accessibility 404 for all doors including the restrooms. The door maneuvering clearances is mandatory Federal ADA code for all doors. The bathroom doors still does not meet the Federal ADA and Florida ADA requirements for door maneuvering clearances at door edge Please refer tro the FBC Accessiibility for clarification., | |||
| PLUM | HOLD | 10/26/2017 | 11/01/2017 |
| Note: 1. The new additional restrooms do not comply with the minimum number of required plumbing facilities for the total occupant load and occupancy classification per FBCP 5th ed. 403. 2. The door swing at the new unisex rest room shall not swing into the clear floor space or clearance required for any fixtures per FBC Accessibilty 5th ed. 603.2.3. 3. Revise the sanitary riser diagram to match with above comment 1 per FBC 5th ed. 107.2.1. F.Reodica -386-986-4734. | |||
| MECH | HOLD | 10/26/2017 | 11/01/2017 |
| Note: Provide proposed hvac plan including outdoor air calculation signed and sealed by engineer or by an hvac contractor with signature and license number per FBC 5th ed. 105.3.1.2 as previously requested. F.Reodica -386-986-4734. | |||
| ELEC | HOLD | 10/26/2017 | 10/30/2017 |
| Note: Held By: DREWIS Please provide a floor plan showing the electrical work to be done. D. Rewis 986-4736 | |||
| BLD | HOLD | 10/26/2017 | 11/07/2017 |
| Note: 1. Provide complete dimensions for all restrooms including clear floor spaces. 2. Provide door maneuvering clearances that meet the 5th ed. FBC Accessibility 404 for all doors including the restrooms. 3. Provide a clear width of 36" in the new womens restroom in the walkway between the stall and the mens restroom wall 5th ed. FBC 1018.1. J. Hindman 986-3784. | |||
| ELEC | HOLD | 07/26/2017 | 08/01/2017 |
| Note: 1. Provide a complete electrical plan with panel schedules 5th ed. FBC 107.3.5. J. Hindman 986-3784. 3rd request. The provided panel schedules do not show the proposed circuits for the project. | |||
| BLD | HOLD | 07/26/2017 | 08/01/2017 |
| Note: 1. Demonstrate what the smoke partition is constructed of, how it is constructed, and how is the continuity of the smoke partition obtained. This is done by a detail demonstrating the separation of the corridor, and complying with the 5th edition Florida Building Code 710.4 J. Hindman 986-3784. | |||
| MECH | HOLD | 07/26/2017 | 08/02/2017 |
| Note: Repeat comment: Coorection submittal: Existing hvac plan was submitted with a note referring to a mechanical contractor's responsibilty for the porposed design and installation of hvac system and energy calculations. Calculation of outdoor air requirement shall be included per FBCM 5th ed. 403. F.Reodica -386-986-4734. New comments based on submital dated 7-28-17: Please note that only existing hvac plan was submitted. Proposed hvac plan is required including the distributed CFM's, duct sizes, capacities of hvac units, outdoor air reqiremets and heating/cooling load calculations as previously requested. | |||
| PLUM | HOLD | 07/26/2017 | 08/02/2017 |
| Note: Repeat comments for items 2 and 3: 2. Due to increase of occupant load, the minimum required plumbing fixtures shall comply with FBCP 5th ed. 403. 3. Provide sanitary and domestic water (hot and cold) riser diagrams based on the increased occupant load as mentioned above (item2) either prepared by design professional or plumbing contractor per FBC 5th ed. 107.3.5. F.Reodica -386-986-4734. Notes: Comments based on correction submittal dated 5-7-17: Item 2 : Calculation for fixture requireremenrs shown on dwg A-3 shall be corrected. Additional (1) drinking fountain is required. Item 3 : Saitary riser diagram shall include (2) drinking fountains. Provide domestic water (hot and cold ) riser diagram. | |||
| BLD | HOLD | 05/07/2017 | 05/08/2017 |
| Note: 1. The rated corridor cannot end at the rear hall by the restroom.1018.6 Corridor continuity. Fire-resistance-rated corridors shall be continuous from the point of entry to an exit, and shall not be interrupted by intervening rooms. J. Hindman 986-3784. | |||
| ELEC | HOLD | 05/07/2017 | 05/08/2017 |
| Note: 1. Provide a complete electrical plan with panel schedules 5th ed. FBC 107.3.5. J. Hindman 986-3784. 2nd request. | |||
| FI1 | COMPLETE | 05/07/2017 | 05/08/2017 |
| PLUM | HOLD | 05/07/2017 | 05/09/2017 |
| Note: Repeat comments for items 2 and 3: 2. Due to increase of occupant load, the minimum required plumbing fixtures shall comply with FBCP 5th ed. 403. 3. Provide sanitary and domestic water (hot and cold) riser diagrams based on the increased occupant load as mentioned above (item2) either prepared by design professional or plumbing contractor per FBC 5th ed. 107.3.5. F.Reodica -386-986-4734. Notes: Comments based on correction submittal dated 5-7-17: Item 2 : Calculation for fixture requireremenrs shown on dwg A-3 shall be corrected. Additional (1) drinking fountain is required. Item 3 : Saitary riser diagram shall include (2) drinking fountains. Provide domestic water (hot and cold ) riser diagram. | |||
| MECH | HOLD | 05/07/2017 | 05/08/2017 |
| Note: Coorection submittal: Existing hvac plan was submitted with a note referring to a mechanical contractor's responsibilty for the porposed design and installation of hvac system and energy calculations. Calculation of outdoor air requirement shall be included per FBCM 5th ed. 403. F.Reodica -386-986-4734. | |||
| FI1 | HOLD | 04/03/2017 | 04/03/2017 |
| Note: 1. Provide 1 hour rated corridors per 5th ed. Florida Fire Prevention code 101 16.3.6. J. Hindman 986-3784. | |||
| MECH | HOLD | 04/03/2017 | 04/03/2017 |
| Note: 1. Provide exisiting and proposed hvac plan suitable for review, construction and inspection per FBC 5th ed. 107.2.1. 2. Proide heating and cooling load calculations due due change in occupancy classification and increase of occupant load per FBC existing building 5th ed. 809/FBCE 5th ed. C403.2.1. 3. Provide hvac contractor per FS 489. | |||
| PLUM | HOLD | 03/30/2017 | 04/03/2017 |
| Note: 1. Provide existing and proposed plumbing plans suitable for review, construction and inspection per FBC 5th ed. 107.2.1 2. Due to increase of occupant load, the minimum required plumbing fixtures shall comply with FBCP 5th ed. 403. 3. Provide sanitary and domestic water (hot and cold) riser diagrams based on the increased occupant load as mentioned above (item2) either prepared by design professional or plumbing contractor per FBC 5th ed. 107.3.5. 4. Provide material specifications of DWV and domestic water (hot and cold) per FBCP 5th ed.605/702. F.Reodica -386-986-4734. | |||
| UD1 | COMPLETE | 03/30/2017 | 04/03/2017 |
| ZON | COMPLETE | 03/30/2017 | 03/30/2017 |
| BLD | HOLD | 03/30/2017 | 04/03/2017 |
| Note: 1. Identify if side A and side B are to be two separate businesses. 2. Provide the correct occupancy I-4. (the group D occupancy no longer is in the current code. 5th ed. FBC 308.6. 3. Provide correct occupant loads for the business rooms 1/100. 5th ed. FBC 1004.1. 4. Provide an existing and new floorplans. 5th ed. FBC 107.2.1. J. Hindman 986-3784. | |||
| ELEC | HOLD | 03/30/2017 | 04/03/2017 |
| Note: 1. Provide a complete electrical plan with panel schedules and load calculations 5th ed. FBC 107.3.5. J. Hindman 986-3784. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 01/11/2019 |
| REINSPECTION FEE | ¤40.00 | 01/11/2019 |
| REVISION | ¤40.00 | 01/11/2019 |
| REVISION | ¤40.00 | 04/20/2018 |
| REVISION | ¤40.00 | 04/20/2018 |
| SITE PLAN 20 | ¤20.00 | 12/18/2017 |
| SURCHARGE FS 533.721 | ¤4.81 | 12/18/2017 |
| SURCHARGE - FS 468.631 | ¤4.81 | 12/18/2017 |
| ADMIN COMMERCIAL | ¤60.00 | 12/18/2017 |
| INSPECTION - COMMERCIAL ADD | ¤119.00 | 12/18/2017 |
| CONTRACTOR CHANGE | ¤40.00 | 12/18/2017 |
| CONTRACTOR CHANGE | ¤40.00 | 12/18/2017 |
| CONTRACTOR CHANGE | ¤40.00 | 12/18/2017 |
| ELECTRIC FEE | ¤70.20 | 12/18/2017 |
| PLAN CHECK FEE | ¤100.00 | 12/18/2017 |
| PLUMBING FEE | ¤70.20 | 12/18/2017 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤769.02 |