I want to search for...
Permit #2017031305
Permit Details
Status: COED
| Parcel Id: 07-11-31-7012-00060-0290 |
| CONDITIONED SPACE: 1762 sqft |
| GARAGE: 499 sqft |
| OPENED PORCH (WITH ROOF) : 50 sqft |
| OPENED PORCH (WITH ROOF) : 193 sqft |
| Total Square Footage: 2504 sqft |
| Block: 00060 |
| Subdivision: 2187 - SECTION 12-BELLE TERRE |
| Job Phone: (386) 445-2222 |
| Location Address: 57 BANNBURY LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/20/2017 |
| NOC: RECORDED |
| Applicant name: MICHAEL STEPHAN MULLEN |
| Owner: DUNCAN, ELIZABETH |
|
Address 55 ONEIDA STREET ST AUGUSTINE, FL 32084 |
| Lot: 0290 |
| Contracted Stated Job Value: ¤164,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
TOWN & COUNTRY HOMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1 Enterprise Drive Bunnell, FL 32110 |
CGC049972 (Exp: 08/31/2026) | (386) 445-2222 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
DENNIS GENE GAINEY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P.O. BOX 1203 Bunnell, FL 32110 |
CFC046004 (Exp: 08/31/2026) | (386) 437-5637 | 386-437-3012 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 08/25/2017 | FINAL APPROVED | CMINI |
| ROW - FINAL INSPECTION | 08/24/2017 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION. ROAD ASPHALT REPAIR TO BE DONE BY THE CITY. ALREADY ENTERED BY ROBERT | |||
| U -UTILITY RESIDENTIAL FINAL | 08/23/2017 | FINAL APPROVED | JNICHOLS |
| ROW - FINAL INSPECTION | 08/23/2017 | Disapproved - NO FEE | RGROSS |
| Note: ROAD AT THE END OF THE DRIVEWAY NEEDS REMOVED AND REPLACE WITH HOT PATCH. SEED AND STRAW NEEDED ALONG THE RIGHT SIDE PROPERTY LINE. ADDED NOTES: BUILDER WOULD LIKE CITY TO DO THE ROAD REPAIR. | |||
| ROW - FINAL APRON (AFTER POUR) | 08/23/2017 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION. APPROVED | |||
| FINAL SURVEY (OFFICE USE ONLY) | 08/22/2017 | APPROVED | JHINDMAN |
| ELECTRIC - EARLY POWER | 08/11/2017 | APPROVED - AS NOTED | RMARTIN |
| Note: per contractor SPOKE TO DELL FPL RELEASED EARLY POWER 3:30 | |||
| ELECTRIC - EARLY POWER | 08/09/2017 | CANCELLED BY APPLICANT | AIRS WEB |
| Note: per contractor | |||
| ROW - FINAL APRON (AFTER POUR) | 08/09/2017 | Disapproved -FEE REQUIRED | CTROHA |
| Note: MUST HAVE SOD IN PLACE AND FINAL SURVEY ON SITE. NOT READY FOR THIS INSPECTION | |||
| ROW- PRE-APRON (PRE-POUR) | 08/02/2017 | APPROVED | CTROHA |
| Note: READY TO POUR It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete. | |||
| INSULATION | 07/06/2017 | APPROVED | JCOLASANTI |
| LATH/BRICK/ WATER BARRIER | 07/05/2017 | APPROVED | JCOLASANTI |
| ALL ROUGH | 07/05/2017 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 06/30/2017 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: THIS IS A REINSPECTION provide 10 test pressure on waste lines. 5th ed. FBC R P2503.5.1. 2 ...... eed to bond metal boxes guest bat and front porch...need greed ground screw at panel . | |||
| ALL ROUGH | 06/28/2017 | Disapproved - NO FEE | JCOLASANTI |
| Note: roof shingles must be completed before all rough inspection | |||
| ALL ROUGH | 06/27/2017 | CANCELLED BY APPLICANT | AIRS WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/20/2017 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| ROOF VALLEY & METAL | 06/20/2017 | APPROVED | JCOLASANTI |
| EXTERIOR STRAP/CLIP | 06/19/2017 | APPROVED | JCOLASANTI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/19/2017 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: need two straps at girder truss garage (marked on plans) need h2.5 at rafter second location and at ridge/rafter connection per plan detail. garage location and rear of house | |||
| WINDOW NAILING | 06/19/2017 | APPROVED | JCOLASANTI |
| WALL SHEATHING | 06/12/2017 | APPROVED | JCOLASANTI |
| ROOF SHEATHING | 06/12/2017 | APPROVED | JCOLASANTI |
| FOUND SURVEY APPROVED (OFFICE) | 05/31/2017 | APPROVED | FREODICA |
| MONOLITHIC SLAB | 05/18/2017 | APPROVED - AS NOTED | JCOLASANTI |
| Note: need compaction test sticker in bov by next inspection | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 05/16/2017 | APPROVED | JGIBSON |
| GRAVITY SEWER TEST | 05/16/2017 | APPROVED | JGIBSON |
| U - SEWER TIE IN | 05/16/2017 | APPROVED | JNICHOLS |
| ELECTRIC TEMP POLE | 05/08/2017 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO SUSAN FPL RELEASED TEMP POLE 11:40 |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 08/18/2017 | 08/22/2017 |
| Note: Released By: JHINDMAN FINAL S | |||
| SW1 | COMPLETE | 05/30/2017 | 05/31/2017 |
| Note: Released By: FREODICA foundation s | |||
| BLD | COMPLETE | 05/23/2017 | 06/01/2017 |
| BLD | COMPLETE | 04/20/2017 | 04/20/2017 |
| PLUM | COMPLETE | 04/17/2017 | 04/18/2017 |
| MECH | COMPLETE | 04/17/2017 | 04/18/2017 |
| BLD | HOLD | 04/17/2017 | 04/18/2017 |
| Note: Repeat comment: Stucco application on wood frame construction shall comply with FBCR 5th ed. R703. F.Reodica - 386-986-4734. Note: For stucco over wood, 7/8 inch thickness is required and shall not be less than three(3) coats. See FBCR 5th ed. R703.6.2/Table R702.1(1) . | |||
| ZON | COMPLETE | 04/17/2017 | 04/17/2017 |
| ZON | HOLD | 04/11/2017 | 04/11/2017 |
| Note: Repeat Comments: 1)Banding must wrap corners on each side at least two feet. 2) House does not meet interior side setback of 7.5' T Williams 986.2655 | |||
| PLUM | HOLD | 04/11/2017 | 04/11/2017 |
| Note: Repeat comment: Sanitary risesr diagram does not match with floor plan. Coordinate per FBC 5th ed. 107.2.1. F.Reodica - 386-986-4734. Note: Laundry tub is missing on sanitary riser diagram. | |||
| MECH | HOLD | 04/11/2017 | 04/11/2017 |
| Note: Provide complete energy calculations to include manufacturer, model number of outdoor and indoor units, sensible and total cooling capacities at the design conditions per FBCEC 5th ed. R403.6.1. F.Reodica-386-986-4734. | |||
| BLD | HOLD | 04/11/2017 | 04/11/2017 |
| Note: Repeat comment: Stucco application on wood frame construction shall comply with FBCR 5th ed. R703. F.Reodica - 386-986-4734. Note: Stucco finish shall not be less than three (3) coats, 7/8" thick when applied over metal lath or wire lath for wood frame. See FBCR Table R703.6.2/Table R702.1(1). | |||
| BLD | HOLD | 03/31/2017 | 03/31/2017 |
| Note: Stucco application on wood frame construction shall comply with FBCR 5th ed. R703. F.Reodica - 386-986-4734. | |||
| ELEC | COMPLETE | 03/31/2017 | 04/03/2017 |
| ENGIN1 | COMPLETE | 03/31/2017 | 04/07/2017 |
| MECH | HOLD | 03/31/2017 | 03/31/2017 |
| Note: Conditioned space area on energy calculations does not match with floor plan. Coordinate per FBC 5th ed. 107.2.1. F.Reodica -386-986-4734. | |||
| PLUM | HOLD | 03/31/2017 | 03/31/2017 |
| Note: Sanitary risesr diagram does not match with floor plan. Coordinate per FBC 5th ed. 107.2.1. F.Reodica - 386-986-4734. | |||
| SW1 | COMPLETE | 03/31/2017 | 04/03/2017 |
| UD1 | COMPLETE | 03/31/2017 | 04/03/2017 |
| ZON | HOLD | 03/31/2017 | 03/31/2017 |
| Note: Banding must wrap corners on each side at least two feet Shrubs around AC pad must be 7 gallon Five trees required, one shade tree and four understory - Pine trees do not count for residential lots House does not meet intereior side setback of 7.5' |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| MISCELLANEOUS | ¤292.00 | 08/23/2017 |
| REINSPECTION FEE | ¤40.00 | 08/22/2017 |
| REINSPECTION FEE | ¤40.00 | 07/06/2017 |
| REINSPECTION FEE | ¤40.00 | 07/06/2017 |
| REVISION | ¤40.00 | 06/06/2017 |
| SITE PLAN 20 | ¤20.00 | 04/20/2017 |
| SURCHARGE FS 533.721 | ¤17.54 | 04/20/2017 |
| SURCHARGE - FS 468.631 | ¤17.54 | 04/20/2017 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/20/2017 |
| 3% TRANS IMPACT FEE CREDIT | (¤93.74) | 04/20/2017 |
| NEW RESIDENTIAL INSPECTIONS | ¤452.00 | 04/20/2017 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 04/20/2017 |
| PLAN CHECK FEE | ¤90.40 | 04/20/2017 |
| PLUMBING FEE | ¤195.60 | 04/20/2017 |
| ADMIN FEE | ¤20.00 | 04/20/2017 |
| ELECTRIC FEE | ¤195.60 | 04/20/2017 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.43) | 04/20/2017 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤214.29 | 04/20/2017 |
| IMPACT FEE PARKS | ¤849.24 | 04/20/2017 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 04/20/2017 |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | 04/20/2017 |
| MECHANICAL FEE | ¤195.60 | 04/20/2017 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,398.83 |