Permit #2017031305

Permit Details

Status: COED

Parcel Id: 07-11-31-7012-00060-0290
CONDITIONED SPACE: 1762 sqft
GARAGE: 499 sqft
OPENED PORCH (WITH ROOF) : 50 sqft
OPENED PORCH (WITH ROOF) : 193 sqft
Total Square Footage: 2504 sqft
Block: 00060
Subdivision: 2187 - SECTION 12-BELLE TERRE
Job Phone: (386) 445-2222
Location Address: 57 BANNBURY LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/20/2017
NOC: RECORDED
Applicant name: MICHAEL STEPHAN MULLEN
Owner: DUNCAN, ELIZABETH

Address

55 ONEIDA STREET

ST AUGUSTINE, FL 32084

Lot: 0290
Contracted Stated Job Value: ¤164,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

TOWN & COUNTRY HOMES
Status Location Address State License Number Phone
ACTIVE

1 Enterprise Drive

Bunnell, FL 32110

CGC049972 (Exp: 08/31/2026) (386) 445-2222

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
DENNIS GENE GAINEY
Status Location Address State License Number Phone Fax
INACTIVE

P.O. BOX 1203

Bunnell, FL 32110

CFC046004 (Exp: 08/31/2026) (386) 437-5637 386-437-3012
BARRY D MARTIN
Status Location Address State License Number Phone Fax
CANCEL

1650 N STATE STREET

Bunnell, FL 32110

CCC033728 (Exp: 08/31/2020) (386) 437-7700 (386)437-7701

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/25/2017 FINAL APPROVED CMINI
ROW - FINAL INSPECTION 08/24/2017 APPROVED RGROSS
Note: THIS IS A REINSPECTION. ROAD ASPHALT REPAIR TO BE DONE BY THE CITY. ALREADY ENTERED BY ROBERT
U -UTILITY RESIDENTIAL FINAL 08/23/2017 FINAL APPROVED JNICHOLS
ROW - FINAL INSPECTION 08/23/2017 Disapproved - NO FEE RGROSS
Note: ROAD AT THE END OF THE DRIVEWAY NEEDS REMOVED AND REPLACE WITH HOT PATCH. SEED AND STRAW NEEDED ALONG THE RIGHT SIDE PROPERTY LINE. ADDED NOTES: BUILDER WOULD LIKE CITY TO DO THE ROAD REPAIR.
ROW - FINAL APRON (AFTER POUR) 08/23/2017 APPROVED RGROSS
Note: THIS IS A REINSPECTION. APPROVED
FINAL SURVEY (OFFICE USE ONLY) 08/22/2017 APPROVED JHINDMAN
ELECTRIC - EARLY POWER 08/11/2017 APPROVED - AS NOTED RMARTIN
Note: per contractor SPOKE TO DELL FPL RELEASED EARLY POWER 3:30
ELECTRIC - EARLY POWER 08/09/2017 CANCELLED BY APPLICANT AIRS WEB
Note: per contractor
ROW - FINAL APRON (AFTER POUR) 08/09/2017 Disapproved -FEE REQUIRED CTROHA
Note: MUST HAVE SOD IN PLACE AND FINAL SURVEY ON SITE. NOT READY FOR THIS INSPECTION
ROW- PRE-APRON (PRE-POUR) 08/02/2017 APPROVED CTROHA
Note: READY TO POUR It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete.
INSULATION 07/06/2017 APPROVED JCOLASANTI
LATH/BRICK/ WATER BARRIER 07/05/2017 APPROVED JCOLASANTI
ALL ROUGH 07/05/2017 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
ALL ROUGH 06/30/2017 Disapproved -FEE REQUIRED JCOLASANTI
Note: THIS IS A REINSPECTION provide 10 test pressure on waste lines. 5th ed. FBC R P2503.5.1. 2 ...... eed to bond metal boxes guest bat and front porch...need greed ground screw at panel .
ALL ROUGH 06/28/2017 Disapproved - NO FEE JCOLASANTI
Note: roof shingles must be completed before all rough inspection
ALL ROUGH 06/27/2017 CANCELLED BY APPLICANT AIRS WEB
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/20/2017 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
ROOF VALLEY & METAL 06/20/2017 APPROVED JCOLASANTI
EXTERIOR STRAP/CLIP 06/19/2017 APPROVED JCOLASANTI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/19/2017 Disapproved -FEE REQUIRED JCOLASANTI
Note: need two straps at girder truss garage (marked on plans) need h2.5 at rafter second location and at ridge/rafter connection per plan detail. garage location and rear of house
WINDOW NAILING 06/19/2017 APPROVED JCOLASANTI
WALL SHEATHING 06/12/2017 APPROVED JCOLASANTI
ROOF SHEATHING 06/12/2017 APPROVED JCOLASANTI
FOUND SURVEY APPROVED (OFFICE) 05/31/2017 APPROVED FREODICA
MONOLITHIC SLAB 05/18/2017 APPROVED - AS NOTED JCOLASANTI
Note: need compaction test sticker in bov by next inspection
PLUMBING 1ST ROUGH UNDERGROUND 05/16/2017 APPROVED JGIBSON
GRAVITY SEWER TEST 05/16/2017 APPROVED JGIBSON
U - SEWER TIE IN 05/16/2017 APPROVED JNICHOLS
ELECTRIC TEMP POLE 05/08/2017 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED TEMP POLE 11:40

Review History

Department Status Date In Date Out
SW1 COMPLETE 08/18/2017 08/22/2017
Note: Released By: JHINDMAN FINAL S
SW1 COMPLETE 05/30/2017 05/31/2017
Note: Released By: FREODICA foundation s
BLD COMPLETE 05/23/2017 06/01/2017
BLD COMPLETE 04/20/2017 04/20/2017
PLUM COMPLETE 04/17/2017 04/18/2017
MECH COMPLETE 04/17/2017 04/18/2017
BLD HOLD 04/17/2017 04/18/2017
Note: Repeat comment: Stucco application on wood frame construction shall comply with FBCR 5th ed. R703. F.Reodica - 386-986-4734. Note: For stucco over wood, 7/8 inch thickness is required and shall not be less than three(3) coats. See FBCR 5th ed. R703.6.2/Table R702.1(1) .
ZON COMPLETE 04/17/2017 04/17/2017
ZON HOLD 04/11/2017 04/11/2017
Note: Repeat Comments: 1)Banding must wrap corners on each side at least two feet. 2) House does not meet interior side setback of 7.5' T Williams 986.2655
PLUM HOLD 04/11/2017 04/11/2017
Note: Repeat comment: Sanitary risesr diagram does not match with floor plan. Coordinate per FBC 5th ed. 107.2.1. F.Reodica - 386-986-4734. Note: Laundry tub is missing on sanitary riser diagram.
MECH HOLD 04/11/2017 04/11/2017
Note: Provide complete energy calculations to include manufacturer, model number of outdoor and indoor units, sensible and total cooling capacities at the design conditions per FBCEC 5th ed. R403.6.1. F.Reodica-386-986-4734.
BLD HOLD 04/11/2017 04/11/2017
Note: Repeat comment: Stucco application on wood frame construction shall comply with FBCR 5th ed. R703. F.Reodica - 386-986-4734. Note: Stucco finish shall not be less than three (3) coats, 7/8" thick when applied over metal lath or wire lath for wood frame. See FBCR Table R703.6.2/Table R702.1(1).
BLD HOLD 03/31/2017 03/31/2017
Note: Stucco application on wood frame construction shall comply with FBCR 5th ed. R703. F.Reodica - 386-986-4734.
ELEC COMPLETE 03/31/2017 04/03/2017
ENGIN1 COMPLETE 03/31/2017 04/07/2017
MECH HOLD 03/31/2017 03/31/2017
Note: Conditioned space area on energy calculations does not match with floor plan. Coordinate per FBC 5th ed. 107.2.1. F.Reodica -386-986-4734.
PLUM HOLD 03/31/2017 03/31/2017
Note: Sanitary risesr diagram does not match with floor plan. Coordinate per FBC 5th ed. 107.2.1. F.Reodica - 386-986-4734.
SW1 COMPLETE 03/31/2017 04/03/2017
UD1 COMPLETE 03/31/2017 04/03/2017
ZON HOLD 03/31/2017 03/31/2017
Note: Banding must wrap corners on each side at least two feet Shrubs around AC pad must be 7 gallon Five trees required, one shade tree and four understory - Pine trees do not count for residential lots House does not meet intereior side setback of 7.5'

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
MISCELLANEOUS ¤292.00 08/23/2017
REINSPECTION FEE ¤40.00 08/22/2017
REINSPECTION FEE ¤40.00 07/06/2017
REINSPECTION FEE ¤40.00 07/06/2017
REVISION ¤40.00 06/06/2017
SITE PLAN 20 ¤20.00 04/20/2017
SURCHARGE FS 533.721 ¤17.54 04/20/2017
SURCHARGE - FS 468.631 ¤17.54 04/20/2017
STORM WATER PERMIT FEES ¤80.00 04/20/2017
3% TRANS IMPACT FEE CREDIT (¤93.74) 04/20/2017
NEW RESIDENTIAL INSPECTIONS ¤452.00 04/20/2017
3% PARKS IMPACT FEE CREDIT (¤25.48) 04/20/2017
PLAN CHECK FEE ¤90.40 04/20/2017
PLUMBING FEE ¤195.60 04/20/2017
ADMIN FEE ¤20.00 04/20/2017
ELECTRIC FEE ¤195.60 04/20/2017
3% FIRE IMPACT FEE CREDIT (¤6.43) 04/20/2017
IMPACT FEE FIRE NONRESIDENTIAL ¤214.29 04/20/2017
IMPACT FEE PARKS ¤849.24 04/20/2017
IMPACT FEE SCHOOL ¤3,600.00 04/20/2017
IMPACT FEE TRANSPORTATION ¤3,124.67 04/20/2017
MECHANICAL FEE ¤195.60 04/20/2017
Fees Total Due: ¤0.00 Total Paid: ¤9,398.83