Permit #2017050332

Permit Details

Status: COED

Parcel Id: 33-11-31-3061-00020-0090
CONDITIONED SPACE: 3395 sqft
GARAGE: 1064 sqft
OPENED PORCH (WITH ROOF) : 307 sqft
OPENED PORCH (WITH ROOF) : 115 sqft
Total Square Footage: 4881 sqft
Block: 00020
Subdivision: 2108 - Hidden Lakes- Phase II-Toscana
Job Phone: 863-420-2100
Location Address: 26 NEW WATER OAK DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/08/2017
NOC: RECORDED
Applicant name: YUVAL BOTANSKY
Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC

Address

131 CHADWICK DRIVE

DAVENPORT, FL 33837

Lot: 0090
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

APPLIED BUILDING DEVELOPMENT COMPANY - OAKHILLS IN
Status Location Address State License Number Phone Fax
ACTIVE

131 CHADWICK DRIVE

DAVENPORT, FL 33837

CRC1330762 (Exp: 08/31/2026) 863-420-2100 386-517-6865

Sub Contractors

TERRY HILE BURD
Status Location Address State License Number Phone Fax
INACTIVE

PO Box 180308

CASSELBERRY, FL 32707

CAC1814423 (Exp: 08/31/2024) (407) 831-3600 (407)831-2893
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JOSEPH H STRADA JR
Status Location Address State License Number Phone
CANCEL

3400 ST JOHNS PKWY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2022) 877-906-1113

Inspection History

Type Request Date Result Inspector
ROW - FINAL INSPECTION 06/04/2018 FINAL APPROVED KHOWELL
ROW - FINAL APRON (AFTER POUR) 05/31/2018 APPROVED - AS NOTED KHOWELL
Note: FINAL SURVEY HAS TO BE ON SITE FOR FINAL R.O.W. INSPECTION NOT IN DOC BOX
BLD - BUILDING FINAL 05/31/2018 FINAL APPROVED CMINI
ROW - FINAL INSPECTION 05/31/2018 Disapproved -FEE REQUIRED KHOWELL
Note: FINAL SURVEY HAS TO BE ON SITE FOR FINAL R.O.W. INSPECTION NOT IN DOC BOX, CLEAN UP DEBRIS FROM SITE AND VACANT LOT, SEED AND STRAW DISTURBED AREA AT REAR OF PROPERTY AND SOD THE POND BANKS. POND BANK WAS DISTURBED WILL NEED TO BE SURVEYED AFTER SOD TO VERIFY THAT IT WAS NOT CHANGED
FINAL SURVEY (OFFICE USE ONLY) 05/30/2018 APPROVED DREWIS
U -UTILITY RESIDENTIAL FINAL 05/29/2018 FINAL APPROVED LFITZGERALD
U-CROSS CONNECTION 05/29/2018 APPROVED LFITZGERALD
ROW- PRE-APRON (PRE-POUR) 05/16/2018 APPROVED - AS NOTED CTROHA
Note: READY FOR PAVERS It is the BUILDER'S RESPONSIBILITY: to obtain required compaction of base material and to form the driveway to the approved site plan. PRIOR to placement of pavers.
ROW- PRE-APRON (PRE-POUR) 05/07/2018 PARTIALLY APPROVED KHOWELL
Note: SIDEWALK AND APRON ONLY PAVER UPPER DRIVEWAY
ELECTRIC - EARLY POWER 05/03/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED EARLY POWER 3:30
GRAVITY SEWER TEST 05/01/2018 APPROVED JGIBSON
U - SEWER TIE IN 05/01/2018 APPROVED LFITZGERALD
TUB SET 04/20/2018 APPROVED JGIBSON
LATH/BRICK/ WATER BARRIER 03/19/2018 APPROVED CMINI
INSULATION 03/09/2018 APPROVED CMINI
ALL ROUGH 03/06/2018 APPROVED - AS NOTED CMINI
Note: all corrected, when tub and motor set need tub set inspection
ELECTRIC-TUG 03/06/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED TUG POWER 3:15
ELECTRIC-TUG 03/05/2018 CANCELLED BY APPLICANT CMINI
ALL ROUGH 03/05/2018 CANCELLED BY APPLICANT CMINI
ALL ROUGH 03/01/2018 Disapproved -FEE REQUIRED CMINI
Note: need to strap wire in attic at front entrance every 4-1/2' NEC 334.30 . need tub set inspection when installed and spa motor installed. fire blocking needed at chase walls and drop ceiling and also check laundry room at drop trusses. need to phase out conductors that are used as hot that is not identified by color NEC 210.5(c). can not locate off ridge vents.
ELECTRIC-TUG 02/28/2018 Disapproved -FEE REQUIRED RMARTIN
Note: UN-USED OPENINGS IN METER DISCONNECT NEED TO CLOSE UP NEC 110.12A
ROOF VALLEY & METAL 02/28/2018 APPROVED CMINI
ROOF SHEATHING/BRACE/TIES/DOWN CELL-GREEN 02/22/2018 APPROVED - AS NOTED CMINI
Note: removed furring strips to bump roof, checked straps, all ok
ELECTRIC-TUG 02/16/2018 Disapproved -FEE REQUIRED RMARTIN
Note: UN-USED OPENINGS IN METER DISCONNECT NEED TO CLOSE UP NEC 110.12A
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/30/2018 CANCELLED BY APPLICANT CMINI
Note: THIS IS A REINSPECTION
ELECTRIC-TUG 01/03/2018 Disapproved - NO FEE RMARTIN
Note: APPROVED RISER DIAGRAM DOES NOT MATCH SERVICE THAT IS INSTALLED, ALSO NEED TO HAVE UNDERGROUND CONDUIT INSTALLED
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/14/2017 Disapproved -FEE REQUIRED CMINI
Note: need to remove battens from roof and soffits for proper inspection. can not conduct full inspetion.
TIE BEAM / LINTEL 10/18/2017 APPROVED CMINI
FOUND SURVEY APPROVED (OFFICE) 10/12/2017 APPROVED JHINDMAN
MONOLITHIC SLAB 09/01/2017 APPROVED DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 08/21/2017 APPROVED JGIBSON
ELECTRIC TEMP POLE 08/03/2017 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED TEMP POWER 1:30
FOOTER 07/12/2017 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/12/2017 CANCELLED BY APPLICANT AIRS WEB
FOOTER 07/11/2017 CANCELLED BY APPLICANT CMINI

Review History

Department Status Date In Date Out
SW1 COMPLETE 05/30/2018 05/30/2018
Note: Released By: DREWIS rev final s
SW1 HOLD 05/25/2018 05/29/2018
Note: Held By: DREWIS FINAL S Elevations for back property line at the pool of 22.27', 22.25', 23.20' and 22.22' down to 22.21' allow flow onto adjacent property, Tech. Manual Sec. 5 Eng. Standard 300.01 A1 c6. Daniel Rewis 986-4736
BLD HOLD 02/08/2018 02/12/2018
Note: Held By: JHINDMAN 1. Uncover roof as per inspectors note from 12-14-17.. (need to remove battens from roof and soffits for proper inspection. can not conduct full inspetion. C. Mini). J. Hindman 986-3784.
ELEC COMPLETE 02/02/2018 02/07/2018
Note: Released By: DREWIS
BLD COMPLETE 01/25/2018 01/29/2018
Note: Released By: JHINDMAN
ELEC HOLD 01/25/2018 01/29/2018
Note: Held By: DREWIS Signature and license number of electrcal contractor needed, FBC 107.1 Daniel Rewis 986-4736
PLUM HOLD 01/16/2018 01/22/2018
Note: Held By: FREODICA Repeat comment: 1. The plans have the wrong address on them and are not for this permit. F.Rerodica-386-986-4734.
PLUM HOLD 11/30/2017 12/05/2017
Note: Held By: JHINDMAN 1. The plans have the wrong address on them and are not for this permit.
SW1 COMPLETE 10/10/2017 10/12/2017
Note: Released By: JHINDMAN FOUNDATION S
PLUM COMPLETE 08/09/2017 08/18/2017
Note: Released By: FREODICA Revision: Changed sanitary riser diagram and plumbing contractor.
ELEC COMPLETE 06/06/2017 06/07/2017
ELEC HOLD 05/23/2017 06/01/2017
Note: 1. Provide a full sizes electric plan signed and sealed by the Engineer or signed by the electrical contractor with their license number. J. Hindman 986-3784. 5th ed. FBC 107.1.
ZON COMPLETE 05/23/2017 05/24/2017
URB COMPLETE 05/23/2017 05/23/2017
URB HOLD 05/09/2017 05/09/2017
Note: Need 2 street trees live oak right front and drake elm left front. planted min 5ft from utilities and driveway maximum 12ft 6in from the ROW per the approved street tree plan.
BLD COMPLETE 05/08/2017 05/09/2017
ELEC HOLD 05/08/2017 05/09/2017
Note: 1. Provide electrical receptacle spacing in the kitchen that complies with 2011 NEC 210.52. J. Hindman 986-3784.
ENGIN1 COMPLETE 05/08/2017 05/08/2017
Note: New Water Oak Drive is designed with curb and gutter; therefore, a Swale Plan is not required.
MECH COMPLETE 05/08/2017 05/09/2017
PLUM COMPLETE 05/08/2017 05/09/2017
SW1 COMPLETE 05/08/2017 05/09/2017
UD1 COMPLETE 05/08/2017 05/09/2017
Note: This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON HOLD 05/08/2017 05/09/2017
Note: LANDSCACPE: Please add more trees for this size lot a minimum of 7 trees are required including 2 shade trees T. Williams 986.2655

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 05/31/2018
REINSPECTION FEE ¤40.00 03/01/2018
REINSPECTION FEE ¤40.00 03/01/2018
REINSPECTION FEE ¤40.00 03/01/2018
REINSPECTION FEE ¤40.00 03/01/2018
REVISION ¤40.00 03/01/2018
REVISION ¤40.00 03/01/2018
ADDITIONAL FEE ¤40.00 03/01/2018
ADMIN FEE ¤20.00 06/08/2017
ELECTRIC FEE ¤322.20 06/08/2017
3% FIRE IMPACT FEE CREDIT (¤6.43) 06/08/2017
IMPACT FEE FIRE NONRESIDENTIAL ¤214.29 06/08/2017
IMPACT FEE PARKS ¤849.24 06/08/2017
IMPACT FEE SCHOOL ¤3,600.00 06/08/2017
IMPACT FEE TRANSPORTATION ¤3,124.67 06/08/2017
MECHANICAL FEE ¤322.20 06/08/2017
3% PARKS IMPACT FEE CREDIT (¤25.48) 06/08/2017
PLAN CHECK FEE ¤174.80 06/08/2017
PLUMBING FEE ¤322.20 06/08/2017
SITE PLAN 20 ¤20.00 06/08/2017
SURCHARGE FS 533.721 ¤30.83 06/08/2017
SURCHARGE - FS 468.631 ¤30.83 06/08/2017
STORM WATER PERMIT FEES ¤80.00 06/08/2017
3% TRANS IMPACT FEE CREDIT (¤93.74) 06/08/2017
NEW RESIDENTIAL INSPECTIONS ¤874.00 06/08/2017
Fees Total Due: ¤0.00 Total Paid: ¤10,179.61