I want to search for...

Permit #2017051070

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7027-00530-0070
Block: 00530
Subdivision: 2128 - SECTION 27-WYNNFIELD
Job Phone: 386-313-6922
Location Address: 21 WOODBORN LN
Type: BA - BUILDING ADDITION
Issue Date: 06/21/2017
NOC: RECORDED
Applicant name: FRANK JOSEPH WHALEN
Owner: GALLO, DONATO JR & TONG O

Address

21 WOODBORN LANE

PALM COAST, FL 32164

Lot: 0070
Contracted Stated Job Value: ¤62,385.00
Job Description: 20 X 20 FT ADDITION W/BATHROOM
Type: CN

Contractor

EAST COAST BUILDING CORP
Status Location Address State License Number Phone Fax
ACTIVE

321 BRIARWOOD DRIVE

BUNNELL, FL 32110

CGC057860 (Exp: 08/31/2026) 386-313-6922 386-313-6922

Sub Contractors

JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144
THEODORE BARRON JOHNSON
Status Location Address State License Number Phone
ACTIVE

PO BOX 479

Flagler Beach, FL 32136

CAC057081 (Exp: 08/31/2026) 386-333-1672
JONATHAN P DUCEY
Status Location Address State License Number Phone
ACTIVE

505 WEST COURT STREET

BUNNELL, FL 32110

CFC1427093 (Exp: 08/31/2026) 386-503-6092

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 11/20/2017 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 11/17/2017 Disapproved - NO FEE JCOLASANTI
Note: need final survey on site at time of inspection... EXHAUST DUCTS SHALL NOT TERMINATE FROM OPERABLE OR NON OPERERABLE OPENINGS INTO THE BUILDING.M1506.2....
U -UTILITY RESIDENTIAL FINAL 11/15/2017 FINAL APPROVED LFITZGERALD
FINAL SURVEY (OFFICE USE ONLY) 11/08/2017 APPROVED DREWIS
Note: THIS IS A REINSPECTION
FINAL SURVEY (OFFICE USE ONLY) 10/09/2017 Disapproved - NO FEE DREWIS
Note: From grade at foundation wall to within 10' of foundation wall shall have a 6" fall, FBC R401.3. D. Rewis 986-4736
LATH/BRICK/ WATER BARRIER 08/25/2017 APPROVED DROCKWELL
INSULATION 08/25/2017 APPROVED DROCKWELL
ALL ROUGH 08/21/2017 APPROVED DROCKWELL
PLUMBING 2ND ROUGH 08/02/2017 APPROVED - AS NOTED JGIBSON
Note: THIS WAS FOR GRAVITY SEWER AND SECOND ROUGH PLUMBING
U - SEWER TIE IN 08/02/2017 APPROVED LFITZGERALD
WALL SHEATHING 07/27/2017 APPROVED JCOLASANTI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/27/2017 APPROVED - AS NOTED JCOLASANTI
Note: tighten rod located front left corner
FOUND SURVEY APPROVED (OFFICE) 07/27/2017 APPROVED JHINDMAN
MONOLITHIC SLAB 07/13/2017 APPROVED JCOLASANTI
PLUMBING 1ST ROUGH UNDERGROUND 07/07/2017 APPROVED JGIBSON

Review History

Department Status Date In Date Out
SW1 COMPLETE 11/07/2017 11/08/2017
Note: Released By: DREWIS rev final s
SW1 HOLD 10/09/2017 10/09/2017
Note: Held By: DREWIS FINAL S From grade at foundation wall to within 10' of foundation wall shall have a 6" fall, FBC R401.3. D. Rewis 986-4736
BLD COMPLETE 08/18/2017 08/23/2017
Note: Released By: RLEE
SW1 COMPLETE 07/26/2017 07/27/2017
Note: Released By: JHINDMAN foundation s
MECH COMPLETE 06/20/2017 06/20/2017
BLD COMPLETE 06/20/2017 06/20/2017
BLD HOLD 06/19/2017 06/19/2017
Note: Repeat comment: Provide Florida product approval for roofing material to be used or complete information on Roofing worksheet per FS 553.842/FBC 5th ed. 107.2.1. You have not listed a product approval number for the shingles.
MECH HOLD 06/19/2017 06/19/2017
Note: 1. Provide balanced return air from study room per FBCR 5th ed. M1602.4. 2. Clarify if the existing hvac units would be replaced as AHRI certificate of product ratings with 2.5 tons capacity and 14 Seer was submitted per FBC 5th ed. 107.2.1. F.Reodica -386-986-4734.
PLUM COMPLETE 06/09/2017 06/12/2017
MECH HOLD 06/09/2017 06/12/2017
Note: Repeat comment item 2: 2. Provide hvac plan to coordinate with above comment either prepared by design professional or an hvac contractor with signature and license number per FBC 105.3.1.2.. F.Reodica - 386-986-4734. Additional comment on submitted energy calculation: Energy performance level (EPL) display card shall be signed by the builder per FBCEC 5th ed. R401.3.
BLD HOLD 06/09/2017 06/12/2017
Note: Provide Florida product approval for roofing material to be used or complete information on Roofing worksheet per FS 553.842/FBC 5th ed. 107.2.1. You have not listed a product approval number for the shingles. J. Hindman 986-3784.
BLD HOLD 05/26/2017 06/02/2017
Note: Provide Florida product approval for roofing material to be used or complete information on Roofing worksheet per FS 553.842/FBC 5th ed. 107.2.1. F.Reodica - 386-986-4734.
SW1 COMPLETE 05/26/2017 06/02/2017
ZON COMPLETE 05/26/2017 05/26/2017
ELEC COMPLETE 05/26/2017 06/02/2017
MECH HOLD 05/26/2017 06/02/2017
Note: 1. Provide heating/cooling load calculation and identifiy if the new additional space would be supplied by existing hvac units or a new separate unit per FBC 5th 107.2.1/FBCEC 5th ed. R403.6.1 2. Provide hvac plan to coordinate with above comment either prepared by design professional or an hvac contractor with signature and license number per FBC 105.3.1.2.. F.Reodica - 386-986-4734.
PLUM HOLD 05/26/2017 06/02/2017
Note: Provide sanitary riser diagram either prepared by dsign professional or plumbing contractor with signature and license number indicated on the diagram per FBC 5th ed. 107.2.1. F.Reodica-386-986-4734.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN FEE ¤20.00 06/21/2017
ELECTRIC FEE ¤97.80 06/21/2017
MECHANICAL FEE ¤97.80 06/21/2017
PLAN CHECK FEE ¤40.00 06/21/2017
PLUMBING FEE ¤97.80 06/21/2017
REMODEL/ADDITION/ACCES INSPECT ¤40.00 06/21/2017
SITE PLAN 20 ¤20.00 06/21/2017
SURCHARGE FS 533.721 ¤6.20 06/21/2017
SURCHARGE - FS 468.631 ¤6.20 06/21/2017
STORM WATER PERMIT FEES ¤80.00 06/21/2017
Fees Total Due: ¤0.00 Total Paid: ¤505.80