I want to search for...

Permit #2017051202

Permit Details

Status: COED

Parcel Id: 08-12-31-0650-000B0-0110
Total Square Footage: 0 sqft
Block: 000B0
Subdivision: -
Job Phone: (386)763-4190
Location Address: 2 MCCORMICK DR
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 07/11/2017
NOC: RECORDED
Applicant name: PAUL KEITH CULVER
Owner: HINMAN II, ROY H

Address

31 ISLAND ESTATES PARKWAY

PALM COAST, FL 32137

Lot: 0110
Contracted Stated Job Value: ¤250,000.00
Job Description: ISLAND DOCTORS - INTERIOR RENOVATION
Type: CN

Contractor

PAUL CULVER CONSTRUCTION INC
Status Location Address State License Number Phone Fax
ACTIVE

1301 BEVILLE RD SUITE #6

DAYTONA BEACH, FL 32119

CGC059149 (Exp: 08/31/2026) (386)763-4190 (386)322-6724

Sub Contractors

JAMES KUYKENDALL
Status Location Address State License Number Phone Fax
CANCEL

2550 US 1 NORTH SUITE 3

BUNNELL, FL 32110

CAC1815546 (Exp: 08/31/2022) (386)437-2929 (386)437-2942
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
BRETT FORREST L'AMIE
Status Location Address State License Number
INACTIVE

919 VALENCIA ROAD

SOUTH DAYTONA, FL 32119

CFC1428647 (Exp: 08/31/2026)
ANDY JOHNSTON
Status Location Address State License Number Phone Fax
INACTIVE

887 BRENTWOOD DRIVE

DAYTONA BEACH, FL 32117

1944870002010 (Exp: 06/30/2026) 386-252-7407 386-898-0322
ROBERT F JARVIS JR
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

2922 HOWLAND BLVD

Deltona, FL 32725

SUITE 3

Deltona, FL 32725

EF0000527 (Exp: 08/31/2018) (386) 789-5555 386-789-9858

Inspection History

Type Request Date Result Inspector
FIRE FINAL 10/13/2017 FINAL APPROVED WMILLER
U - UTILITY COMMERCIAL FINAL 10/13/2017 FINAL APPROVED JNICHOLS
Note: THIS IS A REINSPECTION
HVAC FINAL 10/12/2017 APPROVED CMINI
BUILDING FINAL 08/30/2017 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION. need to remove dumpster, check on HVAC AND FIRE FINAL
BUILDING FINAL 08/29/2017 Disapproved -FEE REQUIRED CMINI
Note: missing ADA counter at 36" , emergency light not working in ADA unisex bath. missing door levers. missing bathroom identification signs.
ELECTRIC FINAL 08/29/2017 APPROVED RMARTIN
PLUMBING FINAL 08/29/2017 APPROVED JGIBSON
HVAC FINAL 08/29/2017 Disapproved - NO FEE CMINI
Note: SECTION 606 SMOKE DETECTION SYSTEMS CONTROL 606.1 Controls required. Air distribution systems shall be equipped with smoke detectors listed and labeled for installation in air distribution systems, as required by this section. Duct smoke detectors shall comply with UL 268A. Other smoke detectors shall comply with UL 268. 606.2 Where required. Smoke detectors shall be installed where indicated in Sections 606.2.1 through 606.2.3
U - UTILITY COMMERCIAL FINAL 08/29/2017 CANCELLED BY APPLICANT MBACON
Note: Not ready
HVAC ROUGH 08/25/2017 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
ABOVE CEILING 08/25/2017 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
INSULATION 08/25/2017 APPROVED JHINDMAN
FRAMING 08/03/2017 APPROVED JHINDMAN
ABOVE CEILING 08/03/2017 Disapproved - NO FEE JHINDMAN
Note: 1. provide approved mechanical plans 5th ed. FBC 107.4
HVAC ROUGH 08/03/2017 Disapproved -FEE REQUIRED JHINDMAN
Note: 1. provide approved mechanical plans 5th ed. FBC 107.4
PLUMBING 2ND ROUGH 08/03/2017 APPROVED JGIBSON
PLUMBING 1ST ROUGH 07/19/2017 APPROVED - AS NOTED JGIBSON
Note: THIS IS A REINSPECTION NEED REVISION ON THE USE OF''AAV'' IN LUEI OF ''VTR'' AND WHICH SINK IN''ADA'' BATH IS USED OR BOTH
PLUMBING 2ND ROUGH 07/19/2017 CANCELLED BY APPLICANT AIRS WEB
ELECTRIC 2ND ROUGH 07/19/2017 APPROVED RMARTIN
PLUMBING 1ST ROUGH 07/13/2017 Disapproved -FEE REQUIRED JGIBSON
Note: MISSING 10' HEAD PRESSUER, NEED TO HAVE HARD CAPS ON DELETED LINES IN FLOOR AREAS, ''ADA'' BATH ROOM NOT WET VENTED, PLANS CALL FOR TYPE ''M'' AND ''L'' COPPER NEED REVISION TO SHOW USE OF CPVC IN LUEI OF COPPER PER PLAN, ALSO PLAN CALLS FOR WATER TO BE RAN OVERHEAD CPVC HAS BEEN INSTALLED UNDER GROUND CHECK WITH ENGINEER FOR APPROVAL

Review History

Department Status Date In Date Out
MECH COMPLETE 08/24/2017 08/24/2017
Note: Released By: FREODICA Revision: Changed hvac duct layout.
MECH HOLD 08/14/2017 08/22/2017
Note: Held By: FREODICA REVISION Provide the distributed supply air in CFM's of AHU-2 and AHU-3 on the revised hvac plan and have the signature and license number of hvac contractor per FBC 5th ed. 105.3.1.2.. F.Reodica -386-986-4734.
PLUM COMPLETE 07/27/2017 08/02/2017
Note: Released By: FREODICA Changed plumbing plans P-1 & P-2 and riser diagram.
PLUM COMPLETE 07/19/2017 07/19/2017
Note: Released By: FREODICA Revision: 1. Changed type M copper to CPVC. 2. Changed piping insulation from fiberglass to neoprene.
MECH COMPLETE 06/28/2017 07/05/2017
PLUM COMPLETE 06/28/2017 07/05/2017
BLD COMPLETE 05/31/2017 06/06/2017
ELEC COMPLETE 05/31/2017 06/06/2017
Note: A seperate permit is required for the Fire Alarm work.
FI1 COMPLETE 05/31/2017 06/06/2017
MECH HOLD 05/31/2017 06/06/2017
Note: 1. Provide separate existing hvac plan and separate proposed hvac plan as only one(1) hvac plan (M-1) was submitted and it does not specify if it is new or existing per FBC 5th ed. 107.2.1. 2. Provide scope of work and coordinate the hvac plan with architectural plan (A-1). Almost 1/3 of architectural floor plan indicates not in contract (NIC) but hvac plan M-1) shows more spaces not even shown on architectural plan. FBC 5th ed. 107.2.1. 3. Provide outdoor air duct layout and location outdoor unit (condenser) per FBCM 403.3/107.2.1. F.Reodica - 386-986-4734.
PLUM HOLD 05/31/2017 06/06/2017
Note: Provide service sink per FBCP 5th ed,403. F.Reodica - 386-986-4734.
UD1 COMPLETE 05/31/2017 06/01/2017
ZON COMPLETE 05/31/2017 06/01/2017

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 10/10/2017
REVISION ¤40.00 08/25/2017
REINSPECTION FEE ¤40.00 08/25/2017
REVISION ¤40.00 08/02/2017
REVISION ¤40.00 08/02/2017
REINSPECTION FEE ¤40.00 07/17/2017
SITE PLAN 20 ¤20.00 07/11/2017
SURCHARGE FS 533.721 ¤14.96 07/11/2017
SURCHARGE - FS 468.631 ¤14.96 07/11/2017
ADMIN COMMERCIAL ¤60.00 07/11/2017
INSPECTION - COMMERCIAL ADD ¤1,750.00 07/11/2017
ELECTRIC FEE ¤210.00 07/11/2017
MECHANICAL FEE ¤210.00 07/11/2017
PLAN CHECK FEE ¤287.50 07/11/2017
PLUMBING FEE ¤210.00 07/11/2017
Fees Total Due: ¤0.00 Total Paid: ¤3,017.42