Permit #2017070104
Permit Details
Status: COED
| Parcel Id: 07-11-31-7009-00100-0280 |
| CONDITIONED SPACE: 2546 sqft |
| GARAGE: 521 sqft |
| OPENED PORCH (WITH ROOF) : 320 sqft |
| OPENED PORCH (WITH ROOF) : 90 sqft |
| Total Square Footage: 3477 sqft |
| Block: 00100 |
| Subdivision: 2208 - SECTION 9-FLORIDA PARK |
| Job Phone: (386)446-5161 |
| Location Address: 3 FARMDALE LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/27/2017 |
| NOC: RECORDED |
| Applicant name: HUGO A CAMACHO |
| Owner: IDEAL HOMES HOLDINGS LLC |
|
Address PO BOX 353639 PALM COAST, FL 32135 |
| Lot: 0280 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
IDEAL HOMES AT PALM COAST, INC.
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO BOX 353639 PALM COAST, FL 32137 |
CBC1250774 (Exp: 08/31/2026) | (386)446-5161 | (386)447-0238 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
THOMAS A REGULA
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
11320 PHILLIPS PKWY DRIVE E JACKSONVILLE, FL 32256 |
CMC1250075 (Exp: 08/31/2026) | 904-278-0339 | 904-278-0366 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
JOANNA S REELEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
2 MARKET PLACE D PALM COAST, FL 32137 |
CCC1327485 (Exp: 08/31/2020) | 386-445-7945 |
BOB BELL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
3200 PARKER DRIVE ST AUGUSTINE, FL 32084 |
LG35711 (Exp: 08/31/2027) | 904-417-6470 | 877-566-4016 |
Inspection History
| Type | Request Date | Result | Inspector |
| GAS FINAL | 05/02/2018 | APPROVED | CMINI |
| BLD - BUILDING FINAL | 05/02/2018 | FINAL APPROVED | CMINI |
| ROW - FINAL APRON (AFTER POUR) | 05/02/2018 | APPROVED | RGROSS |
| ROW - FINAL INSPECTION | 05/02/2018 | APPROVED | RGROSS |
| U -UTILITY RESIDENTIAL FINAL | 05/02/2018 | FINAL APPROVED | JNICHOLS |
| FINAL SURVEY (OFFICE USE ONLY) | 05/01/2018 | APPROVED | DREWIS |
| GAS ROUGH | 04/11/2018 | APPROVED | JGIBSON |
| GAS ROUGH | 04/04/2018 | Disapproved - NO FEE | JGIBSON |
| Note: NEED ALL PAPER WORK MISSING RISER FOR GAS, AND SUB - CONTRACTOR FOR GAS LISTED ON PERMIT | |||
| ELECTRIC - EARLY POWER | 03/29/2018 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO DELL FPL RELEASED EARLY POWER 4:15 | |||
| ROW- PRE-APRON (PRE-POUR) | 03/20/2018 | APPROVED - AS NOTED | RGROSS |
| Note: READY FOR PAVERS. NOTED THAT HEAVY RAIN IN FORECAST. BE SURE TO RECOMPACT IF ANY WASHOUTS OCCUR. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/09/2018 | PARTIALLY APPROVED | RGROSS |
| Note: APPROVED FOR CONCRETE OVER BOTH CULVERTS ONLY. PAVER RESTRAINT FOOTER NOT PREPARED. | |||
| U - SEWER TIE IN | 03/06/2018 | APPROVED | JNICHOLS |
| GRAVITY SEWER TEST | 03/06/2018 | APPROVED | JGIBSON |
| GAS ROUGH | 02/05/2018 | Disapproved - NO FEE | WMILLER |
| Note: THIS IS A REINSPECTION IN HOUSE GAS ROUGH PASSED (CALL ROUGH IN AGAIN WHEN TANK AND EXTERIOR LINES HAVE BEEN PLACED, PRIOR TO GAS FINAL) | |||
| INSULATION | 02/05/2018 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 02/01/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: DID NOT CORRECT THE FOLLOWING DEFICIENCIES NOTED PRIOR BY CM. AND DRYWALL HAS BEEN STACKED SO THAT NOT ALL DEFICIENT LOCATIONS CAN BE SEEN (REMOVE/MOVE DRYWALL) need to adjust in both bedrooms and dining room required outlet spacing 6' with in openings 210.52 need to strap service cable in attic every 4-1/2' NEC.334.30 ALSO NEED FIRE FOAM AT ALL TOP PLATE PENITRATIONS FOR GAS RISERS IN MASTER BEDROOM, KITCHEN, AND LAUNDRY. NEED FIRE BLOCKING AT DROP CEILING LOCATIONS AT RIGHT SIDE OF ENTRY, LEFT SIDE OF ENTRY TO MASTER SUITE, AND PANTRY. | |||
| GAS ROUGH | 02/01/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. TAG GAUGE WITH PRESSURE APPLIED FOR INSPECTION 2. ELEC BONDING OF GAS PIPE RESIDENTIAL G2411.1 AND 2411.1.1 3. FIREBLOCKING R302.11 (4) PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVEL (WITH APPROVED MATERIAL).... AT ALL TOP PLATE LOCATIONS) 4. STRAPS: SUPPORT OF PIPING EVERY 4 19 REQUIRED EVERY 6 19 FOR CSST. FBCG 2424 | |||
| LATH/BRICK/ WATER BARRIER | 01/24/2018 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 01/23/2018 | Disapproved -FEE REQUIRED | WMILLER |
| Note: DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL | |||
| ALL ROUGH | 01/16/2018 | APPROVED - AS NOTED | CMINI |
| Note: need to adjust in both bedrooms and dining room required outlet spacing 6' with in openings 210.52 need to strap service cable in attic every 4-1/2' NEC.334.30 | |||
| ROOF VALLEY & METAL | 12/27/2017 | APPROVED | WMILLER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/28/2017 | APPROVED | WMILLER |
| ELECTRIC-TUG | 11/13/2017 | APPROVED | WMILLER |
| Note: TALKED TO DEL AT FPL | |||
| FOUND SURVEY APPROVED (OFFICE) | 11/08/2017 | APPROVED | FREODICA |
| TIE BEAM / LINTEL | 11/08/2017 | APPROVED | CMINI |
| MONOLITHIC SLAB | 10/04/2017 | APPROVED | CMINI |
| PLUMBING 1ST ROUGH UNDERGROUND | 09/26/2017 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 04/30/2018 | 05/01/2018 |
| Note: Released By: DREWIS | |||
| SW1 | HOLD | 04/26/2018 | 04/27/2018 |
| Note: Held By: DREWIS final s. Front right side elevation on property line of 18.50' and elevations on the back side/right corner allow flow onto the adjacent properties, Tech. Manual Sec. 5 Eng. Standard 300.01 A1 c6. Daniel Rewis 986-4736 | |||
| ZON | COMPLETE | 04/10/2018 | 04/10/2018 |
| Note: Released By: AMOBLEY | |||
| PLUM | COMPLETE | 04/05/2018 | 04/09/2018 |
| Note: Released By: FREODICA Revisiion: Changed gas riser diagram -added gas grill. | |||
| ZON | COMPLETE | 03/05/2018 | 03/06/2018 |
| Note: Released By: AMOBLEY | |||
| SW1 | COMPLETE | 02/26/2018 | 02/27/2018 |
| Note: Released By: DREWIS | |||
| ZON | COMPLETE | 02/26/2018 | 02/26/2018 |
| Note: Released By: AMOBLEY | |||
| PLUM | COMPLETE | 01/25/2018 | 01/29/2018 |
| Note: Released By: FREODICA Revision: added 250 gal u/g tank for 22 kw generator with gas riser diagram. | |||
| ZON | COMPLETE | 01/25/2018 | 01/25/2018 |
| Note: Released By: AMOBLEY | |||
| ELEC | COMPLETE | 01/25/2018 | 01/25/2018 |
| Note: Released By: DREWIS | |||
| SW1 | COMPLETE | 01/23/2018 | 01/25/2018 |
| Note: Released By: DREWIS | |||
| ZON | COMPLETE | 01/23/2018 | 01/23/2018 |
| Note: Released By: AMOBLEY | |||
| SW1 | COMPLETE | 11/06/2017 | 11/07/2017 |
| Note: Released By: FREODICA FOUNDATION S | |||
| BLD | COMPLETE | 09/19/2017 | 09/22/2017 |
| Note: Released By: JHINDMAN | |||
| ZON | COMPLETE | 07/26/2017 | 07/26/2017 |
| Note: Released By: AMOBLEY | |||
| BLD | COMPLETE | 07/06/2017 | 07/11/2017 |
| Note: Released By: JHINDMAN | |||
| ELEC | COMPLETE | 07/06/2017 | 07/11/2017 |
| Note: Released By: JHINDMAN | |||
| ENGIN1 | COMPLETE | 07/06/2017 | 07/17/2017 |
| Note: Released By: TBAKER | |||
| MECH | COMPLETE | 07/06/2017 | 07/10/2017 |
| Note: Released By: FREODICA | |||
| PLUM | COMPLETE | 07/06/2017 | 07/10/2017 |
| Note: Released By: FREODICA | |||
| SW1 | COMPLETE | 07/06/2017 | 07/11/2017 |
| Note: Released By: JHINDMAN | |||
| UD1 | COMPLETE | 07/06/2017 | 07/07/2017 |
| Note: Released By: MBACON This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. | |||
| ZON | HOLD | 07/06/2017 | 07/07/2017 |
| Note: Held By: TAWILLIAMS Floor plan shows an office off of the nook area, but it isn't allowed. Landscaping: Need a minimum of 6 shrubs on left side of house (street side) T Williams 986.2655 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 05/03/2018 |
| REVISION | ¤40.00 | 05/03/2018 |
| REVISION | ¤40.00 | 05/03/2018 |
| REVISION | ¤40.00 | 05/03/2018 |
| REVISION | ¤40.00 | 05/03/2018 |
| REINSPECTION FEE | ¤40.00 | 05/03/2018 |
| REINSPECTION FEE | ¤40.00 | 05/03/2018 |
| REINSPECTION FEE | ¤40.00 | 05/03/2018 |
| NEW RESIDENTIAL INSPECTIONS | ¤640.00 | 07/27/2017 |
| ADMIN FEE | ¤20.00 | 07/27/2017 |
| SITE PLAN 20 | ¤20.00 | 07/27/2017 |
| SURCHARGE FS 533.721 | ¤15.64 | 07/27/2017 |
| SURCHARGE - FS 468.631 | ¤23.46 | 07/27/2017 |
| STORM WATER PERMIT FEES | ¤80.00 | 07/27/2017 |
| 3% TRANS IMPACT FEE CREDIT | (¤93.74) | 07/27/2017 |
| ELECTRIC FEE | ¤252.00 | 07/27/2017 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.56) | 07/27/2017 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤218.79 | 07/27/2017 |
| IMPACT FEE PARKS | ¤849.24 | 07/27/2017 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 07/27/2017 |
| RECORDING FEE REIMBURSE DOC | ¤52.50 | 07/27/2017 |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | 07/27/2017 |
| MECHANICAL FEE | ¤252.00 | 07/27/2017 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 07/27/2017 |
| PLAN CHECK FEE | ¤128.00 | 07/27/2017 |
| PLUMBING FEE | ¤252.00 | 07/27/2017 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,722.52 |