Permit #2017070378
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7006-00010-0270 |
| Block: 00010 |
| Subdivision: 2213 - SECTION 6-FLORIDA PARK |
| Job Phone: 386-503-0906 |
| Location Address: 66 FLEMING CT |
| Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION |
| Issue Date: 08/07/2017 |
| NOC: RECORDED |
| Applicant name: ANTHONY FALLONE |
| Owner: CAHL, LOUIS & FLORA A |
|
Address 66 FLEMING CT PALM COAST, FL 32137 |
| Lot: 0270 |
| Contracted Stated Job Value: ¤20,000.00 |
| Job Description: BATHROOM REMODEL/WINDOWS |
| Type: CN |
Contractor
FONTANA CONSTRUCTION, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P.O. BOX 351222 PALM COAST, FL 32137 |
CBC1250596 (Exp: 08/31/2022) | 386-503-0906 | (386)986-1305 |
Sub Contractors
JESSE E MORRIS
| Status | Location Address | State License Number | Phone |
| INACTIVE |
60 COPPER LANE PALM COAST, FL 32137 |
EC13007529 (Exp: 08/31/2018) | 847-815-2885 |
JOHN CHARLES GRAY
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2707 ANNETTE STREET FLAGLER BEACH, FL 32136 |
CFC1425975 (Exp: 08/31/2026) | (386)793-3690 | (386)439-7585 |
Inspection History
| Type | Request Date | Result | Inspector |
| TIE BEAM / LINTEL | 03/23/2018 | CANCELLED BY INSPECTOR | CMINI |
| Note: n/a | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/23/2018 | CANCELLED BY INSPECTOR | CMINI |
| Note: n/a | |||
| BLD - BUILDING FINAL | 03/23/2018 | FINAL APPROVED | CMINI |
| INSULATION | 11/02/2017 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION. need to install smoke detector per plan by final | |||
| ALL ROUGH | 11/02/2017 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION, need to install smoke detectors per plan by final | |||
| ALL ROUGH | 10/27/2017 | Disapproved -FEE REQUIRED | CMINI |
| Note: not ready for all rough, electric not complete per code and per plan. exhuast fan not installed. metal boxes not grounded. etc. | |||
| INSULATION | 10/27/2017 | Disapproved - NO FEE | CMINI |
| Note: block walls not insulated | |||
| MONOLITHIC SLAB | 10/10/2017 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB | 10/06/2017 | Disapproved -FEE REQUIRED | WMILLER |
| Note: NEED TO CLEAN OUT THE AREAS TO BE POURED. (DIRT UP THE SIDES WILL NOT ALLOW A FULL 4inch THICKNESS NEAR SIDES BY BACK WALL | |||
| DOWN CELL | 10/04/2017 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 10/02/2017 | APPROVED - AS NOTED | JGIBSON |
| Note: NEED TO CAP OFF EXISISTING 2'' VENT IN ATTIC SPACE BY WHERE OLD BATHROOM WAS WITH 2'' HARD CAP WATER LINES WILL BE LOOKED AT ALROUGH | |||
| DOWN CELL | 10/02/2017 | Disapproved -FEE REQUIRED | CMINI |
| Note: masonry wall needs to have continuous load path per plan and per code, need to have overlap on bar of a min 30 required. table 1807.1.6.3(4) and plans calling for steel to be epoxied into footer. both windows |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 07/21/2017 | 07/27/2017 |
| Note: Released By: JHINDMAN | |||
| BLD | HOLD | 07/20/2017 | 07/20/2017 |
| Note: Held By: FREODICA 1. Florida product approval FL 11354.1 for the exterior door can not be found on code version 2014 . Clarify per FBC 5tth ed. 107.2.1. 2. Florida product approval FL 1844.5 for the windows with model HR 5410 does not match with the model descrioption on code version 2014. Clarify per FBC 5th ed. 107.2.1. F.Reodica -386-986-4734. | |||
| ELEC | COMPLETE | 07/13/2017 | 07/18/2017 |
| Note: Released By: JHINDMAN | |||
| PLUM | COMPLETE | 07/13/2017 | 07/20/2017 |
| Note: Released By: FREODICA |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 03/23/2018 |
| REINSPECTION FEE | ¤40.00 | 03/23/2018 |
| REINSPECTION FEE | ¤40.00 | 03/23/2018 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 08/07/2017 |
| SITE PLAN 20 | ¤20.00 | 08/07/2017 |
| SURCHARGE FS 533.721 | ¤2.64 | 08/07/2017 |
| SURCHARGE - FS 468.631 | ¤3.96 | 08/07/2017 |
| ADMIN FEE | ¤20.00 | 08/07/2017 |
| ELECTRIC FEE | ¤72.00 | 08/07/2017 |
| PLAN CHECK FEE | ¤40.00 | 08/07/2017 |
| PLUMBING FEE | ¤72.00 | 08/07/2017 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤390.60 |