Permit #2017080941

Permit Details

Status: COED

Parcel Id: 07-11-31-7029-00540-0220
CONDITIONED SPACE: 1596 sqft
GARAGE: 411 sqft
OPENED PORCH (WITH ROOF) : 20 sqft
OPENED PORCH (WITH ROOF) : 154 sqft
Total Square Footage: 2181 sqft
Block: 00540
Subdivision: 2209 - SECTION 29-ROYAL PALMS
Job Phone: 386-236-4133
Location Address: 165 RYAN DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/06/2017
NOC: RECORDED
Applicant name: LEONARDO CIRO SANCLEMENTE
Owner: BEAL, STEVEN & BEVERLY

Address

71 PHEASANT DR

PALM COAST, FL 32164

Lot: 0220
Contracted Stated Job Value: ¤200,628.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INTERVEST CONSTRUCTION, INC.
Status Location Address State License Number Phone
CANCEL

2379 BEVILLE RD

DAYTONA BEACH, FL 32119

CBC1261237 (Exp: 08/31/2020) 386-236-4133

Sub Contractors

STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
ROBERT CRAIG KULP
Status Location Address State License Number Phone
CANCEL

5401 ENERGY AIR CT

ORLANDO, FL 32810

CAC1816317 (Exp: 08/31/2022) 407-886-3729
JEFFREY DALE KNIGHT
Status Location Address State License Number Phone Fax
INACTIVE

923 ASHMEADE CT

PORT ORANGE, FL 32127

CFC057351 (Exp: 08/31/2026) 386-345-3857 386-345-4443
BARRY D MARTIN
Status Location Address State License Number Phone Fax
CANCEL

1650 N STATE STREET

Bunnell, FL 32110

CCC033728 (Exp: 08/31/2020) (386) 437-7700 (386)437-7701

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 03/16/2018 FINAL APPROVED KHOWELL
Note: THIS IS A REINSPECTION
ROW - FINAL INSPECTION 03/15/2018 APPROVED - AS NOTED KHOWELL
Note: THIS IS A REINSPECTION CONTRACTOR IS LAYING SOD TODAY IN THE DISTURBED AREAS. WILL REINSPECT DURING THE FINAL APRON
ROW - FINAL INSPECTION 03/14/2018 Disapproved -FEE REQUIRED KHOWELL
Note: THIS IS A REINSPECTION CLEAN THE CONCRETE REMANTS OUT OF THE R.O.W. AND FINISH SODDING R.O.W. BOTH SIDE OF ROAD THAT WAS DISTURBED PER PALM COAST FL. CODE OF ORDINANCES SEC. 42-52 C. SEED AND STRAW NOT ALLOWED IN THE R.O.W. SOD ONLY IN KIND. ALSO SWALE PLAN NEEDS TO BE ON SITE
U -UTILITY RESIDENTIAL FINAL 03/14/2018 FINAL APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION
U -UTILITY RESIDENTIAL FINAL 03/06/2018 Disapproved -FEE REQUIRED LFITZGERALD
Note: Pep tank clean out cap required to be flush with sod grade,not at a 45 angle
ROW - FINAL APRON (AFTER POUR) 03/06/2018 Disapproved - NO FEE KHOWELL
Note: CHECK TO MAKE SURE THERE IS NO CONCRETE IN CULVERT PIPE, SEE NOTES IN THE R.O.W. FINAL ALSO.
ROW - FINAL INSPECTION 03/06/2018 Disapproved -FEE REQUIRED KHOWELL
Note: CLEAN TRASH OUT OF ADJOINING VACANT LOTS, SEED AND STRAW DISTURBED AREA AT REAR OF PROPERTY AND ADJACENT LOT, SOD ANY DISTURBED R.O.W. IN KIND AND ACROSS THE ROAD CUT IN TO MATCH EXISTING GRADE. REMOVE EXPANSION JOINT MATERIAL ALONG APRON AND REPAIR DAMAGED ASPHALT PAVEMENT WITH PERMINANT PAVEMENT
BLD - BUILDING FINAL 03/06/2018 FINAL APPROVED DROCKWELL
FINAL SURVEY (OFFICE USE ONLY) 03/05/2018 APPROVED JHINDMAN
ROW - FINAL APRON (AFTER POUR) 02/26/2018 Disapproved - NO FEE CTROHA
Note: NEED FINAL SURVEY APPROVED FOR THIS INSPECTION
GRAVITY SEWER TEST 02/09/2018 APPROVED JGIBSON
U - SEWER TIE IN 02/09/2018 APPROVED MBACON
ELECTRIC - EARLY POWER 02/07/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 3:45
ROW- PRE-APRON (PRE-POUR) 02/07/2018 APPROVED - AS NOTED CTROHA
Note: FORMS AT THE ROAD EDGE NEED CORRECTED. END OF DRIVEWAY NEEDS TO BE NO MORE THAN 2" AWAY FROM ROAD EDGE READY TO POUR It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete.
INSULATION 12/27/2017 CANCELLED BY APPLICANT AIRS WEB
INSULATION 12/27/2017 APPROVED WMILLER
LATH/BRICK/ WATER BARRIER 12/27/2017 APPROVED WMILLER
ALL ROUGH 12/15/2017 APPROVED - AS NOTED DROCKWELL
Note: Nail plate for sink drain bottom plate hallway entry
ROOF VALLEY & METAL 12/13/2017 FINAL APPROVED DROCKWELL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/06/2017 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/01/2017 Disapproved -FEE REQUIRED DROCKWELL
Note: Not ready for inspection.Structural work not completed
TIE BEAM / LINTEL 11/17/2017 APPROVED WMILLER
FOUND SURVEY APPROVED (OFFICE) 11/16/2017 APPROVED DREWIS
MONOLITHIC SLAB 11/08/2017 APPROVED DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 11/03/2017 APPROVED - AS NOTED JGIBSON
Note: NEED REVISION FOR USE OF''AAV'' IN MASTER BATH LAV. AREA RISER SHOWS ''VTR''. HAVE ON SITE BEFORE LINTEL INSPECTION

Review History

Department Status Date In Date Out
SW1 COMPLETE 03/01/2018 03/05/2018
Note: Released By: JHINDMAN final s
SW1 COMPLETE 11/16/2017 11/16/2017
Note: Released By: DREWIS found survey
PLUM COMPLETE 11/03/2017 11/09/2017
Note: Released By: FREODICA Revision: changed sanitary riser diagram
ZON COMPLETE 09/27/2017 09/28/2017
Note: Released By: TAWILLIAMS
UD1 COMPLETE 09/27/2017 09/29/2017
Note: Released By: MBACON This is a PEP Tank area. The Pep Panel will be placed 5 feet from the front corner of the building on the same side of the building as the PEP tank that is marked on the Utility marked Site plan. Make sure the electrician places the PEP power wire between 3 feet and 5 feet from the ground. The plumber should exit the slab with the sewer pipe on the side of the building the tank will be on and matching the utility marked site plan, this will reduce any piping under driveways or sidewalks and minimize the fall required. The sewer tie-in inspection must be called in the day before the tie-in. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in visual inspection so he can witness the tie-in. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
MECH COMPLETE 09/27/2017 09/29/2017
Note: Released By: FREODICA
SW1 COMPLETE 09/27/2017 10/02/2017
Note: Released By: DREWIS
BLD COMPLETE 08/24/2017 08/28/2017
Note: Released By: FREODICA
ELEC COMPLETE 08/24/2017 09/01/2017
Note: Released By: JHINDMAN
ENGIN1 COMPLETE 08/24/2017 09/07/2017
Note: Released By: TBAKER
MECH HOLD 08/24/2017 08/28/2017
Note: Held By: FREODICA Provide signature and license number of hvac contractor on hvac plan per FBC 5th ed. 105.3.1.2. F.Reodica-386-986-4734.
PLUM COMPLETE 08/24/2017 08/28/2017
Note: Released By: FREODICA
SW1 HOLD 08/24/2017 09/01/2017
Note: Held By: JHINDMAN 1.Provide a proposed drainage plan that includes the following. The elevations on all adjacent properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. The elevations at 20 foot intervals along all property lines. The interior elevations at no greater than a 20 foot grid. per ch.5 ULDC Technical manual. 2. the grade at the house shall fall 6" within the first 10 ft. 5th edition FBC Residential 401.3.
UD1 HOLD 08/24/2017 08/25/2017
Note: Held By: MBACON PEP Panel is not shown in the electrical plan. Submit a new electrical plan showing PEP Panel on the building on the same side of the building as indicated in the Utility marked site plan.
ZON HOLD 08/24/2017 08/24/2017
Note: Held By: AMOBLEY Per the LDC there shall be one tree for each 2500 square feet. Pine trees are not considered a credited tree

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 03/15/2018
REINSPECTION FEE ¤40.00 03/15/2018
REINSPECTION FEE ¤40.00 03/15/2018
REINSPECTION FEE ¤40.00 03/15/2018
REVISION ¤40.00 03/15/2018
SITE PLAN 20 ¤20.00 10/06/2017
SURCHARGE FS 533.721 ¤10.63 10/06/2017
SURCHARGE - FS 468.631 ¤15.94 10/06/2017
STORM WATER PERMIT FEES ¤80.00 10/06/2017
3% TRANS IMPACT FEE CREDIT (¤93.74) 10/06/2017
NEW RESIDENTIAL INSPECTIONS ¤401.26 10/06/2017
ADMIN FEE ¤20.00 10/06/2017
ELECTRIC FEE ¤180.38 10/06/2017
3% FIRE IMPACT FEE CREDIT (¤6.56) 10/06/2017
IMPACT FEE FIRE NONRESIDENTIAL ¤218.79 10/06/2017
IMPACT FEE PARKS ¤849.24 10/06/2017
IMPACT FEE SCHOOL ¤3,600.00 10/06/2017
IMPACT FEE TRANSPORTATION ¤3,124.67 10/06/2017
MECHANICAL FEE ¤180.38 10/06/2017
3% PARKS IMPACT FEE CREDIT (¤25.48) 10/06/2017
PLAN CHECK FEE ¤80.25 10/06/2017
PLUMBING FEE ¤180.38 10/06/2017
Fees Total Due: ¤0.00 Total Paid: ¤9,036.14