Permit #2017081119

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-01420-0010
CONDITIONED SPACE: 2719 sqft
GARAGE: 768 sqft
OPENED PORCH (WITH ROOF) : 439 sqft
OPENED PORCH (WITH ROOF) : 58 sqft
Total Square Footage: 3984 sqft
Block: 01420
Subdivision: 2176 - SECTION 37-LAKEVIEW
Job Phone: (386)931-1917
Location Address: 47 LEMA LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/26/2017
NOC: RECORDED
Applicant name: BRAD MICHAEL THOMAS
Owner: MORRISON MICHAEL P & KIMBERLY A

Address

11 BIRCHWOOD PLACE

PALM COAST, FL 32137

Lot: 0010
Contracted Stated Job Value: ¤364,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

AUBURN HOMES INC.
Status Location Address State License Number Phone
HOLD

1 HARGROVE GRADE STE 1E

PALM COAST, FL 32137

CGC1506292 (Exp: 08/31/2020) (386)931-1917

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
JOHN ROBERT BLEVINS JR
Status Location Address State License Number Phone Fax
ACTIVE

17 PORWYN LANE

PALM COAST, FL 32164

CAC1816125 (Exp: 08/31/2026) 386-585-8283 386-263-2096
HEATH EDWARD SANFORD
Status Location Address State License Number Phone Fax
ACTIVE

1351 HAZELNUT ST

BUNNELL, FL 32110

CFC1427527 (Exp: 08/31/2026) 386-445-2532 386-445-5575
BARRY D MARTIN
Status Location Address State License Number Phone Fax
CANCEL

1650 N STATE STREET

Bunnell, FL 32110

CCC033728 (Exp: 08/31/2020) (386) 437-7700 (386)437-7701

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 07/19/2018 FINAL APPROVED JCOLASANTI
U -UTILITY RESIDENTIAL FINAL 07/19/2018 FINAL APPROVED JNICHOLS
ROW - FINAL INSPECTION 07/06/2018 APPROVED RGROSS
U -UTILITY RESIDENTIAL FINAL 07/06/2018 CANCELLED BY APPLICANT MBACON
ROW - FINAL APRON (AFTER POUR) 07/06/2018 APPROVED RGROSS
FINAL SURVEY (OFFICE USE ONLY) 06/19/2018 APPROVED DREWIS
ELECTRIC - EARLY POWER 05/15/2018 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED EARLY POWER 2:45
U - SEWER TIE IN 05/09/2018 APPROVED JNICHOLS
ROW- PRE-APRON (PRE-POUR) 05/07/2018 APPROVED RGROSS
Note: READY TO POUR
U - SEWER TIE IN 04/27/2018 Disapproved -FEE REQUIRED DSPENCER
Note: cleanout behind tank does not meet palm coast standards - no tee behind the tank allowed must use a Wye with a 45 for stack pipe that allows cleaning/routing to go one way to tank. replace and call for inspection when ready
GRAVITY SEWER TEST 04/27/2018 APPROVED JGIBSON
INSULATION 03/02/2018 APPROVED JCOLASANTI
ALL ROUGH 02/26/2018 APPROVED JCOLASANTI
LATH/BRICK/ WATER BARRIER 02/26/2018 APPROVED JCOLASANTI
ALL ROUGH 02/23/2018 Disapproved -FEE REQUIRED JCOLASANTI
Note: METAL BOXES SHALL BE GROUNDED NEC.314.4....NAIL PLATES ON ELECTRIC NEC.300.4.... provide 10 test pressure on waste lines. 5th ed. FBC R P2503.5.1. 2 ..JOINTS AND CONNECTIONS IN THE DWV SYSTEM SHALL BE GAS TIGHT AND WATER TIGHT FOR THE INTENDED USE OR PRESSURE REQUIRED BY TEST FBC 312. (tub needs to have water for test.) fireblocking needed for kitchen wall (ALL MARKED ON ELEC. PLANS)
ALL ROUGH 02/22/2018 CANCELLED BY APPLICANT JCOLASANTI
ROOF VALLEY & METAL 02/12/2018 APPROVED JCOLASANTI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/02/2018 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/30/2018 Disapproved -FEE REQUIRED JCOLASANTI
Note: THIS IS A REINSPECTION straps at lentel back right wall...tighten all-thread right and left bearing wall...h2.5 rafter to ridge..red head wood to masonry garage wall.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/26/2018 Disapproved -FEE REQUIRED JCOLASANTI
Note: numerous straps missing, need to srtrap valleys...need to complete inspection FBC 804
TIE BEAM / LINTEL 12/14/2017 APPROVED JCOLASANTI
FOUND SURVEY APPROVED (OFFICE) 11/14/2017 APPROVED DREWIS
MONOLITHIC SLAB 11/02/2017 APPROVED JCOLASANTI
PLUMBING 1ST ROUGH UNDERGROUND 10/27/2017 APPROVED JGIBSON

Review History

Department Status Date In Date Out
SW1 COMPLETE 06/18/2018 06/19/2018
Note: Released By: DREWIS final s
SW1 COMPLETE 11/13/2017 11/14/2017
Note: Released By: DREWIS foundation s
ZON COMPLETE 09/22/2017 09/25/2017
Note: Released By: TAWILLIAMS
MECH COMPLETE 09/22/2017 09/25/2017
Note: Released By: FREODICA
BLD COMPLETE 09/22/2017 09/25/2017
Note: Released By: FREODICA
ELEC COMPLETE 09/22/2017 09/26/2017
Note: Released By: DREWIS
SW1 COMPLETE 09/22/2017 09/26/2017
Note: Released By: DREWIS
BLD HOLD 08/30/2017 09/06/2017
Note: Held By: FREODICA Provide manufacturer's specifications of spry foam insulation for unvented attic and installation instructions per FBCR 5th ed. R316. F.Reodica -386-986-4734.
ELEC HOLD 08/30/2017 09/14/2017
Note: Held By: JHINDMAN 1. Provide the correct code reference ( 2011 NEC) on page E-1. J. Hindman 986-3784.
ENGIN1 COMPLETE 08/30/2017 09/14/2017
Note: Released By: TBAKER
MECH HOLD 08/30/2017 09/06/2017
Note: Held By: FREODICA Clarify the number of hvac units to be installed as energy calculations shows (1) unit but floor plan shows (2) condenser units per FBC 5th ed. 107.2.1. Freodica -386-986-4734.
PLUM COMPLETE 08/30/2017 09/06/2017
Note: Released By: FREODICA
SW1 HOLD 08/30/2017 09/14/2017
Note: Held By: JHINDMAN 1. Provide a grade with a minimum 6" fall on the right side of the house to the property line. 5th ed. FBC R 401.3. J. Hindman 986-3784.
UD1 COMPLETE 08/30/2017 09/01/2017
Note: Released By: MBACON This is a PEP Tank area. The Pep Panel will be placed 5 feet from the front corner of the building on the same side of the building as the PEP tank that is marked on the Utility marked Site plan. Make sure the electrician places the PEP power wire between 3 feet and 5 feet from the ground. The plumber should exit the slab with the sewer pipe on the side of the building the tank will be on and matching the utility marked site plan, this will reduce any piping under driveways or sidewalks and minimize the fall required. The sewer tie-in inspection must be called in the day before the tie-in. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in visual inspection so he can witness the tie-in. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON HOLD 08/30/2017 08/31/2017
Note: Held By: TAWILLIAMS A/C unit must be screened with 7 gallon schrubs on landscape plan

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 07/20/2018
REINSPECTION FEE ¤40.00 07/20/2018
REINSPECTION FEE ¤40.00 07/20/2018
REINSPECTION FEE ¤40.00 07/20/2018
IMPACT FEE FIRE NONRESIDENTIAL ¤218.79 07/20/2018
IMPACT FEE PARKS ¤849.24 07/20/2018
IMPACT FEE SCHOOL ¤3,600.00 07/20/2018
IMPACT FEE TRANSPORTATION ¤3,124.67 07/20/2018
CONTRACTOR CHANGE ¤40.00 07/20/2018
CONTRACTOR CHANGE ¤40.00 07/20/2018
ELECTRIC FEE ¤278.40 09/26/2017
ADMIN FEE ¤20.00 09/26/2017
MECHANICAL FEE ¤278.40 09/26/2017
PLAN CHECK FEE ¤145.60 09/26/2017
PLUMBING FEE ¤278.40 09/26/2017
NEW RESIDENTIAL INSPECTIONS ¤728.00 09/26/2017
SITE PLAN 20 ¤20.00 09/26/2017
SURCHARGE FS 533.721 ¤17.49 09/26/2017
SURCHARGE - FS 468.631 ¤26.23 09/26/2017
STORM WATER PERMIT FEES ¤80.00 09/26/2017
Fees Total Due: ¤0.00 Total Paid: ¤9,905.22