Permit #2017081119
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-01420-0010 |
| CONDITIONED SPACE: 2719 sqft |
| GARAGE: 768 sqft |
| OPENED PORCH (WITH ROOF) : 439 sqft |
| OPENED PORCH (WITH ROOF) : 58 sqft |
| Total Square Footage: 3984 sqft |
| Block: 01420 |
| Subdivision: 2176 - SECTION 37-LAKEVIEW |
| Job Phone: (386)931-1917 |
| Location Address: 47 LEMA LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/26/2017 |
| NOC: RECORDED |
| Applicant name: BRAD MICHAEL THOMAS |
| Owner: MORRISON MICHAEL P & KIMBERLY A |
|
Address 11 BIRCHWOOD PLACE PALM COAST, FL 32137 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤364,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
AUBURN HOMES INC.
| Status | Location Address | State License Number | Phone |
| HOLD |
1 HARGROVE GRADE STE 1E PALM COAST, FL 32137 |
CGC1506292 (Exp: 08/31/2020) | (386)931-1917 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
JOHN ROBERT BLEVINS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
17 PORWYN LANE PALM COAST, FL 32164 |
CAC1816125 (Exp: 08/31/2026) | 386-585-8283 | 386-263-2096 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1351 HAZELNUT ST BUNNELL, FL 32110 |
CFC1427527 (Exp: 08/31/2026) | 386-445-2532 | 386-445-5575 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/19/2018 | FINAL APPROVED | JCOLASANTI |
| U -UTILITY RESIDENTIAL FINAL | 07/19/2018 | FINAL APPROVED | JNICHOLS |
| ROW - FINAL INSPECTION | 07/06/2018 | APPROVED | RGROSS |
| U -UTILITY RESIDENTIAL FINAL | 07/06/2018 | CANCELLED BY APPLICANT | MBACON |
| ROW - FINAL APRON (AFTER POUR) | 07/06/2018 | APPROVED | RGROSS |
| FINAL SURVEY (OFFICE USE ONLY) | 06/19/2018 | APPROVED | DREWIS |
| ELECTRIC - EARLY POWER | 05/15/2018 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO DELL FPL RELEASED EARLY POWER 2:45 | |||
| U - SEWER TIE IN | 05/09/2018 | APPROVED | JNICHOLS |
| ROW- PRE-APRON (PRE-POUR) | 05/07/2018 | APPROVED | RGROSS |
| Note: READY TO POUR | |||
| U - SEWER TIE IN | 04/27/2018 | Disapproved -FEE REQUIRED | DSPENCER |
| Note: cleanout behind tank does not meet palm coast standards - no tee behind the tank allowed must use a Wye with a 45 for stack pipe that allows cleaning/routing to go one way to tank. replace and call for inspection when ready | |||
| GRAVITY SEWER TEST | 04/27/2018 | APPROVED | JGIBSON |
| INSULATION | 03/02/2018 | APPROVED | JCOLASANTI |
| ALL ROUGH | 02/26/2018 | APPROVED | JCOLASANTI |
| LATH/BRICK/ WATER BARRIER | 02/26/2018 | APPROVED | JCOLASANTI |
| ALL ROUGH | 02/23/2018 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: METAL BOXES SHALL BE GROUNDED NEC.314.4....NAIL PLATES ON ELECTRIC NEC.300.4.... provide 10 test pressure on waste lines. 5th ed. FBC R P2503.5.1. 2 ..JOINTS AND CONNECTIONS IN THE DWV SYSTEM SHALL BE GAS TIGHT AND WATER TIGHT FOR THE INTENDED USE OR PRESSURE REQUIRED BY TEST FBC 312. (tub needs to have water for test.) fireblocking needed for kitchen wall (ALL MARKED ON ELEC. PLANS) | |||
| ALL ROUGH | 02/22/2018 | CANCELLED BY APPLICANT | JCOLASANTI |
| ROOF VALLEY & METAL | 02/12/2018 | APPROVED | JCOLASANTI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/02/2018 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/30/2018 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: THIS IS A REINSPECTION straps at lentel back right wall...tighten all-thread right and left bearing wall...h2.5 rafter to ridge..red head wood to masonry garage wall. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/26/2018 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: numerous straps missing, need to srtrap valleys...need to complete inspection FBC 804 | |||
| TIE BEAM / LINTEL | 12/14/2017 | APPROVED | JCOLASANTI |
| FOUND SURVEY APPROVED (OFFICE) | 11/14/2017 | APPROVED | DREWIS |
| MONOLITHIC SLAB | 11/02/2017 | APPROVED | JCOLASANTI |
| PLUMBING 1ST ROUGH UNDERGROUND | 10/27/2017 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 06/18/2018 | 06/19/2018 |
| Note: Released By: DREWIS final s | |||
| SW1 | COMPLETE | 11/13/2017 | 11/14/2017 |
| Note: Released By: DREWIS foundation s | |||
| ZON | COMPLETE | 09/22/2017 | 09/25/2017 |
| Note: Released By: TAWILLIAMS | |||
| MECH | COMPLETE | 09/22/2017 | 09/25/2017 |
| Note: Released By: FREODICA | |||
| BLD | COMPLETE | 09/22/2017 | 09/25/2017 |
| Note: Released By: FREODICA | |||
| ELEC | COMPLETE | 09/22/2017 | 09/26/2017 |
| Note: Released By: DREWIS | |||
| SW1 | COMPLETE | 09/22/2017 | 09/26/2017 |
| Note: Released By: DREWIS | |||
| BLD | HOLD | 08/30/2017 | 09/06/2017 |
| Note: Held By: FREODICA Provide manufacturer's specifications of spry foam insulation for unvented attic and installation instructions per FBCR 5th ed. R316. F.Reodica -386-986-4734. | |||
| ELEC | HOLD | 08/30/2017 | 09/14/2017 |
| Note: Held By: JHINDMAN 1. Provide the correct code reference ( 2011 NEC) on page E-1. J. Hindman 986-3784. | |||
| ENGIN1 | COMPLETE | 08/30/2017 | 09/14/2017 |
| Note: Released By: TBAKER | |||
| MECH | HOLD | 08/30/2017 | 09/06/2017 |
| Note: Held By: FREODICA Clarify the number of hvac units to be installed as energy calculations shows (1) unit but floor plan shows (2) condenser units per FBC 5th ed. 107.2.1. Freodica -386-986-4734. | |||
| PLUM | COMPLETE | 08/30/2017 | 09/06/2017 |
| Note: Released By: FREODICA | |||
| SW1 | HOLD | 08/30/2017 | 09/14/2017 |
| Note: Held By: JHINDMAN 1. Provide a grade with a minimum 6" fall on the right side of the house to the property line. 5th ed. FBC R 401.3. J. Hindman 986-3784. | |||
| UD1 | COMPLETE | 08/30/2017 | 09/01/2017 |
| Note: Released By: MBACON This is a PEP Tank area. The Pep Panel will be placed 5 feet from the front corner of the building on the same side of the building as the PEP tank that is marked on the Utility marked Site plan. Make sure the electrician places the PEP power wire between 3 feet and 5 feet from the ground. The plumber should exit the slab with the sewer pipe on the side of the building the tank will be on and matching the utility marked site plan, this will reduce any piping under driveways or sidewalks and minimize the fall required. The sewer tie-in inspection must be called in the day before the tie-in. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in visual inspection so he can witness the tie-in. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. | |||
| ZON | HOLD | 08/30/2017 | 08/31/2017 |
| Note: Held By: TAWILLIAMS A/C unit must be screened with 7 gallon schrubs on landscape plan |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 07/20/2018 |
| REINSPECTION FEE | ¤40.00 | 07/20/2018 |
| REINSPECTION FEE | ¤40.00 | 07/20/2018 |
| REINSPECTION FEE | ¤40.00 | 07/20/2018 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤218.79 | 07/20/2018 |
| IMPACT FEE PARKS | ¤849.24 | 07/20/2018 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 07/20/2018 |
| IMPACT FEE TRANSPORTATION | ¤3,124.67 | 07/20/2018 |
| CONTRACTOR CHANGE | ¤40.00 | 07/20/2018 |
| CONTRACTOR CHANGE | ¤40.00 | 07/20/2018 |
| ELECTRIC FEE | ¤278.40 | 09/26/2017 |
| ADMIN FEE | ¤20.00 | 09/26/2017 |
| MECHANICAL FEE | ¤278.40 | 09/26/2017 |
| PLAN CHECK FEE | ¤145.60 | 09/26/2017 |
| PLUMBING FEE | ¤278.40 | 09/26/2017 |
| NEW RESIDENTIAL INSPECTIONS | ¤728.00 | 09/26/2017 |
| SITE PLAN 20 | ¤20.00 | 09/26/2017 |
| SURCHARGE FS 533.721 | ¤17.49 | 09/26/2017 |
| SURCHARGE - FS 468.631 | ¤26.23 | 09/26/2017 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/26/2017 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,905.22 |